- 05000327/LER-1981-118, Forwards LER 81-118/03L-0 + (ML20032A350)
- ML20032A352 + (ML20032A352)
- 05000327/LER-1981-118-03, /03L-0:on 810921,radiation Monitors for Containment Ventilation Were Out of Svc Simultaneously. Caused by Tech Spec Misinterpretation.Monitors Removed from Svc for Leak Testing of Containment Isolation Valves + (ML20032A353)
- AECM-81-418, Interim Deficiency Rept Re Loose Connections in Wiring, Improper Wire Crimps & Wire Size to Terminal Lug Size Discrepancies Initially Reported 810922.Investigation Underway.Final Rept by 811215 + (ML20032A354)
- ML20032A355 + (ML20032A355)
- 05000260/LER-1981-048, Forwards LER 81-048/03L-0 + (ML20032A357)
- ML20032A359 + (ML20032A359)
- ML20032A361 + (ML20032A361)
- IR 05000341/1981015 + (ML20032A363)
- ML20032A364 + (ML20032A364)
- 05000325/LER-1981-066, Forwards LER 81-066/03L-0 + (ML20032A365)
- 05000260/LER-1981-048-03, /03L-0:on 810921,during Normal Operation,Flow Totalizer FQ-68-5 Drifted High Causing Erroneous Flow Indication to Average Power Range Monitor Channels.Caused by Electronic Failure.Totalizer Replaced + (ML20032A367)
- ML20032A368 + (ML20032A368)
- ML20032A369 + (ML20032A369)
- ML20032A370 + (ML20032A370)
- ML20032A371 + (ML20032A371)
- 05000325/LER-1981-066-03, /03L-0:on 810925,while Running HPCI Sys Auxiliary Oil Pump in Accordance W/Surveillance Requirements,Local Insp Showed Pump Was Uncoupled from Motor.Caused by Misalignment of Coupling in Initial Unit Startup + (ML20032A372)
- ML20032A373 + (ML20032A373)
- ML20032A375 + (ML20032A375)
- 05000339/LER-1981-077, Forwards LER 81-077/03L-0 + (ML20032A379)
- IR 05000373/1981035 + (ML20032A381)
- ML20032A382 + (ML20032A382)
- ML20032A384 + (ML20032A384)
- 05000339/LER-1981-077-03, /03L-0:on 810920,axial Flux Difference Deviated Greater than 5% from Target for Max Duration of One Minute While Returning to Full Power Following Reactor Trip.Caused by Xenon Instability During Recovery from Reactor Trip + (ML20032A385)
- ML20032A389 + (ML20032A389)
- 05000324/LER-1981-103, Forwards LER 81-103/03L-0 + (ML20032A393)
- 05000266/LER-1981-015-01, /01T-0:on 811010,during Refueling Outage,High & Low Head Safety Injection Check Valve Leakage Test Indicated Excessive Leakage.Cause Not Stated.Affected Line Flushed & Passed Retest + (ML20032A396)
- ML20032A397 + (ML20032A397)
- 05000346/LER-1981-058, Forwards LER 81-058/01T-0 + (ML20032A398)
- 05000260/LER-1981-045, Forwards LER 81-045/03L-0 + (ML20032A401)
- 05000324/LER-1981-103-03, /03L-0:on 810921,primary Containment Atmospheric Oxygen analyzer,2-CAC-AT-1259-2,model F3M3,observed Showing Upscale Indication of Torus Oxygen Concentration.Caused by Moisture Buildup in Monitor Torus Sample Line + (ML20032A403)
- 05000334/LER-1981-082, Forwards LER 81-082/01T-0 + (ML20032A405)
- 05000285/LER-1981-009, Forwards LER 81-009/03L-0 + (ML20032A407)
- ML20032A409 + (ML20032A409)
- 05000260/LER-1981-045-03, /03L-0:on 810916,during Scram,When Manually Initiated,Hpci Gland Seal Condenser Upper Head Gasket Began Leaking.Caused by Head Gasket Stretching Out of Place Due to Overpressurization.Gasket Replaced + (ML20032A410)
- 05000321/LER-1981-106, Forwards LER 81-106/03L-0 + (ML20032A411)
- 05000285/LER-1981-009-03, /03L-0:on 810924,during Shutdown,Cooling Fan/Coil Placed in Svc for Containment Air Cooling.Pressurized Leak Developed When Coil End Plug Blew Out.Caused by Stripped Threads on Loosely Installed Thread End Plug + (ML20032A413)
- PNO-V-81-058, on 811025,during Insp of 4160-volt Switchgear Room,Fire Barrier Foam Matl Observed on Floor Near Electrical Cabinets.Caused by Failure During Installation to Seal Openings at Top of Cabinet + (ML20032A417)
- ML20032A418 + (ML20032A418)
- 1CAN108104, Forwards Emergency Feedwater Sys Upgrade Reliability Analysis + (ML20032A419)
- ML20032A421 + (ML20032A421)
- 05000321/LER-1981-106-03, /03L-0:on 810928,while Performing Diesel Generator Manual Start,Generator 1R43-S001B Started But Voltage Could Not Be Controlled W/Adjust Switch.Caused by Failure of Diodes in Voltage Regulator Circuit.Diodes Replaced + (ML20032A422)
- ML20032A424 + (ML20032A424)
- AECM-81-404, Final Deficiency Rept Re Discrepant Slopes in Instrument Process Tubing,Initially Reported on 801230.Also Reportable Per Part 21.Tubing Installations Have Been Redesigned.Specs Revised to Clarify Slope Requirements + (ML20032A427)
- ML20032A428 + (ML20032A428)
- 05000325/LER-1981-060, Updated LER 81-060/03L-1:on 810827 & 0915,reviews Revealed That Engineering Suppression Chamber Visual & Fire Protection Insps Were Not Performed within Tolerance Dates. Caused by Failure to Enter Insps in Master Schedule + (ML20032A430)
- ML20032A431 + (ML20032A431)
- ML20032A432 + (ML20032A432)
- ML20032A434 + (ML20032A434)
- ML20032A436 + (ML20032A436)
- ML20032A437 + (ML20032A437)