Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000321/LER-1981-102-03, /03L-0:on 810914,oil Leak Developed on Oil Sys. Caused by Torn Diaphragm on HPCI Robert Shaw Control Valve Resulting from Component Defect in Valve.Valve Replaced & New Diaphragm Installed + (ML20031F856)
- ML20031F857 + (ML20031F857)
- ML20031F858 + (ML20031F858)
- GO2-81-336, Interim Deficiency Rept Re Out of Calibr Torque Wrenches, Initially Reported 810814.Review of Special Requirements Checklist for Sampling Bolted Installations Performed.Next Rept by 811120 + (ML20031F860)
- 05000272/LER-1981-087, Forwards LER 81-087/04L-0.Detailed Event Analysis Encl + (ML20031F861)
- ML20031F863 + (ML20031F863)
- ML20031F864 + (ML20031F864)
- ML20031F865 + (ML20031F865)
- 05000272/LER-1981-087-04, /04L-0:on 810908,sea Turtles Removed from Circulating Water Sys Intake Trash Bars.Caused by Stressed Turtles Becoming Impinged on Bars.Trash Bars Will Be Observed & Cleaned When Necessary + (ML20031F869)
- IR 05000553/1981007 + (ML20031F870)
- ML20031F871 + (ML20031F871)
- ML20031F872 + (ML20031F872)
- 05000346/LER-1981-053, Forwards LER 81-053/01T-0 + (ML20031F874)
- 05000245/LER-1981-028, Forwards LER 81-028/03L-0.Detailed Event Analysis Encl + (ML20031F876)
- ML20031F878 + (ML20031F878)
- ML20031F879 + (ML20031F879)
- 05000346/LER-1981-053-01, /01T-0:on 810916,emergency Diesel Generator Tornado Missile Shield Discovered Missing from Doors 361 & 362 Following 810701 Turbocharger Changeout.Caused by Procedural Error.Shielding Replaced + (ML20031F880)
- 05000245/LER-1981-028-03, /03L-0:on 810811 During Gas Turbine Black Start Test,Generator Output Breaker Failed to Close,Preventing Output Voltage on Gas Turbine.Caused by Oxidation of Contacting Surfaces of Potentiometer.Surfaces Burnished + (ML20031F881)
- ML20031F882 + (ML20031F882)
- 05000366/LER-1981-090, Forwards LER 81-090/03L-0 + (ML20031F883)
- ML20031F885 + (ML20031F885)
- ML20031F886 + (ML20031F886)
- ML20031F888 + (ML20031F888)
- 05000366/LER-1981-090-03, /03L-0:on 810916,while Performing HNP-2-1500 for Primary Containment Atmospheric Control Sys,Standby Gas Treatment Discharge Damper Would Not Open Completely.Caused by Broken Valve Disc.Valve Replaced + (ML20031F889)
- ML20031F890 + (ML20031F890)
- ML20031F894 + (ML20031F894)
- ML20031F895 + (ML20031F895)
- ML20031F899 + (ML20031F899)
- ML20031F900 + (ML20031F900)
- IR 05000416/1981036 + (ML20031F902)
- ML20031F903 + (ML20031F903)
- ML20031F905 + (ML20031F905)
- ML20031F907 + (ML20031F907)
- ML20031F908 + (ML20031F908)
- ML20031F909 + (ML20031F909)
- ML20031F910 + (ML20031F910)
- TXX-3423, Submits Proposed Stress Limits to Be Used to Screen Steel Elbows for Acceptable Functional Capability,In Response to SER Open Item Re Functional Capability of ASME Code Class 2 & 3 Stainless Steel Elbows + (ML20031F912)
- ML20031F913 + (ML20031F913)
- ML20031F914 + (ML20031F914)
- 05000245/LER-1981-031, Forwards LER 81-031/03L-0.Detailed Event Analysis Encl + (ML20031F915)
- IR 05000225/1981004 + (ML20031F917)
- ML20031F918 + (ML20031F918)
- ML20031F922 + (ML20031F922)
- 05000245/LER-1981-031-03, /03L-0:on 810910,during Gas Turbine Emergency Fast Start Test,Gas Turbine Generator Output Field Breaker Failed to Close.Caused by Failure of Resistor to Open in Automatic Voltage Regulator Due to Oxide on Termination Lugs + (ML20031F923)
- ML20031F925 + (ML20031F925)
- ML20031F926 + (ML20031F926)
- 05000286/LER-1981-007, Forwards LER 81-007/01T-0.Detailed Event Analysis Encl + (ML20031F928)
- LD-81-070, Forwards Addl Response to NRC Questions on CESSAR-F, Chapter 3,re Capability of ASME Class 1,2 & 3 Piping Sys Omitted from + (ML20031F930)
- ML20031F931 + (ML20031F931)
- ML20031F932 + (ML20031F932)
- 05000293/LER-1981-049, Updated LER 81-049/01T-1:on 810828,discovered Water Bypass Condition in B RBCCW Heat Exchanger Will Be Installed.Caused by Water Erosion Due to Mussel Blockage Induced High Delta P.Design Change Repass Partition Plates + (ML20031F933)