Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20029C696 + (ML20029C696)
- ML20029C697 + (ML20029C697)
- 05000321/LER-1994-002-03, :on 940325,personnel Error Resulted in ESF Actuations.Personnel Counseled & Trained & EDG Control Circuit Wire Repaired + (ML20029C698)
- 05000213/LER-1994-009, :on 940328,automatic Reactor Trip Occurred While Performing Nop.Caused by Equipment Failure.Corrective Action:Procedure Rev & Repair/Reinstallment of Breaker 309-1A + (ML20029C699)
- 05000213/LER-1994-008, :on 940324,auxiliary Feedwater Hydraulic Control Sys Setpoints Found Low.Cause Under Investigation. Switches Recalibrated & Monitoring Increased + (ML20029C704)
- 05000263/LER-1994-001-01, :on 940323,missed Surveillance on SRV Low-Low Set Logic.Caused by Incorrect Surveillance Procedure Prerequisite.Corrective Action:Removed Incorrect Prerequisites,Trained on Procedure Review + (ML20029C706)
- ML20029C707 + (ML20029C707)
- ML20029C708 + (ML20029C708)
- 05000295/LER-1994-003-07, :on 940323,discovered That Sensing Lines on All of Safety Related Pressure Transmitters Were Capped Off. Cause Was Management/Qa Deficiency.Corrective Action: Removing Pipe Caps & Labeling Units + (ML20029C710)
- SNRC-2165, Submits Technical Info on Biological Shield Wall Blocks to Be Surveyed + (ML20029C711)
- ML20029C712 + (ML20029C712)
- ML20029C713 + (ML20029C713)
- ML20029C714 + (ML20029C714)
- B14801, Provides Response to NRC Request for Addl Info Re Individual Plant Exam,Per GL 88-20.Rev 0 to CY-PRA-93-022 Rept Encl + (ML20029C715)
- RA-93-022, Cy Containment Isolation Failure Probability + (ML20029C717)
- ML20029C718 + (ML20029C718)
- ML20029C720 + (ML20029C720)
- 05000298/LER-1992-020, :on 920130,containment Level Instruments Were Removed & re-installed Without Being Declared Inoperable. Caused by Personnel Failure to Follow Procedures.Operators Retrained + (ML20029C721)
- ML20029C722 + (ML20029C722)
- 05000245/LER-1994-011, :on 940322,RV Low Level Scram Setpoint & Low Level ECCS Setpoint Were Potentially Nonconservative.Caused by Failure of Plant Design.Setpoint Change Performed for Both Low Level Scram Setpoints + (ML20029C724)
- ML20029C725 + (ML20029C725)
- ML20029C726 + (ML20029C726)
- ML20029C727 + (ML20029C727)
- PY-CEI-NRR-1791, Responds to NRC Bulletin 93-002,Suppl 1, Debris Plugging of Emergency Core Cooling Suction Strainers + (ML20029C728)
- ML20029C729 + (ML20029C729)
- ML20029C730 + (ML20029C730)
- ML20029C731 + (ML20029C731)
- ML20029C733 + (ML20029C733)
- ML20029C734 + (ML20029C734)
- ML20029C735 + (ML20029C735)
- ML20029C736 + (ML20029C736)
- ML20029C737 + (ML20029C737)
- ML20029C738 + (ML20029C738)
- ML20029C739 + (ML20029C739)
- GO2-94-082, Forwards Amend to Rev 11 to Security Training & Qualification Plan.Amend Withheld + (ML20029C741)
- L-94-019, Forwards Rev 8 to Physical Security Plan.Rev Withheld,Per 10CFR2.790(a)(3) + (ML20029C742)
- NRC-94-0035, Responds to NRC Re Violations Noted in Insp Rept 50-341/93-02.Corrective Actions:Existing Sys Realigned to Allow Backflushing of Clogged Strainers + (ML20029C743)
- ML20029C744 + (ML20029C744)
- ML20029C746 + (ML20029C746)
- ML20029C747 + (ML20029C747)
- ML20029C749 + (ML20029C749)
- 05000354/LER-1994-001, :on 940305,ESF Actuation/Isolation & Loss of Shutdown Cooling Occurred.Caused by Personnel Error. Technician Counseled + (ML20029C750)
- ML20029C751 + (ML20029C751)
- ML20029C752 + (ML20029C752)
- NG-94-1391, Responds to NRC Bulletin 93-002,suppl 1, Debris Plugging of Emergency Core Cooling Suction Strainers + (ML20029C753)
- ML20029C755 + (ML20029C755)
- ML20029C756 + (ML20029C756)
- ML20029C757 + (ML20029C757)
- ML20029C761 + (ML20029C761)
- ML20029C762 + (ML20029C762)
- ML20029C763 + (ML20029C763)