- IR 05000282/1982021 + (ML20028C830)
- 05000311/LER-1982-151-03, /03L-0:on 821206,during Normal Operation, Containment Particulate Radioactivity Monitor Discovered Malfunctioning.Caused by Intermittent Connection on One Digital Component.Component Reseated + (ML20028C831)
- ML20028C832 + (ML20028C832)
- ML20028C833 + (ML20028C833)
- ML20028C834 + (ML20028C834)
- ML20028C835 + (ML20028C835)
- 05000220/LER-1982-017-03, /03L-0:on 821206,during Maint Outage,Leakage from Valves 68-06 & 68-09 Found Exceeding Tech Specs.Caused by Poor Seal Design.Mods Will Be Completed During Current Outage & Followed by Retest + (ML20028C836)
- ML20028C837 + (ML20028C837)
- ML20028C838 + (ML20028C838)
- 05000220/LER-1982-018-03, /03L-0:on 821207,during Maint Outage,Leakage from Valves 68-05 & 68-08 Found Exceeding Tech Specs.Caused by Poor Seal Design.Mods Will Be Completed During Current Outage & Followed by Retest + (ML20028C839)
- ML20028C840 + (ML20028C840)
- ML20028C842 + (ML20028C842)
- ML20028C844 + (ML20028C844)
- ML20028C845 + (ML20028C845)
- ML20028C846 + (ML20028C846)
- ML20028C847 + (ML20028C847)
- ML20028C848 + (ML20028C848)
- ML20028C849 + (ML20028C849)
- ML20028C850 + (ML20028C850)
- 05000277/LER-1982-040-03, /03L-0:on 821205,flow to Drywell Air Sampling Sys Discovered Less than 5 Scfh,Rendering Sys Inoperable. Caused by Mispositioned Control Room Sample Selector Switch.Switch Repositioned + (ML20028C851)
- ML20028C852 + (ML20028C852)
- ML20028C853 + (ML20028C853)
- ML20028C854 + (ML20028C854)
- ML20028C855 + (ML20028C855)
- ML20028C857 + (ML20028C857)
- 05000245/LER-1982-020, Forwards Updated LER 82-020/01X-2.Detailed Event Analysis Encl + (ML20028C858)
- ML20028C860 + (ML20028C860)
- ML20028C862 + (ML20028C862)
- ML20028C865 + (ML20028C865)
- 05000245/LER-1982-020-01, During Hydraulic Snubber Functional Test,Four Itt Grinnell Snubbers Failed to Meet Design Acceptance Ranges.Caused by Oil Leakage Through Cracked Reservoir Glass.Snubbers Repaired + (ML20028C866)
- ML20028C867 + (ML20028C867)
- ML20028C869 + (ML20028C869)
- IR 05000275/1982039 + (ML20028C871)
- ML20028C872 + (ML20028C872)
- ML20028C873 + (ML20028C873)
- ML20028C874 + (ML20028C874)
- 05000272/LER-1982-092, Forwards LER 82-092/03L-0.Detailed Event Analysis Encl + (ML20028C877)
- ML20028C878 + (ML20028C878)
- ML20028C880 + (ML20028C880)
- ML20028C881 + (ML20028C881)
- IR 05000271/1982019 + (ML20028C882)
- ML20028C884 + (ML20028C884)
- ML20028C885 + (ML20028C885)
- 05000272/LER-1982-092-03, /03L-0:on 821206,containment Air Particulate Monitor 1R11A Indication Found Failed Low.Caused by Channel Failure Due to Failed Scintillation Detector. Detector Replaced & Channel Tested Satisfactorily + (ML20028C886)
- ML20028C887 + (ML20028C887)
- FVY-82-133, Responds to NRC Re Violations Noted in IE Insp Rept 50-271/82-19.Corrective Actions:Fire Watch Personnel Reinstructed in Responsibilities.Fire Proof Kneeling Pads Constructed for Future Use + (ML20028C888)
- ML20028C889 + (ML20028C889)
- ML20028C892 + (ML20028C892)
- ML20028C894 + (ML20028C894)
- ML20028C895 + (ML20028C895)
- ML20028C896 + (ML20028C896)