- ML20028C187 + (ML20028C187)
- 05000316/LER-1982-102-03, /03L-0:on 821209,during Surveillance Test on Automatic Load Sequence Timing Relays,Two Timers Exceeded Tech Spec Tolerance.Caused by Component Cooling Water Pump 2E Timer out-of-spec.Timers Calibr + (ML20028C188)
- ML20028C190 + (ML20028C190)
- 05000316/LER-1982-103-03, /03L-0:on 821128,30 & 1202,temporary Fire Seal for Fire Barrier Penetration W-9392 Missing & Seal W-9393 Nonfunctional.Caused by Intentional Violation to Perform Mod.Security Surveillance Established + (ML20028C191)
- ML20028C193 + (ML20028C193)
- ML20028C195 + (ML20028C195)
- ML20028C196 + (ML20028C196)
- 05000373/LER-1982-160, Forwards LER 82-160/03L-0 + (ML20028C198)
- ML20028C199 + (ML20028C199)
- 05000237/LER-1982-049, Forwards LER 82-049/03L-0 + (ML20028C201)
- ML20028C202 + (ML20028C202)
- 05000373/LER-1982-168-03, /03L-0:on 821201,steam Leak Discovered on Pressure Sensing Line for RCIC Instruments DPIS 1E31-N0007B & Ps 1E31-N022B&D.Caused by Failure of Compression Fitting on Instrumentation Steam Pressure Line.Leak Repaired + (ML20028C203)
- 05000373/LER-1982-160-03, /03L-0:on 821124,while Running at 450 Mwt,Leak Detected on High Point Vent Line for Discharge Line from Condensate Booster Pump 1B.Cause Undetermined.Line Repaired + (ML20028C205)
- ML20028C206 + (ML20028C206)
- ML20028C208 + (ML20028C208)
- 05000325/LER-1982-145, Forwards LER 82-145/03L-0 + (ML20028C209)
- ML20028C210 + (ML20028C210)
- 05000325/LER-1982-134, Forwards LER 82-134/03L-0 + (ML20028C211)
- ML20028C212 + (ML20028C212)
- 05000325/LER-1982-145-03, /03L-0:on 821129,main Steam Safety Relief Valve (SRV) Position Indication Instrument 1-B21-TR-R614,points 2 & 4 Printed Intermittently on Chart Paper.Srv Sonic Detector Lights Inoperable.Caused by Timing Motor Gear Teeth Wea + (ML20028C213)
- IR 05000346/1982032 + (ML20028C214)
- ML20028C215 + (ML20028C215)
- PNO-II-83-001, on 831224,logging Tool Broken Open to Remove Threaded,Scaled 125-mCi Cs-137 Source.Caused by Prof Logging Svcs Employee Action.Complete Decontamination & Proper Disposal of Contaminated Matl to Be Performed + (ML20028C216)
- 05000325/LER-1982-134-03, /03L-0:on 821201,primary Containment Atmosphere Oxygen analyzer,1-CAC-AT-1263-2,indicated Step Increase in Drywell Oxygen Concentration.Caused by 1262-2 Analyzer Experiencing Instrument Zero Shift.Analyzer Recalibr + (ML20028C217)
- ML20028C218 + (ML20028C218)
- ML20028C219 + (ML20028C219)
- ML20028C220 + (ML20028C220)
- 05000325/LER-1982-121, Forwards LER 82-121/03L-0 + (ML20028C222)
- ML20028C223 + (ML20028C223)
- ML20028C224 + (ML20028C224)
- ML20028C225 + (ML20028C225)
- IR 05000344/1982034 + (ML20028C226)
- 05000237/LER-1982-049-03, /03L-0:on 821128,during Quarterly Valve Timing Surveillance DOS 1600-1,torus Inert & Purge Valve 2-1601-56 Would Not auto-close.Caused by Versa Valve Leaking from Weep Hole Due to Hardening of O-ring Seal.Valve Replaced + (ML20028C227)
- 05000295/LER-1982-046, Forwards LER 82-046/03L-0 + (ML20028C228)
- 05000325/LER-1982-121-03, /03L-0:on 821130,RTGB Control switch,1-VA-CS-2581 for Standby Gas Treatment Sys 1B Was in Standby,Not Preferred Position.Caused by Failed Spring Return Function. Switch Repaired,Cleaned & Restored to Svc + (ML20028C230)
- PNO-V-82-051, on 821229,liquid Radwaste Monitor Found Inoperable.Caused by Flow Director Kerotest Valve Being Installed Backwards.Valve Cutout,Reversed & Reinstalled in Proper Direction + (ML20028C231)
- 05000416/LER-1982-154, Forwards LER 82-154/03L-0 + (ML20028C232)
- ML20028C233 + (ML20028C233)
- AECM-82-644, Rsps:On 821229,unidentified Caller Telephoned Threat Re Bomb in Bathroom of Administration Bldg.No Bomb Found.Call Considered Hoax + (ML20028C234)
- 05000295/LER-1982-046-03, /03L-0:on 821203,while Disassembling Discharge Valve,Crosstie Valve Between Boric Acid Transfer Pumps 1A & 1B Found Leaking.Caused by Valve Normal End of Life.Repairs Completed & Pump 1A Returned to Svc + (ML20028C235)
- ML20028C236 + (ML20028C236)
- ML20028C238 + (ML20028C238)
- ML20028C240 + (ML20028C240)
- ML20028C241 + (ML20028C241)
- 05000416/LER-1982-154-03, /03L-0:on 821204,shutdown Cooling Loop a of RHR Secured for Standby Svc Water Loop a Hydrostatic Test.Caused by Need to Perform Hydrostatic Test.Reactor Water Cleanup Used as Alternate DHR Method + (ML20028C242)
- 05000306/LER-1982-025-03, /03L-0:on 821130,one Steam Flow Channel Differed from Redundant Channels During Power Reduction Due to out- of-calibr Transmitter.Cause Not Known.Transmitter Recalibr & Returned to Svc.Transmitter to Be Replaced If Drift Rec + (ML20028C244)
- IR 05000255/1982025 + (ML20028C245)
- 05000324/LER-1982-133, Forwards LER 82-133/03L-0 + (ML20028C246)
- ML20028C247 + (ML20028C247)
- ML20028C248 + (ML20028C248)
- 05000324/LER-1982-133-03, /03L-0:on 821204 & 05,discovered Inoperable RTGB Position Indication for Control Rods 10-31,38-23 & 18-11. Caused by Defective IC Chip & Transistor on Probe Buffer Board of Rod 18-11 & Defective Reed Switch + (ML20028C250)