- IR 05000397/1983013 + (ML20023C459)
- ML20023C461 + (ML20023C461)
- ML20023C463 + (ML20023C463)
- 05000369/LER-1983-017, Forwards LER 83-017/03L-0 + (ML20023C466)
- ML20023C467 + (ML20023C467)
- 05000369/LER-1983-017-03, /03L-0:on 830405,during Draining of Refueling Cavity RHR (Nd) Pumps Began to Cavitate & Eventually Both Nd Pumps Stopped.Caused by Level Gauge Isolation.Cavity Refilled.Nd Sys Vented.Procedures Revised + (ML20023C469)
- ML20023C470 + (ML20023C470)
- IR 05000361/1983018 + (ML20023C472)
- ML20023C475 + (ML20023C475)
- IR 05000206/1983012 + (ML20023C477)
- 05000311/LER-1983-006, Forwards LER 83-006/04L-0.Detailed Event Analysis Encl + (ML20023C478)
- ML20023C479 + (ML20023C479)
- 05000311/LER-1983-006-04, /04L-0:on 830408,decreased Sensitivity of Channel 2R41C Plant Vent Noble Gas Monitor Rendered Waste Gas Discharge Line Automatic Isolation Feature Inoperable.Caused by Leakage on Monitor Sample Lines & Internal Connections + (ML20023C482)
- ML20023C483 + (ML20023C483)
- ML20023C484 + (ML20023C484)
- ML20023C485 + (ML20023C485)
- 05000373/LER-1983-034, Forwards LER 83-034/03L-0 + (ML20023C486)
- ML20023C487 + (ML20023C487)
- ML20023C488 + (ML20023C488)
- ML20023C490 + (ML20023C490)
- ML20023C491 + (ML20023C491)
- 05000373/LER-1983-034-03, /03L-0:on 830408,during LIS-HP-10,level Indicating Switch 1B21-N100A as-found Setpoint Exceeded Tech Spec Value.Caused by Setpoint Drift.Switch Setpoint Recalibr + (ML20023C493)
- ML20023C496 + (ML20023C496)
- IR 05000397/1983010 + (ML20023C497)
- IR 05000528/1983013 + (ML20023C498)
- 05000373/LER-1983-035, Forwards LER 83-035/03L-0 + (ML20023C499)
- ML20023C500 + (ML20023C500)
- ML20023C501 + (ML20023C501)
- RBG-14-984, Interim Deficiency Rept DR-109 Re Velan 3/4-inch,600 Lb, socket-welded Globe Valves W/Counterbores Not Concentric to Valve Ctr.Initially Reported on 830408.Nonconcentric Counterbores May Cause Weld Problems.Next Rept by 830613 + (ML20023C503)
- ML20023C505 + (ML20023C505)
- 05000373/LER-1983-035-03, /03L-0:on 830406,offgas Hydrogen Analyzer 1A Not Maintaining Proper Vacuum & Analyzer 1B Not Wired Properly. Caused by Dirty Flame Arrestor on Analyzer A.Flame Arrestor Cleaned.Analyzer B Rewired + (ML20023C506)
- 05000366/LER-1983-017, Forwards LER 83-017/03L-0 + (ML20023C507)
- ML20023C508 + (ML20023C508)
- ML20023C509 + (ML20023C509)
- ML20023C510 + (ML20023C510)
- ML20023C511 + (ML20023C511)
- ML20023C513 + (ML20023C513)
- ML20023C514 + (ML20023C514)
- 05000366/LER-1983-017-03, /03L-0:on 830406,during HNP-2-3322,w/unit in Cold Shutdown,Hpci Pump Discharge Valve 2E41-F006 Failed to Open. Caused by Loose Wire on Terminal Block Inside Valve Operator.Wire Tightened.Valve Cycled + (ML20023C515)
- ML20023C516 + (ML20023C516)
- ML20023C517 + (ML20023C517)
- ML20023C518 + (ML20023C518)
- ML20023C519 + (ML20023C519)
- 05000302/LER-1983-020, Forwards LER 83-020/03L-0 + (ML20023C521)
- ML20023C522 + (ML20023C522)
- ML20023C523 + (ML20023C523)
- ML20023C524 + (ML20023C524)
- 05000302/LER-1983-020-03, /03L-0:on 830409,discovered That Surveillance Interval for Fire Detection Instrumentation in Emergency Diesel Generator & Control Rooms Exceeded by 6 Months.Caused by Procedural Inadequacy.Procedure SP-411 Will Be Revised + (ML20023C525)
- IR 05000373/1983011 + (ML20023C526)
- ML20023C527 + (ML20023C527)
- 05000338/LER-1983-021, Forwards LER 83-021/03L-0 + (ML20023C530)