ML20023C500

From kanterella
Jump to navigation Jump to search
Forwards LER 83-035/03L-0
Date released: 02/06/2020 Download: ML20023C500


LER 83-035/03L-0:on 830406,offgas Hydrogen Analyzer 1A Not Maintaining Proper Vacuum & Analyzer 1B Not Wired Properly. Caused by Dirty Flame Arrestor on Analyzer A.Flame Arrestor Cleaned.Analyzer B Rewired
ML20023C506
Person / Time
Site: LaSalle Constellation icon.png
Issue date: 05/04/1983
From: Houston R
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20023C506 (2)
Forwards LER 83-035/03L-0
ML20023C499
Person / Time
Site: LaSalle Constellation icon.png
Issue date: 05/04/1983
From: Diederich G
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20023C499 (1)