- 05000344/LER-1981-014-03, /03L-0:on 810728,during Routine Operator Surveillance at 80% Power,Main Containment Isolation Valve for Demineralized Water Washdown Found in Open Position. Caused by Personnel Negligence.Valve Closed & Locked + (ML20010F549)
- ML20010F550 + (ML20010F550)
- ML20010F551 + (ML20010F551)
- ML20010F552 + (ML20010F552)
- 05000344/LER-1981-017, Forwards LER 81-017/03L-0.Detailed Event Analysis Encl + (ML20010F553)
- 05000315/LER-1981-033-01, /01T-0:on 810814,inadequacy Found in Installation of safety-related Cabinets During Insp Per Generic Ltr 81-14.Caused by Design Deficiency in Anchorage of Cabinets. Temporary Bracing Completed Pending Permanent Mod + (ML20010F555)
- PNO-V-81-043A, insp Conducted During Wk of 810727 Revealed Significant Voids in Concrete Placement.Licensee Will Submit 10CFR50.55(e) Rept & Will Make Repairs in Accordance W/ Procedures Developed Specifically for Such Condition + (ML20010F556)
- 05000344/LER-1981-017-03, /03L-0:on 810731,after Increasing Level in C SI Accumulator by 11%,boron Concentration Not Verified within 6-h,per Tech Spec.Caused by Personnel Error.Sample Taken Upon Discovery.Importance of Sample Stressed to Personnel + (ML20010F557)
- 05000301/LER-1981-006, Forwards LER 81-006/03L-0 + (ML20010F558)
- ML20010F559 + (ML20010F559)
- ML20010F560 + (ML20010F560)
- 05000301/LER-1981-006-03, /03L-0:on 810803,during Routine Calibr Check of Pressurizer Level Instrumentation,One Channel Found Outside Tech Spec Range.Caused by Zero Drift of Level Transmitter Calibr.Instrument Adjusted.New Calibr Procedure Formalized + (ML20010F561)
- ML20010F562 + (ML20010F562)
- B10276, Forwards Safety Assessment for SEP Topic III-4.A Re Tornado Missiles.Facility Meets Criteria Except For:Atmospheric Dump Valve,Auxiliary Feedwater Pumps,Primary Water Storage Tank & Svc Water Pump Motors + (ML20010F563)
- ML20010F564 + (ML20010F564)
- ML20010F569 + (ML20010F569)
- ML20010F570 + (ML20010F570)
- ML20010F572 + (ML20010F572)
- FVY-81-131, Forwards Info Requested in NRC Safety Evaluation Re Environ Qualification of safety-related Electrical Equipment + (ML20010F573)
- ML20010F577 + (ML20010F577)
- ML20010F579 + (ML20010F579)
- ML20010F581 + (ML20010F581)
- ML20010F582 + (ML20010F582)
- ML20010F583 + (ML20010F583)
- ML20010F584 + (ML20010F584)
- ML20010F585 + (ML20010F585)
- ML20010F586 + (ML20010F586)
- ML20010F587 + (ML20010F587)
- ML20010F588 + (ML20010F588)
- ML20010F590 + (ML20010F590)
- AECM-81-299, Submits Corrections to 810722 Ie,Div of Emergency Preparedness,Implementation Appraisal Schedule & Proposed Exercise Schedule. Emergency Plan Exercise Listed for 811118 Actually Scheduled for 811103-05 + (ML20010F591)
- 05000315/LER-1981-026, Forwards LER 81-026/99T-0 + (ML20010F592)
- ML20010F593 + (ML20010F593)
- A01798, Forwards Respose to NRC 810617 Request for Addl Info Re SEP Topics III-6, Seismic Design Considerations, III-7.B, Design Codes,Design Criteria,Load Combinations... & Topic III-2, Wind & Tornado Loadings. W/O Encl + (ML20010F594)
- ML20010F595 + (ML20010F595)
- 05000315/LER-1981-026-99, /99T-0:on 810729,missing Bearing Plate Caused Loud Thump to Be Heard by Personnel.Caused by sheared-off Studs Allowing Plate to Fall from Installed Location.Bearing Plate Reinstalled & Readjusted + (ML20010F596)
- ML20010F597 + (ML20010F597)
- ML20010F598 + (ML20010F598)
- ML20010F599 + (ML20010F599)
- ML20010F600 + (ML20010F600)
- ML20010F601 + (ML20010F601)
- ML20010F602 + (ML20010F602)
- ML20010F603 + (ML20010F603)
- ML20010F604 + (ML20010F604)
- ML20010F605 + (ML20010F605)
- ML20010F606 + (ML20010F606)
- ML20010F607 + (ML20010F607)
- ML20010F608 + (ML20010F608)
- ML20010F609 + (ML20010F609)
- ML20010F610 + (ML20010F610)
- ML20010F611 + (ML20010F611)