ML20010F559

From kanterella
Jump to navigation Jump to search
Forwards LER 81-006/03L-0
Date released: 01/24/2020 Download: ML20010F559


LER 81-006/03L-0:on 810803,during Routine Calibr Check of Pressurizer Level Instrumentation,One Channel Found Outside Tech Spec Range.Caused by Zero Drift of Level Transmitter Calibr.Instrument Adjusted.New Calibr Procedure Formalized
ML20010F561
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 08/20/1981
From: Fay C
WISCONSIN ELECTRIC POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20010F561 (2)
Forwards LER 81-006/03L-0
ML20010F558
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 08/20/1981
From: Fay C
WISCONSIN ELECTRIC POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20010F558 (1)