Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20009A187 + (ML20009A187)
- ML20009A188 + (ML20009A188)
- ML20009A189 + (ML20009A189)
- ML20009A190 + (ML20009A190)
- ML20009A191 + (ML20009A191)
- ML20009A192 + (ML20009A192)
- ML20009A193 + (ML20009A193)
- ML20009A194 + (ML20009A194)
- ML20009A195 + (ML20009A195)
- ML20009A196 + (ML20009A196)
- ML20009A197 + (ML20009A197)
- ML20009A198 + (ML20009A198)
- ML20009A199 + (ML20009A199)
- ML20009A200 + (ML20009A200)
- ML20009A201 + (ML20009A201)
- ML20009A202 + (ML20009A202)
- ML20009A203 + (ML20009A203)
- ML20009A204 + (ML20009A204)
- ML20009A205 + (ML20009A205)
- FVY-81-101, Discusses Aspects of Placing Inst of Nuclear Power Operations plant-specific Evaluation Repts on Docket,Per Generic Ltr 81-23.Placing Repts on Docket in PDR Will Potentially Reduce Mgt Prerogative Re Implementation + (ML20009A206)
- ML20009A207 + (ML20009A207)
- 05000206/LER-1981-008, Forwards LER 81-008/03X-0.Detailed Event Analysis Also Submitted + (ML20009A208)
- ML20009A210 + (ML20009A210)
- ML20009A211 + (ML20009A211)
- 05000206/LER-1981-008-03, /03X-0:on 810504,insp of Thermal Sleeve & Feedring Assembly on Steam Generator B Found Thermal Sleeve Deformation in Feed Nozzle Area,Radial Indications at Several Feedring Distribution Holes & Other Defects + (ML20009A212)
- 05000312/LER-1981-032, Forwards LER 81-032/03L-0 + (ML20009A216)
- ML20009A218 + (ML20009A218)
- 05000312/LER-1981-032-03, /03L-0:on 810527,snubber W/Nearly Empty Accumulator on Letdown Cooler Discovered During Sp at Cold Shutdown.Caused by Leaking Valve Block Seal.Snubber Removed, Adjusted & Reinstalled & Seal Replaced + (ML20009A220)
- IR 05000482/1981011 + (ML20009A221)
- FVY-81-102, Informs That Lines Containing Nonconforming Matl Will Not Be Replaced,In Response to NUREG-0313 & Generic Ltr 81-03. Program Will Be Developed to Address NRC Inservice Insp & Leak Detection Requirements by Oct 1981 + (ML20009A222)
- ML20009A223 + (ML20009A223)
- IR 05000298/1981009 + (ML20009A224)
- ML20009A225 + (ML20009A225)
- ML20009A226 + (ML20009A226)
- 05000206/LER-1981-009, Forwards LER 81-009/01T-0.Detailed Event Analysis Also Submitted + (ML20009A227)
- ML20009A229 + (ML20009A229)
- 05000206/LER-1981-009-01, /01T-0:on 810609,low Coolant Flow Rate & Butterfly Valve Malfunctions Occurred on Saltwater Discharge Side of Component Cooling Heat Exchanger.Caused by Impeded Valve Movement Due to Gooseneck Barnacle Growth + (ML20009A230)
- 05000206/LER-1981-010, Forwards LER 81-010/03L-0.Detailed Event Analysis Also Submitted + (ML20009A231)
- ML20009A233 + (ML20009A233)
- 05000206/LER-1981-010-03, /03L-0:on 810603 & 05,inadvertent Breach of Primary Containment Occurred When Both Main Containment Personnel Airlock Doors Were Open.Caused by Three Worn Cam Followers & Misaligned Operating Shaft + (ML20009A234)
- ML20009A237 + (ML20009A237)
- ML20009A239 + (ML20009A239)
- ML20009A240 + (ML20009A240)
- 05000206/LER-1980-014-03, /03L-0:on 800414,secondary Side Leakage Test Revealed Nine Tubes to Be Leaking During Refueling Shutdown. Caused by Intergranular Attack at Top of Tubesheet on Hot Leg Side in Central Region of Steam Generators + (ML20009A241)
- ML20009A242 + (ML20009A242)
- IR 05000267/1981010 + (ML20009A243)
- ML20009A244 + (ML20009A244)
- ML20009A245 + (ML20009A245)
- ML20009A247 + (ML20009A247)
- IR 05000498/1981018 + (ML20009A248)
- ML20009A249 + (ML20009A249)