Responds to 810226 Generic Ltr 81-03 Re Implementation of NUREG-0313,Revision 1.All NSSS Supplied Stainless Steel Piping Conforms to Corrosion Resistant Matl Requirements. Tech Specs Re Surveillance & RCPB Leakage Will Be Reviewed
ML20009A198
Person / Time
Site: Perry  FirstEnergy icon.png
Issue date: 07/02/1981
From: Davidson D
CLEVELAND ELECTRIC ILLUMINATING CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
REF-GTECI-A-42, REF-GTECI-PI, RTR-NUREG-0313, RTR-NUREG-313, TASK-A-42, TASK-OR GL-81-03, GL-81-3, NUDOCS 8107090188
Download: ML20009A198 (4)


Text

.'

{ '] p

'i fif. i E

, 53 OL. I _ L.i t 4. O, '

! J r' j

1 '.

u L

1,

)

l[

7 i

i

>L,t*

v<

s 3

P o. BOX 5000 m CLEVELAND. oHlo 44101 e TELEPHONE (216) 622-9800 e ILLUMIN ATING BLOG e

55 PUBLIC SOUARE W

U" Daiwyn R. Davidson VICE PRESiOENT July 2, 1981 t ~ {f /

SYSTE M ENG!NE ERiNG AND CONSTRUCitON

-s f

l f

ik g%,2 b ~ f *.-11

\\~,

P,., Q h ll

  1. go Mr. Darrell G. Eisenhut, Director o.S c

Division of Licensing U. S. Nuc1 car Regulatory Commission Aa j 'rM\\T Washington, D. C.

20555

Dear Mr. Eisenhut:

This letter is in response to your Generic Letter 81-03, dated February 26, 1981, concerning implementation of NUREG-0313, Revision 1, "Techni-cal Report on Material Selection and Processing Guidelines for BWR Cool-ant Pressure Boundary Piping (Generic Task A-42)."

We have reviewed all the ASME Code Class 1, 2, and 3 pressure boundary and engineered safety features systems piping, safe ends and fitting material, including weld metal, at the Perry Nuclear Power Plant to determine if the austenitic stainless steel piping meets the guidelines of NUREG-0313, Rev-ision 1.

All NSSS-supplied stainless steel piping now conforms to the corrosion-resistant material requirements of Section III of the guidelines. Measures have been implemented to reduce the susceptibility to intergranular stress corrosion cracking, including application of corrosion-resistant cladding followed by solution annealing on the recirculation piping, including riser lines, and replacement of recirculation inlet safe end and thermal sleeves with 316L austenitic stainless steel material having a no-crevice design.

Additionally, service sensitive recirculation bypass lines, CRD hydraulic return line and isolation condenser lines have been deleted. The Standby Liquid Control System Piping will be fabricated from Type 316L stainless steel conforming to the material requirements of NUREG-0313, Revision 1.

Since all this piping conforms to the material selection and processing guidelines of NUREG-0313, Revision 1, there is no need for augmented in ser-vice inspection and leak detection methods.

All Reactor Coolant Pressure Boundary (RCPB) and Engineered Safety Features (ESP) systems stainless steci piping, other than the NSSS supplied and the Standby Liquid Control system are fabricated from Type 304 stainless steel. h O !

Individual pipe lengths and fittings have been procured in the solution annealed condition under ASME Specifications SA-312, SA-376, and SA-403.

S Also, the following weld methods are employed for all pipe sizes:

//

8107090188 810702 PDR ADOCK 05000440 A

PDR

f::

Mr. Darrell G. Eisenhut July 2, 1981 a.

Weld heat input is controlled to limit the material heat flux valves to avoid the conditions that cause excessive sensitization.

b.

Weld interpass temperatures are limited to a maximum of 350 F. and the weld weave pattern is limited to a maximum of four times the core wire diameter to con-trol the heat build-up which contributes to excessive sensitization.

c.

Weld procedures also conform to the guidelines of NRC Regulatory Guide 1.44, " Control of the Use of Sensitized Stainless Steel."

In addition, all piping two-inch nominal pipe size or less is field fabri-cated using socket welded fittings which prevent the welded portion of pipe from being exposed to the reactor coolant or other process fluid. This also eliminates the necessity for interior grinding since the interior surface of the pipe is not disturbed. Socket welding can avoid excessive weld-sensiti-zation of the pipe inside surface when proper welding procedures are followed.

Large diameter piping (greater than two inches nominal pipe size) does not utilize socket weld fittings, rather is butt welded. Therefore, it is included in the attached table identifying the piping materials found to be "nonconfor-ming" per the NUREG-0313, Revision 1,Section III criteria. Replacement of these materials would present undue hardship, since Perry Unit 1 and conmon facilities are 76 percent complete, with nearly all the affected piping received and 80 percent installed. Although a smaller percentage of Unit 2 piping has been installed, 80 percent of the large diameter piping has already been received. Our experience has shown lead times for replacement of some piping would exceed one year.

4 Noting the very high degree of protection against stress corrosion cracking provided, moderate design conditions, function, and location of the piping, the fact that the piping is not service sensitive, as well as the hardships j

involved, no augmented in-service inspection or additional leakage detection capability will be implemented.

I I

Technical specifications concerning general surveillance requirements and RCPB leakage detection will be reviewed prior to submittal to incorporate changes, as appropriate, to conform to the guidance of the report.

l If you require any further information, please let us know.

4 l

Very truly yours,

/

/

l D. R. Davidson i

Vice President i

System Engineering and Construction DRD: bas Enclosure cc:.G. Charnoff J. Hughes, Resident Inspector

System Drawing ASME Hormal No.

Description No.

Class Size Mat'l.

Temp.

C-ll Control Rod Drive Hydraulic System Drive water piping at Pen. P204 D-302-871 2

2}"B.W.

304 S.S.

240 between F083 and F122 D-302-872 (Approximately 15 ft.)

E-12 Residual Heat Removal System Test return lines to suppression pool D-302-642 2

10" 304 S.S.

358 downstream of reducing orifice D003 Flanged A & B (Approximately 20 ft.)

(weld neck)

Test return line to suppression pool D-302-642 2

18" 304 S.S.

358 downstream of reducing orifice D008 Flanged (Approximately 20 ft.)

(weld neck)

Safety relief valve discharge to D-302-642 2

6" 304 S.S.

2120 suppression pool downstream of reducing Flanged orifice D-006 A & B (Approximately 20 ft.)

(weld neck)

E-22 High Pressure Core Spray Test return line to suppression pool D-302-701 2

12" 304 S.S.

120 downstreta of reducing orifice D005 Flanged (Approximately 20 ft.)

(weld neck)

G-41 Fuel Pool Cooling and Cleanup Piping to surge tank at Pen. P301 D-302-651 2

10" B.W.

304 S.S.

180 between MCV-P140 and MCV-F145 (Approximately 10 ft.)

Piping from filter /demineralizer system D-302-651 2

8" B.W.

304 S.S.

180 at Pen. P203 between MCV-F100 and check value F522 (Approximately 10 ft.)

w System Drawing ASME Normal No.

Description No.

Class Size Mat'l.

Temp.

G-41 Fuel Pool Cooling and Cleanup Balance of piping including connections D-302-651 3

16" B.W.

304 S.S.

212 to other systems D-302-654 12" B.W.

304 S.S.

212 D-302-655 10" B.W.

212 8" B.W.

212 6" B.W.

2120 4" B.W.

212 3" B.W.

212 G-43 Suppression Pool Makeup Suppression pool makeup lines between D-302-686 2

24" B.W.

304 S.S.

50 seperator storage well and MCV-Who A & B G-50 Liquid Radwaste Spent resin tank outlets D-302-735 3

6" B.W.

304 S.S.

Ambient 4" B.W.

RWCU filter /demineralizer backwash receiving tank outlets D-302-737 3

4" B.W.

304 S.S.

Ambient RWCU filter /demineralizer backwash D-302-737 3

4" B.W.

304 S.S.

Ambient settling tank outlets P-ll Condensate Transfer and Storage Condensate Storage Tank outlet line D-302-102 2

18" B.W.

304 S.S.

135 downstream of F518 (Approximately 230 ft.

yard piping and 75 ft. indoors)

Branch Connection from Condensate Storage D-302-102 2

16" B.W.

304 S.S.

135 Tank outlet line to HPCS System (Approx. 100 ft.)

Branch Connection from Condensate Storage D-302-101-2 6" B.W.

304 S.S.

135 Tank outlet line to RCIC System at E51-F010 (Approximately 12 ft.)

.