- ML20003A952 + (ML20003A952)
- 05000327/LER-1981-006, Forwards LER 81-006/03L-0 + (ML20003A953)
- ML20003A954 + (ML20003A954)
- ML20003A955 + (ML20003A955)
- ML20003A956 + (ML20003A956)
- ML20003A958 + (ML20003A958)
- ML20003A959 + (ML20003A959)
- ML20003A961 + (ML20003A961)
- 05000333/LER-1981-001, Forwards LER 81-001/01T-0 + (ML20003A962)
- ML20003A963 + (ML20003A963)
- ML20003A964 + (ML20003A964)
- ML20003A965 + (ML20003A965)
- 05000333/LER-1981-003, Forwards LER 81-003/03L-0 + (ML20003A967)
- ML20003A968 + (ML20003A968)
- ML20003A969 + (ML20003A969)
- 05000302/LER-1981-002, Forwards LER 81-002/03L-0 + (ML20003A970)
- ML20003A971 + (ML20003A971)
- ML20003A972 + (ML20003A972)
- ML20003A973 + (ML20003A973)
- 05000333/LER-1981-002-03, /03L-0:on 810106,condensate Storage Tank Level Switches 23-LS-74B & 75B Did Not Operate as Required.Caused by Incorrect Setpoint Due to Moisture.Switches Cleaned, Lubricated & Recalibr + (ML20003A975)
- ML20003A976 + (ML20003A976)
- 05000302/LER-1981-002-03, /03L-0:on 810109,containment Isolation Valve CAV-1 Failed to Close After Sampling Pressurizer Steam Space. Caused by Failed Contacts in Torque Switch of Valve Operator.Switch Replaced & Operability Restored + (ML20003A977)
- ML20003A978 + (ML20003A978)
- 05000344/LER-1980-029-03, /03L-0:on 801231,found That Control Valves Connecting Refueling Water Storage Tank & Spent Fuel Purification Sys Had Deficiency Which Could Prevent Valves Shutting.Caused by Const/Installation Errors + (ML20003A979)
- ML20003A980 + (ML20003A980)
- ML20003A983 + (ML20003A983)
- 05000344/LER-1980-028-03, /03L-0:on 801231,minor Fire in 480 Vac Engineered Safety Feature Motor Control Ctr B22 Rendered Some Containment Isolation Valves,Spray Valves & Air Coolers Inoperable.Caused by Repeated Cycling of Pump Onto Bus + (ML20003A984)
- 05000346/LER-1981-002, Forwards LER 81-002/03L-0 + (ML20003A986)
- ML20003A987 + (ML20003A987)
- ML20003A988 + (ML20003A988)
- 05000313/LER-1980-007-99, Vendor Notified of Discrepancy Between Decay Heat Pump Specs & Parts Supplied. Potential Failure Feared.Tests & Performance History Indicate No Reliability Problems + (ML20003A989)
- 05000346/LER-1981-002-03, /03L-0:on 810102,reactor Coolant Pump 1-2 Was Shutdown Due to High Seal Return Temp & Deteriorating Seal Staging & on 810106,pump 2-1 Was Shutdown for Deteriorating Seal Staging.Caused by Seal Degradation.Seals Replaced + (ML20003A990)
- ML20003A991 + (ML20003A991)
- ML20003A992 + (ML20003A992)
- ML20003A994 + (ML20003A994)
- 05000327/LER-1981-004-03, /03L-0:on 810112,RWST Instrument Channel L-63-54 Failed.Caused by Sense Lines Freezing Due to Insufficient Insulation Around Lines & on Sides of Cabinet Housing Level Transmitter.Heaters in Use Until Insulation Can Be Added + (ML20003A995)
- ML20003A996 + (ML20003A996)
- ML20003A997 + (ML20003A997)
- 05000327/LER-1981-006-03, /03L-0:on 810114,stroke Test Not Performed Following 800929 Repair of Leaking Valve 1-FCV-63-38.Caused by Inadequate Procedure.Procedure Being Revised + (ML20003A998)
- ML20003A999 + (ML20003A999)
- ML20003B001 + (ML20003B001)
- ML20003B003 + (ML20003B003)
- ML20003B004 + (ML20003B004)
- ML20003B005 + (ML20003B005)
- 05000333/LER-1981-001-01, /01T-0:on 810121,problems Re IE Bulletin 80-25 Found in safety-relief Valve Solenoids.Probably Caused by Solenoid Valve Vendor Inadequacy.Eleven Solenoid Pairs Disassembled,Inspected & Cleaned + (ML20003B006)
- ML20003B007 + (ML20003B007)
- 05000333/LER-1981-003-03, /03L-0:on 810106,containment Isolation Valve 16-1-AOV-102A Would Not Close.Caused by Natural End of Life. Valve Will Be Replaced + (ML20003B008)
- ML20003B009 + (ML20003B009)
- ML20003B010 + (ML20003B010)
- ML20003B011 + (ML20003B011)
- ML20003B012 + (ML20003B012)