ML20003A991

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 80-24 Prevention of Damage Due to Water Leakage Inside Containment. Facility Employs Closed Primary Component Cooling Water Sys.Repts Leakage on 761111
ML20003A991
Person / Time
Site: Millstone Dominion icon.png
Issue date: 01/05/1981
From: Counsil W
NORTHEAST NUCLEAR ENERGY CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
A01395, IEB-80-24, NUDOCS 8102100160
Download: ML20003A991 (2)


Text

'.

NORTHEAST UTIEJTIES vm conecicunon mesonta cx"*a' P.o. box 270 3

g"C""C""C4*'C "*"'

HARTFORD CONNECTICUT 06101 UEAsv$N

'^

(

g j

cow-w greTHF Alf NUCLI AA (8(GGV COGSPANT January 5, 1981 Docket No. 50-336 A01395 y P (-

O i

[ I' j', gL' f

g Mr. Boyce H. Grier, Director 7

[

Region 1 9;

JM n 01981 *- -C Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission sowumm 631 Park Avenue M

King of Prussia, PA 19406 g

Reference:

(1) IE Bulletin No. 80-24, " Prevention of Damage Due to Water Leakage Inside Containment (October 17, 1980 Indian Point 2 Event)"

Gentlemen:

Millstone Nuclear Power Station, Unit No. 2 i

IE Bulletin No. 80-24 In Reference (1), the NRC staff requested information concerning design l

and performance of cooling water systems present within the containment.

Actions were required pertaining to both open and closed cooling water systems.

Millstone 2 does not utilize any open cooling water systems within the

~

containment and consequently action items 1 and 2 of subj ect IE Bulletin are not applicable.

Action item 3 requests a summary of experience with closed ecoling water systems. Millstone 2 employs a closed primary component cooling wtaer system (Reactor building Closed Cooling Water - RBCCW).

The only leakage i

within the containment from this system occurred on November 11, 1976.

i A pressure surge caused by starting the RBCCW pumps lifted a relief l

valve on a Control Element Drive Mechanism Cooler, resulting in a rapid increase in containment sump level concurrent with decreasing level in the RBCCW surge tank. A containment entry was made and the relief valve gagged. The relief valve was subsequently repaired at the next plant outage.

i l

8102100 Jo 1

This is the only incident of leakage from the closed cooling water system within the containment. The leak was immediately recognized from containment sump level indication and closed cooling water surge tank level indication.

It is estimated that 12 manhours were expended in the conduct of the review and preparation of this report.

We trust you find this information responsive to the reference (1) request.

Very truly yours, NORTHEAST NUCLEAR ENERGY COMPANY

~

/

i

)h81 W.'G. Counsil

~

Senior Vice President e