e

.~

B ALTIMORE G AS AND ELECTRIC COMPANY P.O. B O X 147 5 B ALTI M CfR E. M A R Y L A N D 2120 3 d)

A (g nEl[jf[g i

Ammum E. LuMOVAR,dm.

=-

[

'I Cb!)SSy % g December 31, 198'o Dd%^^*st M eM g

U.S. Nuclear Regulatory Comission Docke Region I 18 631 Park Avenue King of Prussia, PA 19406 ATTENTION: Mr. B. H. Grier, Director Gentlemen:

This refers to your IE Bulletin 80-24 entitled, " Prevention of damage Due to Water Leakage Inside Containment", dated November 21, 1980.

Within the definitions provided by this bulletin, the Calvert Cliffs Units do not use "open" auxiliary cooling water systems for components within the containments. The Component Cooling Water Systems and Service Water Systems are closed systems in that they utilize a fixed volume and secondary boundary exists to prevent loss of containment integrity as a result of a system leak inside the containment. These systems are described in Chapter 9 of the Final Safety Analysis Report.

Enclosure (1) to this letter provides a maintenance history involving leaks experienced on the systems of interest.

Should you have further questions regarding this matter, we would be pleased to discuss them with you.

Very truly yours, l

(

,j A. E. Lundvall, Jr.

Vice President-Supply AEL/ RED /gla l

810230g\\x_.

Mr. 3oyce H. Grier, Director Decemb r 31, 1980 STATE OF MARYLAND:

TO WIT:

I CITY OF BALTIMORE:

C. H. Poindexter being duly sworn states that he !s Vice President of the Baltimore Gas and Electric Company, a corporation of the State of Maryland; that he provides the foregoing information for the purposes therein set forth; that the statements made are true and correct to the best of his knowledge, information, and belief; and that he was authorized to provide the information on behalf of said Corporation.

WITNESS my hand and Notarial Seal.

6tt 1l. au_

Notary Public O

My Comission Expires:

N.bb 01

/,/kf1 Copy to:

J. A. Biddison, Esquir G. F. Trowbridge, Esquire Director, Nuclear Regulatory Comission Office of Inspection & Enforcement Washington, DC 20555 i

~

ENCLOSURE (1)

HISTORY OF LEAKS ON COMPONENT COOLING AND SERVICE WATER SYSTEMS INSIDE CONTAINMENT i

Unit 1 DATE COMPONENT ESTIMATED LEAK RATE 10/25/77

  1. 11A RCP Cooler

< 0.1 GPM Unit 2 DATE COMPONENT ESTIMATED LEAK RATE 07/16/78

  1. 21B RCP Cooler

<0.1 GPM i-s_..

+

e-

-