- ML20002B934 + (ML20002B934)
- 05000298/LER-1980-043-03, /03L-0:on 801021,motor Operated Valve SW-MO-89B Failed to Open.Caused by Broken Wire Connected to Ohmite 1000-ohm Variable Resistor Inside Valve Operator.Broken Lead Resoldered & Circuit Checked + (ML20002B935)
- 05000298/LER-1980-044, Forwards LER 80-044/01T-0 + (ML20002B937)
- ML20002B938 + (ML20002B938)
- 05000298/LER-1980-044-01, /01T-0:on 801115,reactor Scram Occurred & Normal Cooldown Rate Exceeded.Caused by Failed Card (Westinghouse- Hagan 398522) in Computer Controlled Turbine Control Sys Forcing Main Steam Bypass Valves to Remain Open + (ML20002B939)
- 05000298/LER-1980-039, Forwards LER 80-039/03L-0 + (ML20002B940)
- ML20002B941 + (ML20002B941)
- 05000298/LER-1980-039-03, /03L-0:on 801023,snubber RH-S-29 Discovered Inoperable.Caused by Work in Area Damaging Snubber.Snubber Repaired & Protective Shield Installed + (ML20002B942)
- 05000324/LER-1980-098, Forwards LER 80-098/03L-0 + (ML20002B945)
- 05000324/LER-1980-105, Forwards LER 80-105/03L-0 + (ML20002B948)
- ML20002B950 + (ML20002B950)
- 05000324/LER-1980-105-03, /03L-0:on 801202,TIP Machine a Found W/O TIP Indication Which Prevented Closing of a TIP Ball Valve. Caused by Bent Tube Guide Chafing & Extending Probe Cable Until Breakage Occurred + (ML20002B951)
- ML20002B952 + (ML20002B952)
- W3P80-0440, Responds to DG Eisenhut Re Environ Qualification of safety-related Equipment.Listing of Identified Class IE Equipment for Which Qualification Testing Has Not Been Completed Encl + (ML20002B953)
- ML20002B955 + (ML20002B955)
- ML20002B956 + (ML20002B956)
- ML20002B958 + (ML20002B958)
- ML20002B959 + (ML20002B959)
- ML20002B960 + (ML20002B960)
- ML20002B961 + (ML20002B961)
- ML20002B962 + (ML20002B962)
- ML20002B963 + (ML20002B963)
- ML20002B964 + (ML20002B964)
- ML20002B965 + (ML20002B965)
- AECM-80-306, Reiterates 800926 Request That Requirements Re Sediment Basins Be Deleted from Environ Protection Plan.Sediment Basins Adequately Regulated by NPDES Permit MS0029521 + (ML20002B966)
- ML20002B971 + (ML20002B971)
- 05000298/LER-1980-046, Forwards LER 80-046/03L-0 + (ML20002B974)
- ML20002B975 + (ML20002B975)
- ML20002B976 + (ML20002B976)
- 05000298/LER-1980-046-03, /03L-0:on 801117,isolation Valve on Discharge Line from Drywell Equipment Sump G, RW-A0-94,would Not Open. Caused by Hard & Worn U-cup Seal in Piston Air Operator. New Piston U-cups Installed & Valve Retested + (ML20002B977)
- ML20002B979 + (ML20002B979)
- ML20002B983 + (ML20002B983)
- ML20002B984 + (ML20002B984)
- 05000298/LER-1980-045, Forwards LER 80-045/03L-0 + (ML20002B985)
- ML20002B986 + (ML20002B986)
- 05000324/LER-1980-108, Forwards LER 80-108/03L-0 + (ML20002B987)
- ML20002B988 + (ML20002B988)
- 05000298/LER-1980-045-03, /03L-0:on 801102,hydraulic Shock Suppressor RH-S-43 Found Inoperable Per Radiological Tech Spec.Caused by Suppressor Installed W/Reservoir Connecting Pipe at Wrong End of Reservoir.Suppressor Installed Properly + (ML20002B989)
- 05000324/LER-1980-108-03, /03L-0:on 801202,drywell Equipment Drain Leakage Integrator Indicating Five Gpm W/No Pumps Running.Caused by Drywell Equipment Drain Square Root Converter Being Out of Calibr.Converter Recalibr + (ML20002B990)
- ML20002B991 + (ML20002B991)
- ML20002B992 + (ML20002B992)
- ML20002B993 + (ML20002B993)
- ML20002B995 + (ML20002B995)
- ML20002B997 + (ML20002B997)
- ML20002B998 + (ML20002B998)
- ML20002C000 + (ML20002C000)
- ML20002C003 + (ML20002C003)
- ML20002C004 + (ML20002C004)
- ML20002C007 + (ML20002C007)
- ML20002C008 + (ML20002C008)