Interim Deficiency Rept,Originally Reported on 800606,re Industrial Mechanics,Inc Anchor Bolts & Nuts Having Pitch Diameters Which Do Not Conform W/Tolerance Limitations in Asa/Ansi B1.1-1960.Further Rept Will Be Submitted 801231
ML20002B956
Person / Time
Site: Wolf Creek 
Issue date: 10/29/1980
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Seidle W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, KMLNRC-033, KMLNRC-33, NUDOCS 8101070420
Download: ML20002B956 (2)


Text

~

,9 c,

KANSAS GAS AND ELECTRIC COMPANY M E LE C'mc CON *ANY

c s -j.

es-..

...., m s_

a..

October 29, 1980 Mr. W.C. Seidle, Chief Reactor Construction and Engineering Support Branch U.S. Nuclear Regulator / Comission Region IV 611 Ryan Plaza Drive - Suite 1000 Arlington, Texas 76012 KMIllRC-0 3 3 Re:

NRC Docket No. 50-482 Subj: Interim Report Potential 50.55(e)

Industrial Mechanics, Inc. - Nuts and Bolts

Dear Mr. Seidle :

On June 6, 1980, Messrs.

E.W.

Creel and M.E. Clark reported to Messrs.

W. Crossman and W.

Hubecek of NRC Region IV that some 2-3/4" anchor bolts and nuts supplied to the Wolf Creek Site by Industrial Mechanics, Inc. have minimum and maximum pitch diameters which do not conform to the tolerance limitations specified in ASA/ ANSI Bl.1-1960.

Since June 27 the thread size of all bolts and nuts shipped to Wolf Creek has been checked at the factory to verify that the thread size is within tolerance.

Also, bolts in stock at Wolf Creek which will be needed during the next month have been checked.

Bolts / nuts found to be out of tolerance have been segregated. The Industrial Mechanics, Inc. bolts / nuts in stock which have not been checked have been placed on hold.

Since June an investigation has been carried out to determine the extent of the problem.

It has been found that sizes other than 2-3/4" do not meet the tolerance valuns of the ASA/ ANSI Bl.1 specification.

The gathering of data as requested by the A/E (Bechtel) is nearly complete and analysis has started.

Analysis of several specific applications have been completed and in these cases the bolts / nuts were found to be acceptable for use.

l Bechtel expects to complete analysis of the data, including safety signif-d 8101070 hO 201 N. Market - Wichita. Kansas - Mad Address. PC. Box 208 : Wrchita. Kansas 67201 - Teieonone: Area Coce (3161 261-6451

Mr. W.C. Seidle lotL:1P.C-033 October 29, 1980 icance in Decenber 1980.

A further report regarding this matter will be submitted by December 31, 1980.

Yours very truly, 1