Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19354E121 + (ML19354E121)
- ML19354E123 + (ML19354E123)
- ML19354E124 + (ML19354E124)
- ML19354E125 + (ML19354E125)
- ML19354E126 + (ML19354E126)
- ML19354E127 + (ML19354E127)
- ML19354E129 + (ML19354E129)
- 05000334/LER-1989-017-01, :on 891218,feedwater Isolation Occurred Due to Erroneous Level Transmitter Root Valve Position Indication. Operations Personnel Reset Feedwater Isolation Signal + (ML19354E155)
- ML19354E156 + (ML19354E156)
- ML19354E157 + (ML19354E157)
- ML19354E158 + (ML19354E158)
- ML19354E160 + (ML19354E160)
- ML19354E161 + (ML19354E161)
- 05000456/LER-1987-006-03, :on 870120,4 H Fire Watch Patrol Detained by Radiation Chemistry Personnel Due to Not Signing Latest Radiation Work Permit & on 870131,did Not Start Route.Caused by Personnel Error.Personnel Retrained + (ML19354E162)
- 05000327/LER-1989-036, :on 891221,discovered That Surveillance Test Results Used for Declaring Diesel Generator 1B-B Operable Deficient.Caused by Instruction Not Including 60 Minute Run Time.Event Will Be Reviewed W/Supervisors + (ML19354E163)
- 05000395/LER-1989-021, :on 891218,when Operator Directed to Stop Svc Water Pump C by Positioning Handswitch to auto-after Stop Position,Pump Started,Causing ESF Actuation.Caused by Failed Circuit Board.Board Replaced + (ML19354E164)
- ML19354E165 + (ML19354E165)
- ML19354E167 + (ML19354E167)
- ML19354E168 + (ML19354E168)
- ML19354E169 + (ML19354E169)
- ML19354E170 + (ML19354E170)
- ML19354E172 + (ML19354E172)
- ML19354E173 + (ML19354E173)
- ML19354E174 + (ML19354E174)
- ML19354E175 + (ML19354E175)
- ML19354E176 + (ML19354E176)
- ML19354E187 + (ML19354E187)
- B13428, Responds to 891129 Request for Review of Current & Proposed Lead Factors & Withdrawal Schedule to Determine If Proposed Changes More or Less Conservative Re 10CFR50.92 Significant Hazards Consideration,Per 891020 Tech Spec Rev Request + (ML19354E281)
- ML19354E299 + (ML19354E299)
- ML19354E300 + (ML19354E300)
- ML19354E304 + (ML19354E304)
- ML19354E308 + (ML19354E308)
- ML19354E329 + (ML19354E329)
- 05000368/LER-1989-025-01, :on 891221,two Piping Penetrations Located in Barrier Not Surveilled as Required by Tech Specs.Caused by Personnel Error.Fire Watch Posted When Necessary Per Tech Spec + (ML19354E333)
- 05000364/LER-1989-016, :on 891228,discovered That Required Surveillance for Plant Vent Stack Radioactive Gas Monitor Not Performed.Caused by Personnel Improperly Scheduling Surveillance for Time Later than Due Date + (ML19354E334)
- ML19354E335 + (ML19354E335)
- IR 05000354/1989020 + (ML19354E337)
- 05000311/LER-1989-025-01, :on 891220,ESF Actuation Occurred.Caused by Design/Equipment Concerns.Channel Reset & Declared Operable.Several Sys Design Mods Will Be Made to Eliminate Spurious ESF Actuation Signals + (ML19354E338)
- ML19354E351 + (ML19354E351)
- ML19354E358 + (ML19354E358)
- ML19354E366 + (ML19354E366)
- ML19354E367 + (ML19354E367)
- ML19354E369 + (ML19354E369)
- A08383, Responds to NRC Bulletin 89-003, Potential Loss of Required Shutdown Margin During Refueling Operations. Personnel Trained in Overall Control Procedure for Fuel Movement + (ML19354E380)
- ML19354E387 + (ML19354E387)
- ML19354E389 + (ML19354E389)
- ML19354E390 + (ML19354E390)
- IR 05000369/1989034 + (ML19354E393)
- ML19354E395 + (ML19354E395)
- ML19354E396 + (ML19354E396)
- IR 05000155/1989019 + (ML19354E398)