- ML19340E146 + (ML19340E146)
- ML19340E147 + (ML19340E147)
- PM-80-126, Special Rept 1-sp-80-3:on 801206,during Routine Survey of Waste Oil Drums,Several Areas on Ground Were Found to Be Contaminated.Caused by Storage of Previous Waste Oil Drums. Addl Controls Re Release of Contaminated Oil Under Review + (ML19340E148)
- ML19340E149 + (ML19340E149)
- ML19340E150 + (ML19340E150)
- ML19340E151 + (ML19340E151)
- ML19340E153 + (ML19340E153)
- 05000409/LER-1980-017, Forwards LER 80-017/01T-0 + (ML19340E154)
- ML19340E156 + (ML19340E156)
- ML19340E157 + (ML19340E157)
- ML19340E158 + (ML19340E158)
- 05000338/LER-1980-104, Forwards LER 80-104/99T-0 + (ML19340E160)
- ML19340E161 + (ML19340E161)
- ML19340E162 + (ML19340E162)
- ML19340E164 + (ML19340E164)
- ML19340E165 + (ML19340E165)
- 05000321/LER-1980-122, Forwards LER 80-122/01T-0 + (ML19340E169)
- ML19340E170 + (ML19340E170)
- 05000409/LER-1980-017-01, /01T-0:on 801216,crane Reactor Cavity Purge Check Valve & Bs&B Reactor Vent Header Valve Found Leaking.Caused by Rust & Debris.Valves Replaced + (ML19340E171)
- ML19340E173 + (ML19340E173)
- ML19340E174 + (ML19340E174)
- 05000321/LER-1980-122-01, /01T-0:on 801219,QC Insp of Cable Spreading Room & Control Bldg Sprinkler Hangers Installed in 1978 Revealed Deficiencies Which Jeopardize Seismic Qualification of Sprinkler Sys.Caused by Improper Installation + (ML19340E176)
- ML19340E177 + (ML19340E177)
- 05000338/LER-1980-104-99, /99T-0:on 801223,environ Telemetry Channel 6 for Air Temp Found Out of Tolerance High During Calibr.Caused by Printed Circuit Card Failure in Transmitter Multiplexer.Card Removed & Sent to Manufacturer for Repairs + (ML19340E179)
- ML19340E180 + (ML19340E180)
- ML19340E183 + (ML19340E183)
- ML19340E185 + (ML19340E185)
- ML19340E187 + (ML19340E187)
- 05000237/LER-1980-046-03, /03L-0:on 801202,control Rod Driveline Vol hi-hi Alarm Not Received During Reactor Scram.Caused by Incorrect Cable Length & Routing,Incorrect Transducer Placement & Mounting & Redundant Transducer Signal Interference + (ML19340E188)
- ML19340E191 + (ML19340E191)
- ML19340E192 + (ML19340E192)
- ML19340E194 + (ML19340E194)
- ML19340E195 + (ML19340E195)
- ML19340E196 + (ML19340E196)
- ML19340E197 + (ML19340E197)
- 05000155/LER-1980-040, Forwards LER 80-040/03L-0 + (ML19340E198)
- ML19340E200 + (ML19340E200)
- ML19340E201 + (ML19340E201)
- ML19340E202 + (ML19340E202)
- ML19340E203 + (ML19340E203)
- 05000155/LER-1980-040-03, /03L-0:on 801202,diesel Fire Pump Unit Did Not Produce Full Discharge Pressure Output Until After Starting Time Acceptance Criteria.Cause Undetermined.Engine Jacket Heater Thermostat Control Setting Increased + (ML19340E204)
- ML19340E205 + (ML19340E205)
- ML19340E206 + (ML19340E206)
- 05000321/LER-1980-119, Forwards LER 80-119/03L-0 + (ML19340E207)
- ML19340E208 + (ML19340E208)
- ML19340E209 + (ML19340E209)
- 05000366/LER-1980-121, Forwards LER 80-121/03L-0 + (ML19340E210)
- ML19340E211 + (ML19340E211)
- ML19340E212 + (ML19340E212)
- ML19340E213 + (ML19340E213)
- 05000321/LER-1980-119-03, /03L-0:on 801212,routine Channel Check Showed Fission Product Monitors 1D11-K631,particulate Count & 1D11-K633,noble Gas Count,Were Out of Calibr.Caused by Discriminator Setpoint Drift.Setpoint Adjusted + (ML19340E214)