Forwards LER 80-104/99T-0
Date released: 12/20/2019 Download: ML19340E161


LER 80-104/99T-0:on 801223,environ Telemetry Channel 6 for Air Temp Found Out of Tolerance High During Calibr.Caused by Printed Circuit Card Failure in Transmitter Multiplexer.Card Removed & Sent to Manufacturer for Repairs
ML19340E179
Person / Time
Site: North Anna 
Issue date: 01/02/1981
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19340E179 (2)
Forwards LER 80-104/99T-0
ML19340E160
Person / Time
Site: North Anna 
Issue date: 01/02/1981
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19340E160 (1)