- ML19339C528 + (ML19339C528)
- 05000339/LER-1980-069, Forwards LER 80-069/03L-0 + (ML19339C529)
- ML19339C530 + (ML19339C530)
- ML19339C531 + (ML19339C531)
- ML19339C532 + (ML19339C532)
- ML19339C535 + (ML19339C535)
- 05000339/LER-1980-069-03, /03L-0:during 801012-14,F(Q) Limit Was Exceeded Three Times.Caused by Rod Movement at Beginning of Core Life.Rods Fully Withdrawn While Controlling Power by Borating + (ML19339C536)
- ML19339C538 + (ML19339C538)
- ML19339C539 + (ML19339C539)
- ML19339C540 + (ML19339C540)
- ML19339C541 + (ML19339C541)
- ML19339C542 + (ML19339C542)
- ML19339C543 + (ML19339C543)
- ML19339C545 + (ML19339C545)
- ML19339C546 + (ML19339C546)
- ML19339C547 + (ML19339C547)
- 05000302/LER-1980-046, Forwards LER 80-046/03L-0 + (ML19339C548)
- ML19339C549 + (ML19339C549)
- ML19339C550 + (ML19339C550)
- 05000302/LER-1980-046-03, /03L-0:on 801016,during Normal Operation Emergency Diesel Generator Would Not Start.Cause Not Known.No Problem Found During Troubleshooting.Procedures Revised to Require Leaving Alarm Annunciator as Is Until Failure Determin + (ML19339C551)
- ML19339C552 + (ML19339C552)
- 05000265/LER-1980-027, Forwards LER 80-027/01T-0 + (ML19339C553)
- ML19339C554 + (ML19339C554)
- 05000346/LER-1980-061, Forwards LER 80-061/03L-1 + (ML19339C555)
- ML19339C556 + (ML19339C556)
- ML19339C557 + (ML19339C557)
- ML19339C558 + (ML19339C558)
- ML19339C559 + (ML19339C559)
- 05000346/LER-1980-061-03, /03L-1:on 800812,valve SV5005 Installed 760826 for Temporary Use Was Never Replaced.Caused by Inadequate Implementation of Administrative Control.Valve Secured in Closed Position & Facility Change Request Implemented + (ML19339C560)
- 05000265/LER-1980-027-01, /01T-0:on 801024,while Performing Surveillance Check,Rhr Pump 2C Failed to Start Because Trip Interlock Signal Received from Pump Suction Valve M0-2-1001-7C.Caused by Incorrectly Adjusted Limit Switch.Switch Readjusted + (ML19339C561)
- ML19339C562 + (ML19339C562)
- 05000265/LER-1980-023, Forwards LER 80-023/03L-0 + (ML19339C563)
- ML19339C564 + (ML19339C564)
- ML19339C565 + (ML19339C565)
- ML19339C566 + (ML19339C566)
- 05000327/LER-1980-169, Forwards LER 80-169/03L-0 + (ML19339C567)
- ML19339C568 + (ML19339C568)
- 05000265/LER-1980-023-03, /03L-0:on 801010,during LPCI Motor Operated Valve Operability test,MO-2-1001-29A Valve Initially Failed to Open Fully.Caused by Tightly Seated Valve Disc.Torque Switch Limits Adjusted to Allow More Time to Unseat Valve + (ML19339C569)
- ML19339C573 + (ML19339C573)
- ML19339C576 + (ML19339C576)
- 05000327/LER-1980-169-03, /03L-0:on 801014,output Breaker for Vital Inverter 2-III Tripped Rendering Vital Instrument Power Board Inoperable.Caused by Failure of Clock Card RB5.Clock Card Replaced + (ML19339C577)
- 05000327/LER-1980-165, Forwards LER 80-165/03L-0 + (ML19339C578)