Forwards LER 80-027/01T-0
Date released: 12/19/2019 Download: ML19339C554


LER 80-027/01T-0:on 801024,while Performing Surveillance Check,Rhr Pump 2C Failed to Start Because Trip Interlock Signal Received from Pump Suction Valve M0-2-1001-7C.Caused by Incorrectly Adjusted Limit Switch.Switch Readjusted
ML19339C561
Person / Time
Site: Quad Cities 
Issue date: 11/03/1980
From: Robert Murray
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19339C561 (3)
Forwards LER 80-027/01T-0
ML19339C553
Person / Time
Site: Quad Cities 
Issue date: 11/03/1980
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19339C553 (1)