Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19338F477 + (ML19338F477)
- ML19338F478 + (ML19338F478)
- ML19338F479 + (ML19338F479)
- TXX-3219, Deficiency Rept Re Thread Engagement of Sway Struts. Condition Not Reportable Under 10CFR50.55e,as Reported on 800919 + (ML19338F480)
- 05000259/LER-1980-071-03, /03L-0:on 800919,continuous Air monitor,RM-90-250, Declared Inoperable as Iodine Channel Indicated Downscale. Caused by Condensation in Model AM-331F (Bf) Sample Line. Moisture Removed & Sys Returned to Svc + (ML19338F481)
- ML19338F482 + (ML19338F482)
- 05000320/LER-1980-042, Forwards LER 80-042/03L-0 + (ML19338F483)
- ML19338F485 + (ML19338F485)
- ML19338F486 + (ML19338F486)
- 05000320/LER-1980-042-03, /03L-0:on 800909,during Surveillance Procedures, RCS Flow Instrument Discovered Out of Calibr & Declared Inoperable.Caused by Electronic Component Drift.Instrument Recalibr & Surveillance Completed + (ML19338F487)
- ML19338F488 + (ML19338F488)
- 05000320/LER-1980-041, Forwards LER 80-041/01L-0 + (ML19338F489)
- ML19338F491 + (ML19338F491)
- 05000320/LER-1980-041-01, /01L-0:on 800909,M-9 Incore Thermocouple Exhibited Erratic Behavior.Cause of Failure Not Known.No Action Will Be Taken Re Failure + (ML19338F492)
- ML19338F493 + (ML19338F493)
- ML19338F495 + (ML19338F495)
- 05000293/LER-1980-071, Forwards LER 80-071/03L-0 + (ML19338F496)
- ML19338F497 + (ML19338F497)
- ML19338F498 + (ML19338F498)
- 05000293/LER-1980-071-03, /03L-0:on 800914,A Train of Standby Gas Treatment Sys Declared Inoperable as Main Stack Radiation Levels Had Increased.Caused by Sys Trip.Belts & Bearings Replaced,Fan Lubricated & Returned to Svc + (ML19338F499)
- 05000318/LER-1980-043, Forwards LER 80-043/03L-0 + (ML19338F500)
- ML19338F501 + (ML19338F501)
- 05000318/LER-1980-043-03, /03L-0:on 800914,during Normal operation,22B Safety Injection Tank Level Indication Became Erratic.Cause Not Known.Bench Test Revealed No Malfunction.Level Transmitter Replaced,Recalibr & Returned to Svc + (ML19338F502)
- 05000346/LER-1980-063, Forwards LER 80-063/03L-1 + (ML19338F503)
- ML19338F504 + (ML19338F504)
- ML19338F505 + (ML19338F505)
- ML19338F506 + (ML19338F506)
- 05000346/LER-1980-063-03, /03L-1:on 800823,safety Features Actuation Sys Indication Panel for Damper HV5442 Was Inoperable.Caused by Blown Fuse in Control Circuit.Fuse Replaced & Sys Returned to Svc + (ML19338F507)
- ML19338F508 + (ML19338F508)
- ML19338F510 + (ML19338F510)
- ML19338F511 + (ML19338F511)
- ML19338F513 + (ML19338F513)
- ML19338F515 + (ML19338F515)
- ML19338F516 + (ML19338F516)
- ML19338F517 + (ML19338F517)
- ML19338F518 + (ML19338F518)
- ML19338F519 + (ML19338F519)
- ML19338F520 + (ML19338F520)
- ML19338F521 + (ML19338F521)
- ML19338F522 + (ML19338F522)
- ML19338F523 + (ML19338F523)
- ML19338F524 + (ML19338F524)
- ML19338F525 + (ML19338F525)
- ML19338F526 + (ML19338F526)
- ML19338F528 + (ML19338F528)
- ML19338F529 + (ML19338F529)
- A01165, Provides Info Re Environ Qualification of Electrical Equipment as Partial Fulfillment of License Amend Issued on 800919.Summaries of Methodology Used,Final Radiation Data & Oversize Drawings Encl + (ML19338F531)
- 05000302/LER-1980-039, Forwards LER 80-039/03L-0 + (ML19338F533)
- ML19338F534 + (ML19338F534)
- ML19338F535 + (ML19338F535)
- 05000302/LER-1980-039-03, /03L-0:on 800917,auxiliary Bldg Ventilation Exhaust Fan Failed.Caused by Failure of Two Blades in Fan Assembly.Fan Motor Was Repaired & New Fan Assembly Installed + (ML19338F536)