- ML19338D612 + (ML19338D612)
- ML19338D613 + (ML19338D613)
- ML19338D614 + (ML19338D614)
- ML19338D615 + (ML19338D615)
- ML19338D616 + (ML19338D616)
- ML19338D617 + (ML19338D617)
- 05000339/LER-1980-047-03, /03L-0:on 800819,in Mode 2 at 3% Power,Steam Flow Indications on Loops A,B & C Gave Erroneous Readings.Caused by Design Deficiency in Pressure Sensing Sys of Venturi in Main Steam Line.Engineering Study & Design Mod Carried + (ML19338D619)
- ML19338D620 + (ML19338D620)
- 05000317/LER-1980-048, Forwards LER 80-048/01T-0 + (ML19338D621)
- ML19338D622 + (ML19338D622)
- ML19338D623 + (ML19338D623)
- ML19338D626 + (ML19338D626)
- ML19338D629 + (ML19338D629)
- 05000339/LER-1980-048, Forwards LER 80-048/03L-0 + (ML19338D630)
- ML19338D632 + (ML19338D632)
- ML19338D633 + (ML19338D633)
- ML19338D634 + (ML19338D634)
- 05000317/LER-1980-048-01, /0LT-0:on 800903 During Maint for Control Room 12 Air Conditioner,Unit 11 Compressor Was Not Running & Later Tripped on Overload.Faulty Reset Switch Replaced & Procedures Revised to Require Check of Air Conditioner + (ML19338D637)
- ML19338D639 + (ML19338D639)
- ML19338D641 + (ML19338D641)
- 05000267/LER-1980-046, Forwards LER 80-046/03L-0 + (ML19338D642)
- ML19338D643 + (ML19338D643)
- 05000267/LER-1980-045, Forwards LER 80-045/03L-0 + (ML19338D644)
- ML19338D645 + (ML19338D645)
- 05000339/LER-1980-048-03, /03L-0:on 800828,performing Insp,Technicians Discovered Feed Flow Square Root Comparator Card Out of Calibr.Cause Undetermined.Card Recalibr & Returned to Svc + (ML19338D646)
- ML19338D647 + (ML19338D647)
- ML19338D648 + (ML19338D648)
- 05000267/LER-1980-045-03, /03L-0:on 800816,fitting on Hydraulic Oil Line Ruptured Spraying Oil on Hot Steam Pipes & Producing Heavy Smoke.Fitting Ruptured Due to Normal Usage & Was Replaced. Valve Group Was Isolated to Prevent Addl Oil Loss + (ML19338D649)
- 05000338/LER-1980-075, Forwards LER 80-075/03L-0 + (ML19338D650)
- ML19338D651 + (ML19338D651)
- 05000267/LER-1980-046-03, /03L-0:on 800820,w/plant Operating at Approx 25% Thermal Power,Pcrv Cooling Water Outlet Temp Exceeded 120 F Limit.Caused by Isolation of Cooling Water Due to Operation of Wrong Controllers.Controllers Reset to Proper Positi + (ML19338D652)
- 05000267/LER-1980-044, Forwards LER 80-044/03L-0 + (ML19338D653)
- ML19338D654 + (ML19338D654)
- 05000267/LER-1980-044-03, /03L-0:on 800816,while Operating at 30% Power, Boiler Feed Pump a Was Removed from Svc Due to Unstable Governor Controls.Boiler Feed Pump B Was Out of Svc Also. Caused by Governor Worm Gear Being Loose on Shaft + (ML19338D655)
- 05000338/LER-1980-075-03, /03L-0:on 800904,in Mode 1 at 100% Power,Sample Analysis of SI Accumulator 1B Revealed Excessive Boron Concentration.Caused by Stratification of Stagnant Solution in Accumulator.Concentration Diluted + (ML19338D656)
- ML19338D657 + (ML19338D657)
- A01161, Submits Addl Info Re Seismic re-evaluation Program. Significant Progress Has Been Achieved.Modeling of Structures Is Approx 75% Complete & RCS Is Approx 70% Complete + (ML19338D658)
- 05000338/LER-1980-077, Forwards LER 80-077/03L-0 + (ML19338D659)
- ML19338D660 + (ML19338D660)
- TXX-3193, Forwards Response to NRC 800827 Request for Addl Info Re Environ Review & Amended Environ Review Pages.List of Encls Only Encl.Encls Sent to J Lehr in Separate Package + (ML19338D661)
- ML19338D663 + (ML19338D663)
- ML19338D664 + (ML19338D664)
- AECM-80-220, Final Deficiency Rept Re Design Nomographs Used in Sizing & Selection of Hydramotor Electrohydraulic Actuators Supplied by Itt General Controls.Condition Determined Not Reportable Under 10CFR50.55(e) + (ML19338D665)
- ML19338D666 + (ML19338D666)
- ML19338D667 + (ML19338D667)
- ML19338D668 + (ML19338D668)
- ML19338D669 + (ML19338D669)
- 05000338/LER-1980-077-03, /03L-0:on 800821,performing ECCS Valve Position Verification,Incorrect Valve Alignment Affecting Both Lhsi Pump Min Flow Recirculation Paths Discovered.Cause Relates to Change in Rwat Flow Path Alignment to Reduce Temp + (ML19338D671)
- ML19338D672 + (ML19338D672)
- ML19338D673 + (ML19338D673)
- AECM-80-168, Advises No Other Application Determined for NH90 Series Hydramotor Actuators.No Further Action Planned Per IE Bulletin 80-09 + (ML19338D674)