Third Interim Deficiency Rept Re Rejectable Indications for Welds Which Had Been Previously Accepted.Cause Not Stated. Re-examination & Repair Program for Essential Cooling Water Sys Will Be Performed.Progress Rept by 801215
ML19338D648
Person / Time
Site: South Texas  
Issue date: 09/12/1980
From: Oprea G
HOUSTON LIGHTING & POWER CO.
To:
References
10CFR-050.55E, 10CFR-50.55E, ST-HL-AE-531, NUDOCS 8009230603
Download: ML19338D648 (4)


Text

'1 The Light Company n....,,,,, usiiiiin n,-,

im. s non n. mi.,,.w - oonm> m.mn September 12, 1980

~

ST-HL-AE-531 SFN: V-0530 Mr. Karl Seyfrit Director, Region IV Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76012

Dear Mr. Seyfrit:

South Texas Project Units 1&2 Docket Nos. STN 50-498, STN 50-499 Third Interim Report on the Deficiency Concerning Welds in the Ess'ential Cooling Water System On March 12, 1980, Houston Lighting & Power Company notified your office of a potentially reportable deficiency concerning rejectable indications on the radiographs of the girth welds in the Essential Ccoling Water System (ECW) pipe.

The first interim report submitted April 10, 1930, stated that a review of the radiographs revealed rejectable indications for welds which had been previously accepted, and that a number of films showed radiographic technique /p' ocessing r

problems.

The second report of June 13, 1980,- tied this concern to the Order to Show Cause.

As a result of our Task Force review, HL&P will perform the following Re-examination and repair program for the ECW system:

a.

Accessible Welds (includes buried pipe) 100'.; RT and PT welds made to date and repair as required.

b.

New Welds Utilize WES-4 random RT program for all new welds c.

Inaccessible Welds Use the results of (a) above for enoineering evaluation.

This is a long term effort. A progress report will be submitted by December 15, 1980.

I

$/o 800923OM3' 5

w j

-; Houston Lighting & Iber Company

- September 12, 1980 ST-HL-AE-531

~SFN: :V-0530-Page 2 If there.are any questions, please contact Mr. L.' R. Jacobi at (713) 481-7217.

Very truly yours, O

.l.,i &.

r.

Exec ive \\ 1ce President PLU/ngb o-1

~

l 1

~

pn

_1*~~

~~

C-

t Houmon igeng 1h Compenf Septenber 12,1980 ST-HL-AE-531 SFN: V-0530 Page 3-cc:

D. G. -Barker C. L. ficNeese-H. R. Dean R. L. Waldrop G. B. Painter A. J. Granger R. A. Frazar M. D. Schwarz Baker &Botts)

R. Gordon Gooch.

Bakse & Botts)

J. R. Newman Lowenstein, Newman, Reis, Axelrad & Toll)

Director, Office of Inspection & Enforcement Nuclear Regulatory Comission Washington, D. C. 20555 M. L. Borchelt Executive Vice President 1

Central Power & Light Company 4

P. O. Box 2121 Corpus Christi, Texas 78403 R. L. Range Central Power & Light Company P. O. 2121 Corpus Christi, Texas 78403 R. L. Hancock Director of Electrical Utilities City of Austin P. O. Box 1088 Austin, Texas 78767 T. H. Muehlenbeck

~

City of Austin i

P. O. Box 1088

- Austin, Texas 78767 J. B. Poston Assistant General Manager of Operations City Public Service Board P. O. Box 1771 San Antonio, Texas 78296 j

A. vonRosenberg '

l City Public Service Board 1

P. O. Box 1771 San Antonio, Texas ',78296

- l i

O t

d

-a e-

-wa n.a..-

4 p.-w,e

-n

,4, nu

4 ytmg & Pomer Con 9eny H

-5 SFN:. V-0530 Page 4 Charles Bechoefer. Esquire Chairman, Atomic Safety & Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Dr. James C. Lamb.-III 313 Woodhaven Road Chapel Hill. North Carolina 27514

.Dr. Emmeth A. Luebke 4

Atomic Safety & Licensing Commission U.S. Nuclear Regulatory Commission Washington, D.C.20555 Steven A. Sinkin. Esquire.

'116 Villita Street San Antonio, Texas 78205 i

Citizens for Equitable Utilities c/o Ms. Peggy Buchorn Route 1. Box 432 Brazoria. Texas 77422 Richard W. Lowerre. Esquire Assistant Attorney General for.the State of Texas P. O. Box 12548 Capitol Station Austin, Texas 78711 Henry J. McGurren. Esquire Hearing Attorney

,0ffice of the Executive Legal Director U.S. Nuclear Regulatory Commission Washington, D.C. 20555 1

5 e

J f

w w e e e,

r-..

- - +-

e