ML19338D654

From kanterella
Jump to navigation Jump to search
Forwards LER 80-044/03L-0
Date released: 12/18/2019 Download: ML19338D654


LER 80-044/03L-0:on 800816,while Operating at 30% Power, Boiler Feed Pump a Was Removed from Svc Due to Unstable Governor Controls.Boiler Feed Pump B Was Out of Svc Also. Caused by Governor Worm Gear Being Loose on Shaft
ML19338D655
Person / Time
Site: Fort Saint Vrain 
Issue date: 09/15/1980
From:
PUBLIC SERVICE CO. OF COLORADO
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19338D655 (1)
Forwards LER 80-044/03L-0
ML19338D653
Person / Time
Site: Fort Saint Vrain 
Issue date: 09/15/1980
From: Warembourg D
PUBLIC SERVICE CO. OF COLORADO
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19338D653 (4)