- 05000285/LER-1980-012-03, /03L-0:on 800708,during Performance of ST-RPS-3, F.2,discovered That Trip Unit 3 Setpoints Had Drifted Out of Spec in Nonconservative Direction.Caused by Normal Setpoint Drift.Setpoints Adjusted + (ML19330C349)
- ML19330C350 + (ML19330C350)
- ML19330C351 + (ML19330C351)
- ML19330C352 + (ML19330C352)
- ML19330C353 + (ML19330C353)
- ML19330C355 + (ML19330C355)
- ML19330C356 + (ML19330C356)
- ML19330C357 + (ML19330C357)
- ML19330C358 + (ML19330C358)
- ML19330C359 + (ML19330C359)
- ML19330C360 + (ML19330C360)
- 05000318/LER-1980-008, Forwards LER 80-008/03L-0 + (ML19330C361)
- ML19330C362 + (ML19330C362)
- ML19330C363 + (ML19330C363)
- ML19330C364 + (ML19330C364)
- 05000318/LER-1980-008-03, /03L-0:on 800125,containment Spray Header 22 Was Isolated.Caused by Need to Repair Shutdown Heat Exchanger Inlet Cross Connect Valve.New Packing Installed + (ML19330C366)
- 05000285/LER-1980-013, Forwards LER 80-013/03L-0 + (ML19330C367)
- ML19330C368 + (ML19330C368)
- 05000368/LER-1980-049, Forwards LER 80-049/03L-0 + (ML19330C369)
- ML19330C370 + (ML19330C370)
- ML19330C371 + (ML19330C371)
- 05000285/LER-1980-013-03, /03L-0:on 800707,during Normal Power Operation, Noted That Channel a Dc Sequencer SI-1 Had de-energized on-auto Light.Caused by Sequencer Circuitry Failure Due to Faulty Relay + (ML19330C372)
- ML19330C373 + (ML19330C373)
- ML19330C374 + (ML19330C374)
- 05000368/LER-1980-049-03, /03L-0:on 800707,during Mode 3 Operation,Emergency Feedwater Valve 2CV-1075-1 Failed to Open from Control Room. Caused by Failed Valve Actuator Electric Motor Due to Loose Brush Connection.Motor Replaced & Hydraulic Sys Chec + (ML19330C375)
- ML19330C376 + (ML19330C376)
- 05000313/LER-1980-023, Forwards LER 80-023/03L-0 + (ML19330C377)
- ML19330C378 + (ML19330C378)
- 05000321/LER-1980-087, Forwards LER 80-087/01T-0 + (ML19330C379)
- ML19330C380 + (ML19330C380)
- ML19330C381 + (ML19330C381)
- 05000321/LER-1980-086, Forwards LER 80-086/01T-0 + (ML19330C382)
- ML19330C383 + (ML19330C383)
- 05000313/LER-1980-023-03, /03L-0:on 800709,during Test of Steam Driven Emergency Feed Pump P-7A,main Steam Supply Valve CV-2667 to P-7A Did Not Fully Open on Demand.Caused by Valve Operator Torquing Out Early.Torque Switch Given Small Adjustment + (ML19330C384)
- 05000313/LER-1980-024, Forwards LER 80-024/03L-0 + (ML19330C385)
- ML19330C386 + (ML19330C386)
- 05000321/LER-1980-086-01, /01T-0:on 800724,w/Unit 1 in Cold Shutdown,Support P52-F512-H704 Determined Missing on Instrument Air Sys. Caused by Inadequate Small Bore Piping Design.New Hanger Design Supplied & Support Installed + (ML19330C387)
- ML19330C388 + (ML19330C388)
- ML19330C389 + (ML19330C389)
- ML19330C390 + (ML19330C390)
- 05000313/LER-1980-024-03, /03L-0:on 800706,during Start of Emergency Feedwater Pump Turbine Drive Surveillance,Pump Tripped on Overspeed.Caused by Five of Eight Studs Holding Governor Steam Valve to Turbine Being Broken.All Bolts Replaced + (ML19330C391)
- 05000321/LER-1980-087-01, /01T-0:on 800724 W/Unit Shut Down During IE Bulletin 79-14 Review,Ae Found Anchor Inadequately Supported.Caused by Inadequate Design of Original Support. Design Modified & Anchor Replaced + (ML19330C392)
- ML19330C393 + (ML19330C393)
- 05000155/LER-1980-018, Forwards LER 80-018/03L-0 + (ML19330C394)
- ML19330C398 + (ML19330C398)
- 05000155/LER-1980-018-03, /03L-0:on 800710,during Gravity Check,Cells 35 & 54 of Battery Power Supply for Reactor Depressurizing Sys Channel C Found Below Tech Spec Values.Cause Unknown.Cells Failed to Respond to Charge & Channel Removed from Svc + (ML19330C399)
- ML19330C403 + (ML19330C403)
- 05000318/LER-1979-075, Has Been Cancelled + (ML19330C405)
- 05000317/LER-1979-078-01, Has Been Cancelled + (ML19330C406)