RO-80-11/1P:on 800803,while Investigating Reason for Low Offgas Sample Flow & Radiation Level,Offgas Delay Pipe Sample Line Manual Stop Valve Found Closed.Cause Under Investigation.Results of Further Analysis Forthcoming
ML19330C351
Person / Time
Site: Millstone 
Issue date: 08/04/1980
From: Mroczka E
NORTHEAST NUCLEAR ENERGY CO.
To:
References
MP-1-1578, NUDOCS 8008080274
Download: ML19330C351 (1)


Text

__

UDR1"rIEAST UI1f5HES 3.,553ffC Noo":"an **'

1 pas sw*n L

L

= 0 7,'.'t"l =

Au st 4,1980 1-1578 Mr. Boyce H. Grier Director, Region I Office of Inspection and Enforctsunt U. 5. Nuclear Regulatory Cocnission 631 Park Avenue King of Prussia. Pennsylvania 19406

Reference:

Provisional License DPR-21 Docket No. 50-245

~

Reportable Occurrence R0-80-11/IP

Dear Mr. Grier:

This letter is forwarded to provide prornpt notification of Reportable Occurrence RD-80-11/IP as required by Millstone Unit i Technical Spect ffcations.

On August 3,1980 at 0215 hours0.00249 days <br />0.0597 hours <br />3.554894e-4 weeks <br />8.18075e-5 months <br />, while investigating the. reason for Tow off gas sample fTow and radf ation level, it was discovered that the off gas delay pipe sanple Ifne nanual stop valve was closed.

The delay pipe had been placed in service on 8/2/80 at 2235 hours0.0259 days <br />0.621 hours <br />0.0037 weeks <br />8.504175e-4 months <br /> following minor operating difficulties with the off gas reccachiner syster.

With this valve closed and the off gas delay pipe in service, a high off gas condition wuld not have resulted in closure of the off gas isolation valve.

Upon realtzation of the probTem, the sample If ne stop valve was opened and nomal off gas monitoring was restored.

At the time of the occurrence the plant was operating at steady state full power.

Results of the investigation into the incident and further analysis will be included in the follow-up T4 day report.

Yours truly, MORTHEAST NUCLEAR ENERGY COP'PANY a

c>

S E. J.

tation Superintendent Millstone Nuclear power Station EJM/MJB:11s 4

Director, Office of Kanagerent Infomatf.on and Program Control, cc:

i Washington, D.C.

(2) g l

U. S. Nuclear Regulatory Comission, c/o Docurent Management Branch, Washington, D.C. 20555 9

8008080$'/f.,*

.