- ML19329A976 + (ML19329A976)
- ML19329A978 + (ML19329A978)
- 05000346/LER-1978-068-03, /03L-0:on 780616,vibration on HPI Pump Bearings Exceeded Baseline Tolerance.Caused by Misaligned Pump Due to Loose Mounting Bolts.Bolts Tighened & Pump re-aligned W/Motor.Hpi Pump 1-1 Declared Operable on 780625 + (ML19329A979)
- ML19329A980 + (ML19329A980)
- ML19329A982 + (ML19329A982)
- ML19329A983 + (ML19329A983)
- ML19329A984 + (ML19329A984)
- 05000346/LER-1978-052, Forwards LER 78-052/03L-0 + (ML19329A985)
- ML19329A987 + (ML19329A987)
- ML19329A989 + (ML19329A989)
- ML19329A990 + (ML19329A990)
- ML19329A991 + (ML19329A991)
- 05000346/LER-1978-052-03, /03L-0:on 780515,radiation Monitor Re 2004 Found Inoperable.Inability to Calibr Monitor within Tolerance Limits Caused by Componnet Failure.Untripped Condition Caused by Personnel Error.Replaced Detector + (ML19329A992)
- ML19329A993 + (ML19329A993)
- ML19329A994 + (ML19329A994)
- ML19329A995 + (ML19329A995)
- ML19329A996 + (ML19329A996)
- ML19329A997 + (ML19329A997)
- ML19329A998 + (ML19329A998)
- ML19329A999 + (ML19329A999)
- ML19329B000 + (ML19329B000)
- ML19329B002 + (ML19329B002)
- ML19329B003 + (ML19329B003)
- ML19329B004 + (ML19329B004)
- IR 05000346/1974005 + (ML19329B005)
- ML19329B006 + (ML19329B006)
- ML19329B007 + (ML19329B007)
- ML19329B008 + (ML19329B008)
- ML19329B009 + (ML19329B009)
- IR 05000346/1974010 + (ML19329B011)
- ML19329B012 + (ML19329B012)
- 05000346/LER-1978-070, Forwards LER 78-070/03L-0 + (ML19329B014)
- IR 05000346/1974009 + (ML19329B016)
- ML19329B017 + (ML19329B017)
- 05000346/LER-1978-070-03, /03L-0:on 780619,borated Water Storage Tank Low Level Trip Setpoints Found Out of Tolerance.Caused by Level Trip Module Component Failure.Setpoint on Switch LSL-1525A Drifted.Module Replaced & Tested + (ML19329B020)
- IR 05000346/1974008 + (ML19329B023)
- ML19329B025 + (ML19329B025)
- 05000346/LER-1978-071, Forwards LER 78-071/03L-0 + (ML19329B027)
- ML19329B028 + (ML19329B028)
- IR 05000346/1974006 + (ML19329B029)
- 05000346/LER-1978-071-03, /03L-0:on 780618,containment Spray Pump Failed to Start Automatically on Sequence During Surveillance Test. Caused by Module L-412 Failure & Resulting in Failure of Relays to de-energize.Output Module Replaced + (ML19329B030)
- ML19329B031 + (ML19329B031)
- ML19329B032 + (ML19329B032)
- ML19329B033 + (ML19329B033)
- ML19329B034 + (ML19329B034)
- ML19329B035 + (ML19329B035)
- ML19329B036 + (ML19329B036)
- ML19329B037 + (ML19329B037)
- ML19329B038 + (ML19329B038)
- ML19329B039 + (ML19329B039)
- ML19329B040 + (ML19329B040)