- ML19305D737 + (ML19305D737)
- ML19305D738 + (ML19305D738)
- ML19305D739 + (ML19305D739)
- 05000304/LER-1980-013, Forwards LER 80-013/03L-0 + (ML19305D740)
- ML19305D742 + (ML19305D742)
- ML19305D743 + (ML19305D743)
- ML19305D744 + (ML19305D744)
- 05000366/LER-1980-031, Forwards LER 80-031/01T-0 + (ML19305D745)
- ML19305D746 + (ML19305D746)
- 05000304/LER-1980-013-03, /03L-0:on 800227,during Normal Operation,Maint Personnel Found Steam Generator Pressure Comparator 2PC-536A-B Shifted High by 1.5%.Caused by Defective Unit. Defective Unit Replaced W/Spare Unit + (ML19305D747)
- ML19305D748 + (ML19305D748)
- 05000366/LER-1980-031-01, /01T-0:on 800327,during Performance of 18-month Tests on Station Battery Chargers 2A,2B & 2C,chargers Were Unable to Maintain Load Limits.Caused by Imbalanced Silicon Control Rectifiers & Maladjusted Current Limit Module + (ML19305D749)
- 05000265/LER-1980-008, Forwards LER 80-008/03L-0 + (ML19305D750)
- ML19305D751 + (ML19305D751)
- 05000318/LER-1980-017, Forwards LER 80-017/03L-0 + (ML19305D752)
- ML19305D753 + (ML19305D753)
- ML19305D754 + (ML19305D754)
- ML19305D756 + (ML19305D756)
- ML19305D758 + (ML19305D758)
- 05000318/LER-1980-017-03, /03L-0:on 800316,saltwater Svc Water Heat Exchanger 22 Was Taken Out of Svc.Caused by Need to Repair Tube Leak.Tube Leak Found & Plugged + (ML19305D759)
- ML19305D760 + (ML19305D760)
- ML19305D762 + (ML19305D762)
- ML19305D763 + (ML19305D763)
- ML19305D764 + (ML19305D764)
- ML19305D765 + (ML19305D765)
- ML19305D766 + (ML19305D766)
- ML19305D767 + (ML19305D767)
- ML19305D768 + (ML19305D768)
- ML19305D769 + (ML19305D769)
- IR 05000341/1980002 + (ML19305D770)
- 05000265/LER-1980-008-03, /03L-0:on 800305,while Performing LPCI & Containment Cooling Modes,Two 5-S Delay Timers for Starting 1002D RHR Pump Failed to Actuate Timer Contacts.Caused by Microswitch Arm Being Out of Alignment + (ML19305D771)
- 05000327/LER-1980-022, Forwards LER 80-022/03L-0 + (ML19305D772)
- ML19305D773 + (ML19305D773)
- ML19305D774 + (ML19305D774)
- ML19305D775 + (ML19305D775)
- 05000271/LER-1980-012, Forwards LER 80-012/01T-0 + (ML19305D776)
- ML19305D777 + (ML19305D777)
- ML19305D778 + (ML19305D778)
- 05000271/LER-1980-012-01, /01T-0:on 800328,during Seismic Analysis Required by IE Bulletin 79-14,discovered That Pipe Supports RHR-H-83 & RSW-H-168 May Be Inadequate to Support Seismic Loads. Caused by Deviations from Hanger Design Details + (ML19305D780)
- ML19305D781 + (ML19305D781)
- ML19305D782 + (ML19305D782)
- 05000304/LER-1980-014, Forwards LER 80-014/03L-0 + (ML19305D783)
- ML19305D785 + (ML19305D785)
- 05000259/LER-1980-025, Forwards LER 80-025/03L-0 + (ML19305D786)
- ML19305D787 + (ML19305D787)
- 05000259/LER-1980-024, Forwards LER 80-024/03L-0 + (ML19305D788)
- ML19305D789 + (ML19305D789)
- 05000304/LER-1980-014-03, /03L-0:on 800303,during Normal Operation,Maint Personnel Found Steam Generator Pressure Transmitter 2-PI-516 Had Shifted Low by 2%.Defective Fisher Porter Model 50EP1041 Bcxa Replaced & Channel Returned to Svc + (ML19305D790)
- ML19305D791 + (ML19305D791)
- 05000327/LER-1980-005, Forwards LER 80-005/03L-0 + (ML19305D792)
- ML19305D793 + (ML19305D793)