- 05000324/LER-1980-024-03, /03L-0:on 800311,while Decontaminating Torus in Preparation for Mods,Coating Found Blistered Under Normal Water Line.Caused by Demineralized Water Entrapped Between Steel Liner & Coating.Samples to Be Tested in DBA Environ + (ML19305D720)
- ML19305D721 + (ML19305D721)
- ML19305D722 + (ML19305D722)
- 05000366/LER-1980-017, Forwards LER 80-017/03L-0 + (ML19305D723)
- ML19305D724 + (ML19305D724)
- ML19305D725 + (ML19305D725)
- ML19305D726 + (ML19305D726)
- 05000254/LER-1980-008, Forwards LER 80-008/03L-0 + (ML19305D727)
- ML19305D728 + (ML19305D728)
- 05000366/LER-1980-017-03, /03L-0:on 800219,during Instrument Check,B Drywell Dihydrogen Dioxide Recorder Found Reading Low.Caused by Diaphragm Failure in B Analyzer Vacuum Pump.Diaphragms Replaced.Analyzer Recalibr & Returned to Svc + (ML19305D729)
- ML19305D730 + (ML19305D730)
- 05000254/LER-1980-007, Forwards LER 80-007/03L-0 + (ML19305D731)
- ML19305D732 + (ML19305D732)
- ML19305D733 + (ML19305D733)
- 05000254/LER-1980-007-03, /03L-0:on 800308,while Performing Control Room Insp & Panel Check,B Main Steam Line Radiation Monitor Found Reading Low.Caused by Logarithmic Radiation Monitor Chassis Electronically Drifting Out of Calibr.Chassis Recalibr + (ML19305D735)
- 05000254/LER-1980-008-03, /03L-0:on 800308,after Performing Preventive maint,1/2 Diesel Generator Would Not Start from Control Room.Caused by Poor Electrical Contact Between Fuse & Clip. Fuse Clip Adjusted + (ML19305D736)
- ML19305D737 + (ML19305D737)
- ML19305D738 + (ML19305D738)
- ML19305D739 + (ML19305D739)
- 05000304/LER-1980-013, Forwards LER 80-013/03L-0 + (ML19305D740)
- ML19305D742 + (ML19305D742)
- ML19305D743 + (ML19305D743)
- ML19305D744 + (ML19305D744)
- 05000366/LER-1980-031, Forwards LER 80-031/01T-0 + (ML19305D745)
- ML19305D746 + (ML19305D746)
- 05000304/LER-1980-013-03, /03L-0:on 800227,during Normal Operation,Maint Personnel Found Steam Generator Pressure Comparator 2PC-536A-B Shifted High by 1.5%.Caused by Defective Unit. Defective Unit Replaced W/Spare Unit + (ML19305D747)
- ML19305D748 + (ML19305D748)
- 05000366/LER-1980-031-01, /01T-0:on 800327,during Performance of 18-month Tests on Station Battery Chargers 2A,2B & 2C,chargers Were Unable to Maintain Load Limits.Caused by Imbalanced Silicon Control Rectifiers & Maladjusted Current Limit Module + (ML19305D749)
- 05000265/LER-1980-008, Forwards LER 80-008/03L-0 + (ML19305D750)
- ML19305D751 + (ML19305D751)
- 05000318/LER-1980-017, Forwards LER 80-017/03L-0 + (ML19305D752)
- ML19305D753 + (ML19305D753)
- ML19305D754 + (ML19305D754)
- ML19305D756 + (ML19305D756)
- ML19305D758 + (ML19305D758)
- 05000318/LER-1980-017-03, /03L-0:on 800316,saltwater Svc Water Heat Exchanger 22 Was Taken Out of Svc.Caused by Need to Repair Tube Leak.Tube Leak Found & Plugged + (ML19305D759)
- ML19305D760 + (ML19305D760)
- ML19305D762 + (ML19305D762)
- ML19305D763 + (ML19305D763)
- ML19305D764 + (ML19305D764)
- ML19305D765 + (ML19305D765)
- ML19305D766 + (ML19305D766)
- ML19305D767 + (ML19305D767)
- ML19305D768 + (ML19305D768)
- ML19305D769 + (ML19305D769)
- IR 05000341/1980002 + (ML19305D770)