- 05000029/LER-1980-003, Forwards LER 80-003/03L-0 + (ML19296B373)
- 05000029/LER-1980-003-03, /03L-0:on 800118,while Performing Radioactive Source Inventory & Leak Testing Procedure,Discovered That 121.8 Uci of Cs-137 Sealed Source Had Not Been Inventoried or Leak Tested Since 781213.Caused by Procedural Failure + (ML19296B379)
- ML19296B382 + (ML19296B382)
- 05000333/LER-1980-014, Forwards LER 80-014/03L-0 + (ML19296B384)
- ML19296B385 + (ML19296B385)
- 05000029/LER-1980-004, Forwards LER 80-004/03L-0 + (ML19296B386)
- 05000336/LER-1980-001, Forwards LER 80-001/03L-0 + (ML19296B389)
- ML19296B390 + (ML19296B390)
- ML19296B391 + (ML19296B391)
- 05000029/LER-1980-004-03, /03L-0:on 800119,during Scheduled Shutdown,While Performing Secondary Plant Chemistry,Steam Generators 1,3 & 4 Chloride Concentration Was Above 0.5 Ppm.Caused by Steam Generators Chemical Hideout.Generators Drained + (ML19296B392)
- 05000333/LER-1980-014-03, /03L-0:on 800116,during Normal Operation,Torus Water Level Limits Exceeded Tech Specs for 20 Minutes. Caused by Testing of HPCI Sys,Adding Water to Torus Via Min Flow Valve.Torus Pumped Down to Tech Spec Limit + (ML19296B393)
- ML19296B394 + (ML19296B394)
- ML19296B395 + (ML19296B395)
- ML19296B396 + (ML19296B396)
- 05000336/LER-1980-001-03, /03L-0:on 800118,during Routine Insurance Insp Testing W/Plant at 100% Power,Turbine Driven Auxiliary Feedwater Pump Became Inoperable Due to Failure of Turbine Inboard,Outboard & Thrust Bearings.Caused by Excessive Wear + (ML19296B398)
- ML19296B399 + (ML19296B399)
- ML19296B401 + (ML19296B401)
- ML19296B403 + (ML19296B403)
- ML19296B404 + (ML19296B404)
- ML19296B405 + (ML19296B405)
- 05000324/LER-1980-013, Forwards LER 80-013/03L-0 + (ML19296B407)
- ML19296B408 + (ML19296B408)
- ML19296B409 + (ML19296B409)
- ML19296B412 + (ML19296B412)
- ML19296B413 + (ML19296B413)
- 05000029/LER-1980-002, Forwards LER 80-002/03L-0 + (ML19296B414)
- 05000324/LER-1980-013-03, /03L-0:on 800116,during Normal Operation, Containment Atmospheric Monitor CAC-AQH-1260 Monitor Breaker Had Tripped on Magnetics Rendering CAC-AQH-1262-2 Inoperable.Caused by Short in Power Lead.Lead Taped + (ML19296B416)
- 05000324/LER-1980-012, Forwards LER 80-012/03L-0 + (ML19296B417)
- ML19296B418 + (ML19296B418)
- ML19296B419 + (ML19296B419)
- ML19296B420 + (ML19296B420)
- 05000029/LER-1980-002-03, /03L-0:on 800116,during Normal Operation,Primary Vent Stack Iodine Monitor Failed.Caused by Natural end-of- Life of One Pump Motor Bearing.Pump Motor Replaced + (ML19296B421)
- ML19296B422 + (ML19296B422)
- 05000324/LER-1980-012-03, /03L-0:on 800116,while Performing Torus Water Level Calibr & Functional Check,Level Switch E41-LSH-NOI5A Would Not Actuate.Caused by Switch Out of Calibr.Instrument Recalibr + (ML19296B423)
- 05000348/LER-1980-005, Forwards LER 80-005/03L-0 + (ML19296B424)
- ML19296B425 + (ML19296B425)
- 05000293/LER-1980-004, Forwards LER 80-004/01T-0 + (ML19296B426)
- ML19296B427 + (ML19296B427)
- 05000333/LER-1980-013, Forwards LER 80-013/03L-0 + (ML19296B428)
- ML19296B429 + (ML19296B429)
- ML19296B430 + (ML19296B430)
- ML19296B432 + (ML19296B432)
- 05000348/LER-1980-005-03, /03L-0:on 800118,during Solid State Protection Sys Operability Test on B Train SSPS,1B Steam Generator Level Logic Failed Logic Test Requirements.Caused by Failed Universal Card in B Train Ssps + (ML19296B433)
- 05000333/LER-1980-013-03, /03L-0:800114,during Surveillance Testing,Reactor lo-lo-lo Level Switch a Operated Improperly.Caused by Improper Closing of Level Switch Contact at Switch Set Point.Switch Replaced + (ML19296B434)
- ML19296B436 + (ML19296B436)
- ML19296B437 + (ML19296B437)
- ML19296B438 + (ML19296B438)