- 05000333/LER-1980-017-03, /03L-0:on 800130,drywell-to-torus Differential Pressure Did Not Meet 1.7 Psi Requirements of Tech Specs for Approx 1-h.Caused by Rapid Temp Decrease in Drywell Cooling Sys.Nitrogen Added,Restoring Pressure to Normal + (ML19294B469)
- ML19294B470 + (ML19294B470)
- 05000029/LER-1980-006, Forwards LER 80-006/03L-0 + (ML19294B471)
- 05000029/LER-1980-006-03, /03L-0:on 800126,while Performing Safety Injection Safety Valve Setpoint Check Procedure,Safety Valve Failed to Open.Caused by Dirty Internals.Safety Valve Was Disassembled,Cleaned & Successfully Tested + (ML19294B473)
- ML19294B474 + (ML19294B474)
- 05000298/LER-1980-004, Forwards LER 80-004/03L-0 + (ML19294B475)
- ML19294B476 + (ML19294B476)
- 05000298/LER-1980-004-03, /03L-0:on 800115,during Normal Operation, Discovered That RHR Valve M018 Was Inoperable.Caused by Failure of GE Relay Coil,Blowing Valve Control Circuit Fuse. Relay Coil Was Replaced & Correct Operation Verified + (ML19294B477)
- ML19294B478 + (ML19294B478)
- ML19294B479 + (ML19294B479)
- ML19294B480 + (ML19294B480)
- ML19294B481 + (ML19294B481)
- ML19294B482 + (ML19294B482)
- ML19294B483 + (ML19294B483)
- ML19294B485 + (ML19294B485)
- 05000336/LER-1980-003, Forwards LER 80-003/03L-0 + (ML19294B486)
- ML19294B487 + (ML19294B487)
- ML19294B488 + (ML19294B488)
- 05000336/LER-1980-003-03, /03L-0:on 800122,during Routine Power Operation, Containment Air Temp Found in Excess of 120F Limit.Caused by Adjustments to Svc Water Temp Control Valve for Reactor Bldg Closed Cooling Water Sys.Valve Readjusted + (ML19294B489)
- ML19294B490 + (ML19294B490)
- ML19294B491 + (ML19294B491)
- ML19294B492 + (ML19294B492)
- ML19294B494 + (ML19294B494)
- ML19294B495 + (ML19294B495)
- ML19294B496 + (ML19294B496)
- ML19294B497 + (ML19294B497)
- ML19294B499 + (ML19294B499)
- ML19294B500 + (ML19294B500)
- ML19294B502 + (ML19294B502)
- ML19294B504 + (ML19294B504)
- ML19294B505 + (ML19294B505)
- ML19294B506 + (ML19294B506)
- ML19294B507 + (ML19294B507)
- ML19294B508 + (ML19294B508)
- ML19294B509 + (ML19294B509)
- ML19294B510 + (ML19294B510)
- ML19294B511 + (ML19294B511)
- ML19294B512 + (ML19294B512)
- ML19294B516 + (ML19294B516)
- 05000271/LER-1980-007, Forwards LER 80-007/03L-0 + (ML19294B517)
- ML19294B518 + (ML19294B518)
- ML19294B519 + (ML19294B519)
- 05000271/LER-1980-007-03, /03L-0:on 800128,while Performing Surveillance Testing of HPCI Sys,Governor Valve Remained Shut After Turbine Was Shut Down W/Auxiliary Oil Pump Running.Caused by Actuator Sticking + (ML19294B520)
- ML19294B521 + (ML19294B521)
- ML19294B522 + (ML19294B522)
- 05000346/LER-1980-010, Forwards LER 80-010/01T-0 + (ML19294B523)
- ML19294B524 + (ML19294B524)
- ML19294B525 + (ML19294B525)
- 05000346/LER-1980-010-01, /01T-0:on 800214,reanalysis of RCS Pipe Restraints Per IE Insp Rept 50-346/79-23 Revealed Design Deficiency on Two Reactor Coolant Hot Leg Pipe Whip Restraints at Top of Each RCS Hot Leg.Caused by Design Error + (ML19294B526)
- 05000302/LER-1980-007, Forwards LER 80-007/03L-0 + (ML19294B527)
- ML19294B528 + (ML19294B528)