Docket No. 50-208
~
Columbia University ATTN: f4r. John ti. Harding Resident University Counsel 110 Low idemorial Library New York, New York 10027 Gentlemen:
On August 10, 1979, we sent IE Bulletin 79-19, " Packaging of Low-Level Radio-active Waste for Transport and Burial," to you for iaformation and action.
Item 9 of that Bulletin required you to report, in writing, within 45 days of receipt of the Bulletin, your plan of action and schedule with regard to Items 1 through 8 of the Bulletin.
Thus far, we do not have a record of your response to the Bulletin.
You are reminded that such response is required.
Authority and clearance for issuing the reporting requirements of the bulletin has been approved for the agency by the U. S. General Accounting Office.
Another copy of Bulletin 79-19 is enclosed for your use.
We request your prompt attention to this matter.
If you have already responded to Bulletin 79-19, please disregard this letter.
Sincerely,
& OC &
j Bdy e H. Urier Director Enclosure :
IE Bulletin No. 79-19 cc w/ encl:
Dr. W. W. Havens, Jr., Director of Nuclear Engineering 103 80030sa
ENCLOSURE 1 UtilTED STATES flUCLEAR REGULATORY C0rcilSSI0tt 0FFICE OF It1SPECTI0ft AND EtlFORCEMEtiT WASHIf1GT0tl, D.C.
20555 IE Bulletin fio. 79-19 Date: August 10, 1979 Page 1 of 3 PACKAGIt1G 0F LOW-LEVEL RADI0 ACTIVE WASTE FOR TRAtlSPORT AtlD BURIAL Description of Circumstances:
Low-level radioactive waste is that waste which can be transferred and shipped to one of three waste burial facilities which are located in and licensed by the Agreement States of Nevada, South Carolina, and Washington.
On July 10, 1979, the Governors of the three states notified t1RC Chairman Hendrie of the sericus and repeated disregard for rules governing the shipments of low-level radioactive wastes to these burial facilities.
Examples of violations of Agreement State, 00T and NRC rules follow:
Improperly packaged uranium fines igniting packaged liquid scintillation vials in combustible waste is believed to have caused a fire and destruction of a truck at the Beatty, Nevada burial facility on May 14, 1979.
On July 2, 1979, three of twelve steel containers shipped to the Beatty burial facility were found to be leaking radioactive material.
The material was describt on the bill of lading as being a solid inorganic salt (evaporator concentrates solidified with urea formaldehyde) from a reactor facility.
The Governor of the State of Nevada ordered the drums to be shipped out of the state and the burial facility was temporarily closed.
On July 30, the first shipment into the reopened Beatty facility contained free liquid in " solid" material.
'he radioactive contents were sand filters used at an insitu leaching process at a uranium mill.
Forty-three shipments with sixty-three deficiencies were cbserved during the package inspection program between April 10 and July 5,1979, by the Agreement State of South Carolina, at the Barnwell, S.C. burial facility.
The shipments were from reactor, medical, industrial and military facilities.
On June 28, 1979, the Federal Highway Administration issued a Notice of Violation to a reactor facility proposing-a $10,000 fine for truck contamination resulting from improper closures on 55-gallon drums of LSA material and for improper loading of the drums on the vehicle.
These are a few examples of shipments of radioactive material to burial facilities which did not fully meet NRC, DOT and Agreement State requirements which.ere developed to protect the health and safety of the public.
The Governors of the three States with licensed burial facilities have indicated that if the situation is not rectified, they may have to initiate actions which would deny use of the three burial sites by violators.
7
_l'ef b
_,,,C
' i'
.g.
IE Bulletin tio. 79-19 Date: August 10, 1979 Page 2 of 3 Sources of Infomation:
The 00T regulatory requirements can be found in 49 CFR Parts 170-179.
The fiRC regulatory requirements can be found in 10 CFR Parts 19 to 71.
The fiRC regu-latory requirements for Agreement State licensees in non-agreement states are in 10 CFR Part 150.
Copies of the regulations may be purchased from the Superintendent of Documents, U. S. Government Printing Office, Washington, D.C. 20402.
Infomation about licensing requirements for tiRC packages can be obtained from the flRC Transportation Branch (301-427-4122).
Information about 00T packaging and transport requirements can be obtained by calling the DOT Office of Hazardous Materials (202-426-2311).
Action To Be Taken By Licensees:
To assure the safe transfer, packaging, and transport of low-level radioactive waste, each licensee is expected to:
1.
Maintain a current set of D0T and t1RC regulations concerning the transfer, packaging and transport of low-level radioactive waste material.
2.
Maintain a current set of requirements (license) placed on the waste burial fim by the Agreement State of tievada, South Carolina, or Washington before I
(
packaging low-level radioactive waste material for transfer and shipment to the Agreement State licensee.
If a waste collection contractor is used, obtain the appropriate requirements from the contractor.
3.
Designate, in writing, people in your organization who are responsible for the safe transfer, packaging and transport of low-level radioactive material.
4.
Provide management-approved, detailed instructions and operating procedures to all personnel involved in the transfer, packaging and transport of Icw-level radioactive material.
Special attention should be given to controls on the chemical and physical fom of. the low-level radioactive material and on the containment integrity of the packaging.
5.
Provide training and periodic retraining in the DOT and iiRC regulatory requirements, the waste burial license requirements, and in your instruc-tions and operating procedures for all personnel involved in the transfer, packaging and. transport of radioactive material.
Maintain a record of training dates, attendees, and subject material for future inspections by fiRC personnel.
6.
Provide training and periodic retraining to those employees who operate the processes which generate waste to assure that the volume of low-level radioactive waste is minimized and that such waste is processed into acceptable chemical ano physical fom for transfer and shipment to a icw-level radioactive waste burial facility.
1 IE Bulletin flo. 79-19 Date: August 10, 1979 Page 3 of 3 7.
Establish and implement a management-controlled audit function of all transfer, packaging and transport activities to provide assurance that personnel, instructions and procedures, and process and transport equipment are functioning to ensure safety and compliance with regulatory require-ments.
8.
Perform, within 60 days of the date of this bulletin, a management-controlled audit of your activities associated with the transfer, pack;gi.'g and trans-port of low-level radioactive waste.
Maintain a record of all audits for future inspections by f(RC or 00T inspectors.
(flote: If your have an estab-lished audit function and have performed such an audit of all activities in Items 1-6 within the past six months, this audit requirement is satisfied.)
9.
Report, in writing within 45 days, your plan of action and schedule with regard to the above items.
In addition, provide responses to the three questions below.
Reports should be submitted to the Director of the appropriate 11RC Regional Office and a copy should be forwarded to the 11RC Office of Inspection and Enforcement, Division of Fuel Facility and Materials Safety Inspection, Washington, D.C.
20555.
Provide answers for 1978 and fo' r the first six months of 1979 to' the following questions:
1.
(
How many low-level radioactive waste shipments did you make? What was the volume of low-level radioactive waste shipped?
(Power reactor licensees who report this information in accordance with Te~chnical Specifications do not need to respond to this question.)
2.
What was the quantity (curies) of low-level radioactive waste shipped?
What were the major isotopes in the low-level radioactive waste?
(Power reactor licensees who report this information in accordance with Technical Specifications do not need co respond to this question.)
3.
Did you generate liquid low-level radioact.ive waste?
If the answer is
'yes,' what process was used to solidify the liquid waste?
Licensees who do not generate low-level radioactive waste should so indicate in their responses and do not need to take other actions specified in the above items.
Approved by GAO, B180225 (R0072'); clearance expires 7-31-80.
Approval was given under a blanket clearance specifically for identified generic problems.