- 05000301/LER-1979-002, Forwards LER 79-002/03L-0 + (ML19276F324)
- ML19276F325 + (ML19276F325)
- 05000254/LER-1979-013, Forwards LER 79-013/03L-0 + (ML19276F326)
- ML19276F327 + (ML19276F327)
- 05000304/LER-1979-010-03, /03L-0 on 790214:Channel 2LT-460 Greater than 6% from Channel 2LT-461.Caused by Transmitter Had Zero & Span Shifted.Zero Adjustment Made,Transmitter Conservative for High & Low Level Trips + (ML19276F328)
- 05000301/LER-1979-002-03, /03L-0 on 790227:during Biweekly Test of a Reactor Trip Breaker,Several Seconds Elapsed Following Trip Signal Before Breaker Tripped.Caused by Faulty Reactor Trip Relay,Westinghouse BFD31.Relay Replaced + (ML19276F329)
- 05000254/LER-1979-013-03, /03L-0 on 790217:check Valves 1-263-2-31B & 1-263-42A Failed to Check Flow Through Instrument Lines. Caused by Dirt in Valve Internals.Internals Removed,Cleaned & Reassembled + (ML19276F330)
- ML19276F331 + (ML19276F331)
- ML19276F332 + (ML19276F332)
- ML19276F333 + (ML19276F333)
- ML19276F334 + (ML19276F334)
- ML19276F335 + (ML19276F335)
- 05000333/LER-1979-014, Forwards LER 79-014/01T-0 + (ML19276F337)
- ML19276F339 + (ML19276F339)
- 05000265/LER-1979-004, Forwards LER 79-004/03L-0 + (ML19276F340)
- ML19276F341 + (ML19276F341)
- 05000304/LER-1979-009, Forwards LER 79-009/03L-0 + (ML19276F342)
- 05000333/LER-1979-014-01, /01T-0 on 790312:calculations in Piping Stress Analysis Are Being Redone on Accelerated Basis by Architect/Engineer.Shutdown Will Continue Until All Problems Are Resolved.Final Rept on Matter Is Forthcoming + (ML19276F344)
- ML19276F345 + (ML19276F345)
- 05000265/LER-1979-004-03, /03L-0 on 790211:suction Isolation Valve Mo 2-1001-50 Failed to Close from Control Room.Caused by Failed Circuit Breaker in Valve Motor Control Center. Valve Taken Out of Svc for Repair During Outages + (ML19276F346)
- ML19276F347 + (ML19276F347)
- 05000304/LER-1979-009-03, /03L-0 on 790210:MSIV Partially Opened.Hydraulic Pump Was Reenergized,Causing MSIV to Reclose.Cause Was Combination of Drain Valve Not Opening After MSIV Closure & Open Accumulator Leaking Gas + (ML19276F348)
- ML19276F349 + (ML19276F349)
- ML19276F350 + (ML19276F350)
- ML19276F351 + (ML19276F351)
- ML19276F352 + (ML19276F352)
- ML19276F353 + (ML19276F353)
- ML19276F354 + (ML19276F354)
- ML19276F355 + (ML19276F355)
- ML19276F357 + (ML19276F357)
- ML19276F358 + (ML19276F358)
- ML19276F359 + (ML19276F359)
- ML19276F363 + (ML19276F363)
- ML19276F370 + (ML19276F370)
- ML19276F374 + (ML19276F374)
- ML19276F377 + (ML19276F377)
- ML19276F380 + (ML19276F380)
- 05000254/LER-1979-003-03, /03L-1 on 790119:MSIV Local Leak Rate Showed Seven Valves Leaking Excessively.Causes Unspecified.Valve Stroke Adjusted,Certain Valves Dismantled,Discs & Seats Were Lapped & Machined + (ML19276F389)
- 05000318/LER-1979-009, Forwards LER 79-009/03L-0 + (ML19276F391)
- ML19276F392 + (ML19276F392)
- 05000318/LER-1979-009-03, /03L-0 on 790226:svc Water Heat Exchanger Saltwater Outlet Throttle Valve 21 Failed to Open on Signal.Cause Unknown.Valve Will Be Repaired During Next Outage + (ML19276F394)
- ML19276F396 + (ML19276F396)
- ML19276F398 + (ML19276F398)
- ML19276F399 + (ML19276F399)
- ML19276F400 + (ML19276F400)
- ML19276F427 + (ML19276F427)
- ML19276F428 + (ML19276F428)
- ML19276F431 + (ML19276F431)
- ML19276F433 + (ML19276F433)
- ML19276F443 + (ML19276F443)
- ML19276F448 + (ML19276F448)