Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19260C319 + (ML19260C319)
- ML19260C320 + (ML19260C320)
- ML19260C321 + (ML19260C321)
- ML19260C322 + (ML19260C322)
- ML19260C323 + (ML19260C323)
- ML19260C325 + (ML19260C325)
- ML19260C327 + (ML19260C327)
- ML19260C328 + (ML19260C328)
- ML19260C329 + (ML19260C329)
- ML19260C330 + (ML19260C330)
- 05000312/LER-1979-004, Forwards LER 79-004/04T-0 + (ML19260C331)
- ML19260C333 + (ML19260C333)
- ML19260C334 + (ML19260C334)
- 05000312/LER-1979-004-04, /04T-0:on 791203,plant Effluent Samples Indicated Chlorine Levels Exceeded Tech Spec Limits.Caused by Partial Blockage of Sewage Sys Inlet Line.Dilution Flow Increased & Sewage Sys Hypochlorite Pump Stroke Reduced + (ML19260C335)
- Inspection Manual Change Notice 19-028, + (ML19260C336)
- ML19260C337 + (ML19260C337)
- 05000366/LER-1979-126, Forwards LER 79-126/03L-0 + (ML19260C338)
- ML19260C339 + (ML19260C339)
- ML19260C340 + (ML19260C340)
- 05000366/LER-1979-126-03, /03L-0:on 791121,during Plant Svc Water Pump Operability Test,Svc Water Pump Failed to Meet ASME Section II Requirements.Caused by Distortion of Impeller by Metal Foreign Object.Pump Rebuilt + (ML19260C341)
- ML19260C342 + (ML19260C342)
- ML19260C343 + (ML19260C343)
- 05000312/LER-1979-019, Forwards LER 79-019/03L-0 + (ML19260C345)
- 05000312/LER-1979-019-03, /03L-0:on 791125,during Routine Plant Equipment Insp,Discovered Weld Leak on Seal Injection Line.Cause Not Stated.Defective Portion of Weld Ground Out & Weld Dye Penetrant Checked + (ML19260C347)
- ML19260C348 + (ML19260C348)
- ML19260C349 + (ML19260C349)
- ML19260C350 + (ML19260C350)
- ML19260C353 + (ML19260C353)
- 05000346/LER-1979-105, Revised LER 79-105/01T-1:on 791109,during Review of IE Bulletin 79-21 Response,Noted Steam Generator Low Level Trip Setpoints to Steam & Feedwater Rupture Control Sys Channels 1 & 2 Were Below Tech Specs.Caused by Error in Poin + (ML19260C354)
- ML19260C356 + (ML19260C356)
- ML19260C357 + (ML19260C357)
- 05000302/LER-1979-107, Forwards LER 79-107/03L-0 + (ML19260C358)
- ML19260C359 + (ML19260C359)
- ML19260C360 + (ML19260C360)
- ML19260C361 + (ML19260C361)
- ML19260C362 + (ML19260C362)
- 05000302/LER-1979-107-03, /03L-0:on 791120,following Routine Pressurizer Sampling,Chemical Addition Isolation Valve Would Not Close. Caused by Inadequate Design.Installed Mod 79-11-81 Providing Pneumatic Assist During Valve Closing + (ML19260C363)
- ML19260C364 + (ML19260C364)
- ML19260C365 + (ML19260C365)
- ML19260C366 + (ML19260C366)
- 05000321/LER-1979-095, Forwards LER 79-095/03L-0 + (ML19260C367)
- ML19260C368 + (ML19260C368)
- 05000321/LER-1979-095-03, /03L-0:on 791126,during Normal Plant Operation, Discovered That 791126 Battery Individual Cell Surveillance Procedure Not Performed.Caused by Personnel Oversight. Procedure Performed on 791127 + (ML19260C369)
- 05000346/LER-1979-112, Forwards LER 79-112/03L-0 + (ML19260C371)
- ML19260C372 + (ML19260C372)
- ML19260C373 + (ML19260C373)
- ML19260C374 + (ML19260C374)
- 05000346/LER-1979-112-03, /03L-0:on 791119,valve MS106 Failed to Open During Surveillance Testing.Caused by Improper Installation of Worm Gear Spacer.Drive Sleeve Machined & Worm Gear Spacer Reinstalled + (ML19260C375)
- ML19260C376 + (ML19260C376)
- ML19260C377 + (ML19260C377)
- ML19260C378 + (ML19260C378)