%....,d,8 611 RYAN PLAZA DRIVE, SUITE 1000 ARLINGTON, TEXAS 76012
+
S 0 AUG 1979 Docket No. 99900526/79-02 Black & Veatch Consulting Engineers Attn:
Mr. P. J. Adam Head, Power Division Post fice Lox 8405 Kanu ity, Missouri 64114 Gentlemen:
This refers to the QA Program Inspection conducted by Mr. R. H. Erickley of this office on August 6-10, 1979, of your 'acility at Overland Park, Kansas, and to the discussions of our findings with Mr. R. M. Butcher and members of your staff at the conclusion of the inspection.
Areas examined during the QA program inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.
During this inspection it was found that the imple=entation of your QA program failed to meet certain of your commitments. The specific findings and references to the pertinent commitments are identified in the enclo-sures to this letter.
Please provide us within thirty (30) days a written statement containing, (1) a description of steps that have been or will be taken to correct these findings, (2) a description of steps that have been or will be taken to prevent recurrence, and (3) the dates your corrective actions and pre-ventive measures were or will be completed.
In accordance with Section 2.790 of the Commission's Rules of Practice, Part 2, Title 10, Code of Federal Regulations, a copy of this letter with enclosure and your reply together with the enclosed inspection report will be placed in the Commission's Public Document Room. If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is 1617 012 7912 60
.tlp 2 63 2
~ Black and Veatch Consulting Engineers contained in a separate part of the document.
If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely,
}.
J
,33 x Uldis Potapovh,s L m n
Chiyf Vendor Inspection Branch
Enclosures:
1.
Notice of Deviation 2.
Inspection Report No. 99900526/79-02 1617 013
.