Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19209C584 + (ML19209C584)
- ML19209C585 + (ML19209C585)
- IR 05000293/1979011 + (ML19209C587)
- IR 05000309/1970007 + (ML19209C588)
- ML19209C589 + (ML19209C589)
- ML19209C594 + (ML19209C594)
- ML19209C596 + (ML19209C596)
- ML19209C606 + (ML19209C606)
- ML19209C607 + (ML19209C607)
- 05000333/LER-1979-072, Forwards LER 79-072/03L-0 + (ML19209C608)
- ML19209C609 + (ML19209C609)
- ML19209C611 + (ML19209C611)
- ML19209C612 + (ML19209C612)
- 05000333/LER-1979-072-03, /03L-0:on 790912,root Valves Not Verified in Proper Position.Caused by Temporary Change in Procedures to Verify Proper Position in Accordance W/Plant Administrative Controls.Double Verification Program Initiated + (ML19209C614)
- ML19209C615 + (ML19209C615)
- ML19209C616 + (ML19209C616)
- ML19209C617 + (ML19209C617)
- 05000338/LER-1979-115-03, /03L-0:on 790913,loop B Steam Indicator Read Lower than Redundant Indicator.Caused by Leaking of Transmitter Root Valves Resulting in Loss of Ref Leg Level.Steam Flow Channel Tripped & Loop Calibr + (ML19209C618)
- 05000338/LER-1979-117-03, /03L-0:on 790913,excessive Steam Observed Leaking Past Seat of Trip Valve TV-MS111A.Caused by Valve Not Fully Seating.Seating Surfaces Were Cleaned & Gaskets Replaced + (ML19209C619)
- 05000338/LER-1979-118-03, /03L-0:on 790914,temp of Steam Generator B Support Fell Below Tech Spec Limit.Caused by Personnel Error While Operating Support Heaters Manually.Heaters Energized to Increase Temp + (ML19209C620)
- 05000338/LER-1979-119-03, /03L-0:on 790914,high Steam Line Differential Pressure Loop 2 Channel II Bistable Failed to Trip During Surveillance Test.Caused by Loose Lead on Signal Comparator Card.Card Replaced & New One Calibr + (ML19209C621)
- 05000271/LER-1979-022, Forwards LER 79-022/03L-0 + (ML19209C622)
- ML19209C623 + (ML19209C623)
- 05000271/LER-1979-022-03, /03L-0:on 790911,halogenated Hydrocarbon Removal Efficiency Found to Be Less than Tech Specs.Caused by Excessive Carbon Filter Leakage.Charcoal Was Removed & Replaced + (ML19209C624)
- ML19209C625 + (ML19209C625)
- ML19209C626 + (ML19209C626)
- ML19209C627 + (ML19209C627)
- ML19209C628 + (ML19209C628)
- ML19209C629 + (ML19209C629)
- ML19209C630 + (ML19209C630)
- ML19209C631 + (ML19209C631)
- 05000348/LER-1979-038-03, /03L-0:on 790912,while Performing Surveillance Test FNP-1-STP-1.0,containment Gaseous Activity Purge & Exhaust Isolation Monitor Declared Inoperable.Caused by Monitor Bypass Valve Being in Open Position + (ML19209C633)
- ML19209C634 + (ML19209C634)
- 05000348/LER-1979-039-03, /03L-0:on 790924,fuel Storage Pool Area Radiation Monitor Declared Inoperable Due to Reading Discrepancy. Caused by Instrument Drift.Monitor Recalibr & Returned to Svc on 790930 + (ML19209C635)
- ML19209C636 + (ML19209C636)
- ML19209C637 + (ML19209C637)
- ML19209C638 + (ML19209C638)
- ML19209C639 + (ML19209C639)
- ML19209C641 + (ML19209C641)
- ML19209C643 + (ML19209C643)
- ML19209C645 + (ML19209C645)
- ML19209C646 + (ML19209C646)
- ML19209C648 + (ML19209C648)
- ML19209C649 + (ML19209C649)
- ML19209C651 + (ML19209C651)
- ML19209C652 + (ML19209C652)
- ML19209C653 + (ML19209C653)
- ML19209C654 + (ML19209C654)
- ML19209C655 + (ML19209C655)
- ML19209C658 + (ML19209C658)
- ML19209C660 + (ML19209C660)