- 05000313/LER-1979-015-99, /99X-0:on 790817,as Result of Analysis of Seismic Category I Pipe supports,37 Restraints Were Identified to Have Safety Factor of Less than Two.Supports Modified + (ML19208D472)
- ML19208D474 + (ML19208D474)
- 05000333/LER-1979-052-04, /04L-0:on 790830,computer Calculations for Condenser Inlet Water & Plant Cooling Water Discharge Temp Differential Temp Were Found Out of Calibr.Cause Not Stated. Instruments Recalibr within Tech Specs Limits + (ML19208D475)
- 05000298/LER-1979-023, Forwards LER 79-023/03L-0 + (ML19208D476)
- ML19208D477 + (ML19208D477)
- ML19208D478 + (ML19208D478)
- 05000313/LER-1979-016-03, /03L-0:on 790827,diesel Generator 2 Tripped on Low Oil Pressure,Rendering Generator Inoperable.Caused by Leak Allowing Water to Enter Oil Sys,Causing High Crankcase Pressure.Oil Cooler Replaced + (ML19208D479)
- 05000324/LER-1979-080, Forwards LER 79-080/03L-0 + (ML19208D480)
- ML19208D481 + (ML19208D481)
- 05000324/LER-1979-080-03, /03L-0:on 790830,primary Containment Ambient Temp Exceeded Tech Spec Limits,Causing Small Steam Leak.Caused by Leakage & Steam Cut of King Pin Cover on Feedwater Check Valve B21-F010B.Leak Repaired & Leakage Decreased + (ML19208D484)
- ML19208D487 + (ML19208D487)
- 05000298/LER-1979-023-03, /03L-0:on 790809,Barton Model 288 Differential Pressure Indicating Switch MS-DPIS-119B Was Found in Excess of Tech Specs Table 3.2.A.Caused by Faulty Switch. Microswitch Assembly Was Replaced + (ML19208D488)
- 05000324/LER-1979-078, Forwards LER 79-078/03L-0 + (ML19208D489)
- ML19208D490 + (ML19208D490)
- ML19208D491 + (ML19208D491)
- ML19208D492 + (ML19208D492)
- ML19208D493 + (ML19208D493)
- 05000324/LER-1979-078-03, /03L-0:on 790831,while Removing Rwcv,Suction Inboard Value F001 Failed in mid-position.Caused by Torque Limit Switch Opening & Causing Motor to Stop.Valve Tested & Problem Did Not Recur.No Further Action Necessary + (ML19208D494)
- ML19208D495 + (ML19208D495)
- ML19208D496 + (ML19208D496)
- ML19208D498 + (ML19208D498)
- ML19208D499 + (ML19208D499)
- ML19208D500 + (ML19208D500)
- ML19208D501 + (ML19208D501)
- ML19208D502 + (ML19208D502)
- ML19208D504 + (ML19208D504)
- ML19208D506 + (ML19208D506)
- ML19208D507 + (ML19208D507)
- 05000334/LER-1979-030-03, /03L-0:on 790823,containment Air Lock Surveillance Test Not Performed as Required.Caused by Failure of Operations Personnel to Perform Surveillance Test.Operating Supervisors Instructed to Be More Aware + (ML19208D508)
- ML19208D509 + (ML19208D509)
- ML19208D510 + (ML19208D510)
- 05000334/LER-1979-033-03, /03L-0:on 790824,nuclear Instrumentation Sys Power Range Low Power Trip Logic Inoperable.Caused by Faulty Logic Board for Low Power Trip.Logic Board Replaced & Surveillance Test Completed Satisfactorily + (ML19208D511)
- ML19208D512 + (ML19208D512)
- 05000334/LER-1979-035-03, /03L-0:on 790430,during 18-month Surveillance testing,23 Snubbers Had lock-up or Bleed Rate Values Outside of Acceptance Criteria.Caused by Air in Cylinder,Wear Ring Problems & Handling Damage.Snubbers Rebuilt + (ML19208D513)
- ML19208D514 + (ML19208D514)
- ML19208D516 + (ML19208D516)
- ML19208D517 + (ML19208D517)
- ML19208D518 + (ML19208D518)
- ML19208D519 + (ML19208D519)
- ML19208D520 + (ML19208D520)
- ML19208D521 + (ML19208D521)
- ML19208D522 + (ML19208D522)
- ML19208D523 + (ML19208D523)
- ML19208D524 + (ML19208D524)
- ML19208D525 + (ML19208D525)
- IR 05000334/1979005 + (ML19208D526)
- ML19208D527 + (ML19208D527)
- ML19208D529 + (ML19208D529)
- IR 05000302/1977002 + (ML19208D532)
- ML19208D534 + (ML19208D534)
- ML19208D537 + (ML19208D537)