Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18153A169 + (ML18153A169)
- 05000280/LER-1997-007, Forwards LER 97-007-00,per 10CFR50.73.Commitments Contained in Ltr,Listed + (ML18153A170)
- ML18153A171 + (ML18153A171)
- 05000280/LER-1997-007-01, :on 970930,determined That Plant Was Outside App R Design Basis Due to Vital Bus Isolation Issue.Caused by Personnel Error.Installed Circuit Protective Device During Oct 1997 Refueling Outage + (ML18153A172)
- ML18153A174 + (ML18153A174)
- ML18153A176 + (ML18153A176)
- 05000280/LER-1997-008, Forwards LER 97-008-00 Re Invalid Actuation Esfs,Due to Personnel Errors.Lessons Learned from Event Will Be Presented to Safety Preparers/Reviewers + (ML18153A177)
- ML18153A178 + (ML18153A178)
- 05000280/LER-1997-008-01, :on 971011,invalid Actuation of ESF Occurred. Caused by Personnel Errors.Main CR Bottled Air Sys Isolated & Containment Hydrogen Analyzer Heat Tracing Actuation Signal Reset + (ML18153A179)
- ML18153A180 + (ML18153A180)
- ML18153A182 + (ML18153A182)
- ML18153A186 + (ML18153A186)
- ML18153A187 + (ML18153A187)
- ML18153A188 + (ML18153A188)
- ML18153A190 + (ML18153A190)
- 05000280/LER-1997-011, :on 971030,determined That Periodic Test Procedures for Testing Reactor Trip Bypass Breakers Did Not Test Manual Undervoltage Trip.Caused by mis-interpretation of Term in-service. Procedures Revised + (ML18153A191)
- 05000280/LER-1997-010, :on 971028,discovered Missed Fire Protection Surveillance Pt.Caused by Personnel Error.Satisfactorily Completed PT Procedure 0-OPT-FP-009 & Diesel Driven Fire Pump 1-FP-P-2 Declared Operable + (ML18153A192)
- ML18153A193 + (ML18153A193)
- ML18153A194 + (ML18153A194)
- ML18153A196 + (ML18153A196)
- ML18153A204 + (ML18153A204)
- 05000280/LER-1997-012-01, Forwards LER 97-012-01,per 10CFR50.73.Commitments Made by Util,Listed + (ML18153A205)
- ML18153A206 + (ML18153A206)
- 05000280/LER-1997-012, :on 971028,loss of Power to Latching Mechanism on Several Doors Occurred.Caused by Tripping of Two Breakers in Security Distribution Panel.Reset Affected Breakers Which Restored Power to Security Systems & Affected Doors + (ML18153A207)
- 05000280/LER-1997-009-01, Forwards LER 97-009-01,per 10CFR50.73.Commitments Made by Util,Listed + (ML18153A208)
- ML18153A209 + (ML18153A209)
- 05000280/LER-1997-009, :on 971014,declared Intake Canal Level Probes Inoperable Due to Marine Growth.Caused by Inadequate Maint of Intake Canal Level Probes.Subject Probes Were Cleaned, Tested Satisfactorily & Returned to Operable Status + (ML18153A210)
- ML18153A211 + (ML18153A211)
- ML18153A212 + (ML18153A212)
- ML18153A213 + (ML18153A213)
- ML18153A215 + (ML18153A215)
- ML18153A216 + (ML18153A216)
- ML18153A217 + (ML18153A217)
- ML18153A218 + (ML18153A218)
- ML18153A219 + (ML18153A219)
- 05000280/LER-1998-001-01, :on 980108,deficient Test Due to Faulty Test Equipment Resulted in TS Violation.Caused by Faulty Vibration Analyzer Cable or Loose Connection.Station Deviation Rept Was Submitted + (ML18153A220)
- ML18153A224 + (ML18153A224)
- 05000280/LER-1998-002, :on 980202,automatic Turbine Trip Resulted in Automatic Reactor Trip.Caused Degraded Generator Voltage Regulator sub-component Failure.Placed Plant in Safe Hot SD & Replaced Intermittent Relay & Relay Socket + (ML18153A225)
- ML18153A226 + (ML18153A226)
- ML18153A227 + (ML18153A227)
- ML18153A229 + (ML18153A229)
- 05000280/LER-1998-004, :on 980206,fire Watch Was Released Prematurely Resulting in Violation of Ts.Caused by Inadequate Planning of Repair Activity.Work Orders Will Include Ref to Applicable Procedures Developed to Assist in Repairs + (ML18153A230)
- ML18153A233 + (ML18153A233)
- 05000280/LER-1998-003, :on 980226,no Procedural Guidance for Maintaining EDG Minimum Fuel Supply During Loop,Was Identified.Caused by Absence of Procedural Instructions. Deviation Rept Submitted to Document Deviating Condition + (ML18153A234)
- ML18153A235 + (ML18153A235)
- ML18153A236 + (ML18153A236)
- ML18153A238 + (ML18153A238)
- ML18153A242 + (ML18153A242)
- ML18153A244 + (ML18153A244)
- ML18153A245 + (ML18153A245)
- ML18153A246 + (ML18153A246)