- ML18095A396 + (ML18095A396)
- ML18095A397 + (ML18095A397)
- IR 05000272/1990018 + (ML18095A399)
- ML18095A403 + (ML18095A403)
- ML18095A405 + (ML18095A405)
- ML18095A406 + (ML18095A406)
- ML18095A407 + (ML18095A407)
- ML18095A408 + (ML18095A408)
- ML18095A409 + (ML18095A409)
- 05000272/LER-1989-004, :on 890120,discovered That Tech Spec Surveillance Table 4.3-1 Number 20,not Performed as Required.Probably Caused by Inadequate Administrative Controls.Procedure Issued on Status Test + (ML18095A410)
- PMNS20180447, Discussion of Requests for Additional Information Responses Related to the River Bend License Renewal Application + (ML18095A412)
- ML18095A413 + (ML18095A413)
- ML18095A415 + (ML18095A415)
- ML18095A416 + (ML18095A416)
- ML18095A418 + (ML18095A418)
- 05000272/LER-1990-022-01, :on 900717,observed That Relief Valve 1SJ167 Was Leaking Past Seat as Result of Investigation to Determine Cause of Decreasing Level in Accumulators.Caused by Equipment Failure.Valve Repaired on 900722 + (ML18095A421)
- 05000272/LER-1989-035, :on 891210,containment Compressed Air Supply Valve Found Untagged in Open Position During Mode Changes. Caused by Personnel Error.Procedure IOP-2 Revised to Include Step to Verify Valve 1SA118 Closed + (ML18095A422)
- ML18095A423 + (ML18095A423)
- 05000272/LER-1990-021-01, :on 900717,discovered That Work Order Not Issued to Perform Revised Procedure 1IC-16.1.008.Caused by Personnel Error.Event Reviewed by Technical Department Mgt Appropriate Personnel + (ML18095A424)
- ML18095A425 + (ML18095A425)
- ML18095A427 + (ML18095A427)
- ML18095A429 + (ML18095A429)
- ML18095A430 + (ML18095A430)
- ML18095A431 + (ML18095A431)
- ML18095A432 + (ML18095A432)
- ML18095A433 + (ML18095A433)
- ML18095A434 + (ML18095A434)
- IR 05000272/1990200 + (ML18095A435)
- ML18095A437 + (ML18095A437)
- ML18095A439 + (ML18095A439)
- 05000272/LER-1990-023-01, :on 900725,discovered That Surveillance of Svc Water Sys Check Valves Not Completed Per Inservice Testing Program Manual Requirements.Caused by Inadequate Administrative Controls.Program Modified + (ML18095A440)
- 05000272/LER-1990-024-01, :on 900728,discovered That Interlock Functions for P-10 & P-12 Permissives Not Fully Tested Per Tech Spec Surveillance 4.3.1.1.2.Caused by Inadequate Administrative Controls.Procedures Revised to Address Testing + (ML18095A441)
- ML18095A442 + (ML18095A442)
- ML18095A443 + (ML18095A443)
- ML18095A444 + (ML18095A444)
- ML18095A445 + (ML18095A445)
- ML18095A447 + (ML18095A447)
- ML18095A448 + (ML18095A448)
- IR 05000272/1990021 + (ML18095A450)
- 05000272/LER-1990-025-01, :on 900806,control Room Air Intake Radiation Sys Monitor Alarm Circuitry Spiked High Resulting in Automatic Switching of Ventilation to Accident Mode of Operation.Addl Spikes Occurred on 900807 & 08 + (ML18095A452)
- ML18095A453 + (ML18095A453)
- ML18095A454 + (ML18095A454)
- ML18095A455 + (ML18095A455)
- 05000311/LER-1990-031, :on 900802,valve 21MS18 Main Steam Line Isolation Control Circuit Failed to Close.Caused by Failure to Wire Control Circuitry Per design.Seal-in Contacts Removed from Circuit & Circuit Adjusted + (ML18095A457)
- ML18095A458 + (ML18095A458)
- ML18095A459 + (ML18095A459)
- ML18095A460 + (ML18095A460)
- ML18095A461 + (ML18095A461)
- ML18095A462 + (ML18095A462)
- ML18095A463 + (ML18095A463)
- ML18095A464 + (ML18095A464)