Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18052B284 + (ML18052B284)
- ML18052B286 + (ML18052B286)
- ML18052B287 + (ML18052B287)
- ML18052B289 + (ML18052B289)
- ML18052B290 + (ML18052B290)
- ML18052B291 + (ML18052B291)
- ML18052B292 + (ML18052B292)
- ML18052B293 + (ML18052B293)
- ML18052B294 + (ML18052B294)
- ML18052B295 + (ML18052B295)
- ML18052B296 + (ML18052B296)
- ML18052B297 + (ML18052B297)
- ML18052B298 + (ML18052B298)
- ML18052B299 + (ML18052B299)
- ML18052B300 + (ML18052B300)
- ML18052B301 + (ML18052B301)
- ML18052B302 + (ML18052B302)
- ML18052B303 + (ML18052B303)
- ML18052B304 + (ML18052B304)
- ML18052B305 + (ML18052B305)
- 05000255/LER-1987-025, :on 870817,electro-hydraulic Control Sys Supply Line Failed.Caused by Rupture of Flexible Fluid Supply Hose to Governor Valve.Manual Reactor Trip Initiated.Flexible Hose Replaced W/Rigid Tubing + (ML18052B307)
- ML18052B308 + (ML18052B308)
- ML18052B309 + (ML18052B309)
- ML18052B310 + (ML18052B310)
- ML18052B311 + (ML18052B311)
- ML18052B312 + (ML18052B312)
- ML18052B314 + (ML18052B314)
- ML18052B315 + (ML18052B315)
- ML18052B316 + (ML18052B316)
- ML18052B323 + (ML18052B323)
- ML18052B326 + (ML18052B326)
- 05000255/LER-1987-026, :on 870821,audible Air Leakage Identified from Containment Into Airlock Through Closed Inner Airlock Door, in Violation of Tech Specs.Caused by Procedural Deficiency. Sealing Surface Adjusted Into Continuous Bead + (ML18052B329)
- 05000255/LER-1987-027, :on 870823,automatic Reactor Trip Occurred Due to Loss of Field in Main Generator.Caused by Failure of Main Generator Voltage Regulator Output.Failed Bias Supply Potentiometer Replaced & Tested + (ML18052B330)
- ML18052B331 + (ML18052B331)
- 05000255/LER-1987-028, :on 870825,primary Coolant Sys Temp Dropped Below 525 F.Caused by Starting of Main Feedwater Pump P-1B After Boron Addition to Primary Coolant Sys.Control Rods Withdrawn & Tech Spec Section 3.1.3c Changed + (ML18052B333)
- ML18052B334 + (ML18052B334)
- IR 05000255/1987022 + (ML18052B336)
- 05000255/LER-1987-029-02, :on 870901,auxiliary Feedwater Actuation Sys Inadvertently Actuated.Caused by Personnel Error.Tech Spec Surveillance Procedure MI-39 Being Reviewed to Determine If Required Actions Can Be More Clearly Defined + (ML18052B337)
- 05000255/LER-1987-030, :on 870903,QA Personnel Identified That Safety Injection tank,T-82B (Bp;Tk),Not Being Sampled for Boron Concentration at Frequency Specified in Facility Tech Specs. Tech Spec Change Request Submitted on 870911 + (ML18052B338)
- 05000255/LER-1987-031, :on 870903,diesel Generator Declared Inoperable.Caused by Slow Voltage Regulator Response. Adjustments Made to Diesel Generator Ref Voltage & Voltage Stability Feedback Circuit + (ML18052B341)
- NL-18-0188, License Amendment Request to Incorporate Seismic Probabilistic Risk Assessment Into the 10 CFR 50.69 Categorization Process, Response to Request for Additional Information (RAIs 4-11) + (ML18052B342)
- ML18052B343 + (ML18052B343)
- ML18052B344 + (ML18052B344)
- ML18052B345 + (ML18052B345)
- ML18052B346 + (ML18052B346)
- ML18052B347 + (ML18052B347)
- IR 05000255/1987019 + (ML18052B349)
- 05000255/LER-1987-033, :on 870903,high-range Noble Gas Stack Monitor Declared Inoperable When Detector Output Values Fell Below Tech Spec Requirements.Caused by Failure of Anode Insulator. Detector Will Be Refurbished by 871115 + (ML18052B350)
- 05000255/LER-1987-032, :on 870910,LPSI Pump P-67B Inadvertently Actuated During Preventive Maint to Contacts of DBA Sequencer.Caused by Personnel Slipping Screwdriver Off Head of Cam Screw.Cam & Sequencer Will Be Replaced + (ML18052B352)
- ML18052B353 + (ML18052B353)
- ML18052B354 + (ML18052B354)