- 05000220/LER-1980-023-03, /03L-0:on 800922,111 Absolute Filter Access Cover Was Found Off Housing.Caused by Residual Pressure in Containment Nitrogen Inerting Line Pressurizing Filter Housing When Torus Venting Initiated.Cover Reinstalled + (ML18037A295)
- 05000220/LER-1980-022-03, /03L-0:on 800927,low Power Range Monitor Detector Failed Rendering Average Power Range Monitor 18 Inoperable. Caused by Internal Shorting.Low Power Range Monitor Will Be Replaced During Next Refueling + (ML18037A296)
- 05000220/LER-1980-024-03, /03L-0:on 800930,during Audit,Discovered That Point Valve Was Not Recorded on 790721 Instrument Surveillance Test for Drywell High Pressure Trip Sys.Caused by Personnel oversight.Two-level Review Instituted + (ML18037A298)
- ML18037A299 + (ML18037A299)
- ML18037A301 + (ML18037A301)
- ML18037A302 + (ML18037A302)
- ML18037A304 + (ML18037A304)
- 05000220/LER-1980-018-03, /03L-0:on 800808,during Normal Operation, Emergency Diesel Generator 103 Fuel Oil Day Tank Low Level Alarm Was Received.Caused by Inadvertent Opening of Day Tank Drain Valve.Tank Refilled.Oil Valve Sys Locked + (ML18037A305)
- ML18037A306 + (ML18037A306)
- 05000220/LER-1980-026-01, /01T-0:on 801118,input Error Discovered Which Resulted in Reduction in Calculated Pressure Margin to Reactor Safety Valve Setpoints During Possible Transients + (ML18037A307)
- ML18037A308 + (ML18037A308)
- 05000220/LER-1980-025-03, /03L-0:on 801028,stack Gas Monitoring Sys Rendered Inoperable When Inadvertently Left in Purge Operation Mode for 9.5-h.Caused by Technician Failing to Return Sys to Normal Operation.Monitor Returned to Operation + (ML18037A309)
- ML18037A310 + (ML18037A310)
- ML18037A311 + (ML18037A311)
- 05000220/LER-1980-027-03, /03L-0:on 801126,operability Tests Were Not Immediately Performed as Required.Caused by Misunderstanding of Intent of Procedure.Testing Performed + (ML18037A312)
- 05000220/LER-1980-028-04, /04T-0:on 801215,results of 801103,26 & 1201 Milk Sample Tests Showed Detectable I-131 at Three Locations. Caused by Chinese Nuclear Weapons Test During Oct.Plant Not Accountable for Detected Levels + (ML18037A313)
- 05000220/LER-1980-031-01, /01T-0:on 801216,feedwater Flow Control Valve Pneumatic Positioner Unit II Vented Excessive Amount of Air. Caused by Cracked & Worn Rubber Goods.Rubber Goods Replaced & Retested + (ML18037A314)
- ML18037A315 + (ML18037A315)
- 05000220/LER-1980-030-04, /04T-0:on 801204,discovered That Lower Limit of Detection for Radiological Fish Analysis Was Not within Ets. Caused by Conversion Factor.Tech Spec Changes Proposed to Update Parameter + (ML18037A316)
- ML18037A317 + (ML18037A317)
- ML18037A318 + (ML18037A318)
- 05000220/LER-1980-034-03, /03L-0:on 801229,one Fuel Handling & One Instrument Surveillance Procedure Not Sorc Reviewed within 7-day Tech Spec Requirement.Caused by Oversight of Due Date. Review Performed + (ML18037A319)
- ML18037A320 + (ML18037A320)
- 05000220/LER-1980-033-03, /03L-0:on 801224,auxiliary Power Feed Experienced Loss to Emergency Power Bus.Caused by Feeder Breaker Trip Due to Setpoint on Over Frequency Protective Relay Being Set Too Close to Nominal Frequency.Relay Recalibr + (ML18037A321)
- 05000220/LER-1980-032-03, /03L-0:on 801216,one Filter Bank in Branch 11 of Emergency Ventilation Sys Found Leaking in Excess of Tech Spec.Caused by Defective Filter Sealing Gasket.New Filter Unit Installed + (ML18037A323)
- ML18037A324 + (ML18037A324)
- ML18037A325 + (ML18037A325)
- 05000220/LER-1981-001-03, /03L:on 810107,emergency Diesel Generator Output Breaker Tripped on Excessive Current.Caused by Failure of Generator Voltage Regulator Due to Protective Fuse Blow + (ML18037A326)
- 05000220/LER-1981-004-01, /01T-0:on 810209,main Steam Radiation Monitor 111 Signal Fluctuated,Causing Multiple Half Scrams.Caused by Loose detector-to-cable Connector.Connector Tightened + (ML18037A328)
- ML18037A330 + (ML18037A330)
- ML18037A331 + (ML18037A331)
- ML18037A333 + (ML18037A333)
- ML18037A335 + (ML18037A335)
- ML18037A336 + (ML18037A336)
- ML18037A337 + (ML18037A337)
- ML18037A338 + (ML18037A338)
- 05000220/LER-1981-002, Has Been Cancelled + (ML18037A341)
- 05000220/LER-1981-003, Has Been Cancelled + (ML18037A342)
- ML18037A343 + (ML18037A343)
- ML18037A348 + (ML18037A348)
- ML18037A349 + (ML18037A349)
- ML18037A350 + (ML18037A350)
- ML18037A351 + (ML18037A351)
- ML18037A354 + (ML18037A354)
- ML18037A355 + (ML18037A355)
- ML18037A357 + (ML18037A357)
- ML18037A358 + (ML18037A358)
- ML18037A359 + (ML18037A359)
- ML18037A360 + (ML18037A360)