- ML18037A184 + (ML18037A184)
- ML18037A186 + (ML18037A186)
- ML18037A187 + (ML18037A187)
- 05000220/LER-1979-018-03, /03L-0 on 790726:vacuum Relief Sys Switch 68-12B Failed to Open at Proper Setpoint.No Cause Identified.Switch Adjusted to Proper Setpoint + (ML18037A188)
- ML18037A192 + (ML18037A192)
- ML18037A193 + (ML18037A193)
- 05000220/LER-1979-021-04, /04T-0:on 790905,noted That Analysis of Excesssive Nuclide Water Sample Concentrations Was Not Completed within 30 Days.Caused by Late Rept by Contractor & High Influx of Samples.Addl Personnel Added + (ML18037A194)
- ML18037A195 + (ML18037A195)
- ML18037A196 + (ML18037A196)
- 05000220/LER-1979-019-03, /03L-0:on 790816,during Steady State Operation, Routine Mgt Review Disclosed Failure to Complete Five Surveillance Tests on Schedule.Tests Immediately Performed & Completed.Personnel Instructed to Follow Published Schedule + (ML18037A197)
- 05000220/LER-1979-020-03, /03L-0:on 790901,during Steady State Operation, Drywell Cooler 14 Tripped & Leakage Increased to Above Five G/Minute.Caused by Cooler Tube Leak.Cooler Isolated & Returned to Acceptable Level.Shutdown Terminated + (ML18037A198)
- ML18037A199 + (ML18037A199)
- ML18037A200 + (ML18037A200)
- ML18037A201 + (ML18037A201)
- 05000220/LER-1979-013-03, /03L-1:on 790525,during Refuelling Outage,Three Instrument Surveillance Procedures Were Implemented Before Required Temporary procedure-change Signatures Were Obtained.Cause Not Stated + (ML18037A203)
- 05000220/LER-1979-022-01, /01T-0:on 790918,noted Failure to Install Seismic Constraint on Containment Spray Sys Outside Primary Containment Per Const Drawings.Initiated Design & Order to Install Constraint.Containment Spray Loop Inoperable + (ML18037A204)
- ML18037A205 + (ML18037A205)
- ML18037A206 + (ML18037A206)
- 05000220/LER-1979-023-03, /03L-0:on 791004,cooling Water Pump of Diesel Generator 103 Tripped.Caused by Burned Contacts in Breaker. Breaker Repaired & Pump Started Manually.Preventative Maint Procedure Will Be Revised + (ML18037A207)
- ML18037A208 + (ML18037A208)
- 05000220/LER-1979-025-03, /03L-0:on 791027,during Surveillance Testing, Personnel Unable to Zero Side Average Power Range Monitor Flow Converter 11.Caused by Component Failure.Entire Unit Replaced & Problem Eliminated + (ML18037A209)
- ML18037A210 + (ML18037A210)
- ML18037A211 + (ML18037A211)
- ML18037A212 + (ML18037A212)
- ML18037A213 + (ML18037A213)
- ML18037A232 + (ML18037A232)
- 05000220/LER-1980-002-04, /04L-0:on 800109,during Steady State Operation, Review of Differential Recorder Revealed Condenser Inlet/ Screenwell Discharge Differential Temp Went Over Established Limits.Caused by Instrument Malfunction + (ML18037A233)
- ML18037A234 + (ML18037A234)
- 05000220/LER-1980-001-03, /03L-0:on 800102,during Steady State Operation, Calculations Determined Planar Linear Heat Generation Rate Exceeded Tech Specs.Cause Unknown.Power Decreased. Calculation Revealed Heating Generation Rate within Limits + (ML18037A235)
- 05000220/LER-1980-003-01, /01T-0:on 800109,lab Analysis Not Performed on Charcoal Filter Samples from Rx Bldg & Control Room Emergency Ventilation Sys Per Tech Specs.Caused by Change in Operating Cycle Length.Will Revise Surveillance Schedule + (ML18037A236)
- ML18037A238 + (ML18037A238)
- ML18037A239 + (ML18037A239)
- 05000220/LER-1980-005-01, /01X-0:on 800203,engineering Evaluation of GE SIL 299 Required That low-low Setpoint for Reactor Core Water Level Be Raised 20 Inches.Caused by Efforts to Precisely Measure Actual to Indicated Water Level Difference + (ML18037A240)
- 05000220/LER-1980-006-04, /04L-0:on 800123-24,condensor Inlet/Circulating Water Discharge Temp Exceeded Tech Spec Limit.Following Flow Reversal,Discharge Temp Exceeded Lake Ambient by More than Tech Spec Limit.Caused by Instrument Failure + (ML18037A241)
- 05000220/LER-1980-007-03, /03L-0:on 800303,while Shutdown for Maint,Attempts to Close Both Air Operated Outside Main Steam Isolation Valves Failed.Caused by Rust Buildup in Pilot Shuttle.New Instrument Air Sys Is Being Installed + (ML18037A243)
- 05000220/LER-1980-008-03, /03L-0:on 800315,during Steady State Operation, Alarm in Control Room Signaled Loss of Flow to Stack Gas Sampling Sys.Caused by Stack Sample Flow Inlet Valve Failing Closed,Due to Arcing Relay Contacts + (ML18037A245)
- ML18037A247 + (ML18037A247)
- ML18037A248 + (ML18037A248)
- ML18037A249 + (ML18037A249)
- ML18037A252 + (ML18037A252)
- ML18037A253 + (ML18037A253)
- ML18037A254 + (ML18037A254)
- ML18037A256 + (ML18037A256)
- ML18037A257 + (ML18037A257)
- ML18037A258 + (ML18037A258)
- ML18037A259 + (ML18037A259)
- ML18037A260 + (ML18037A260)
- ML18037A261 + (ML18037A261)
- 05000220/LER-1980-010-03, /03L-0:on 800528,while Performing Valve Checks, Operator Discovered Cardox Tank Pressure Below Tech Spec Limits.Caused by Delivery of Too Low Temp Carbon Dioxide by Supplier.Low Pressure Alarm Connected + (ML18037A262)
- 05000220/LER-1980-009-03, /03L-0:on 800521,during Steady State Operation, Attempts to Stroke 122 Containment Spray Isolation Valve Failed.Caused by Isolation Valve Solenoids Being Dirty. Revising Procedures to Require Periodic Maint for Valve + (ML18037A263)
- ML18037A264 + (ML18037A264)