- ML13330A741 + (ML13330A741)
- ML13330A742 + (ML13330A742)
- ML13330A744 + (ML13330A744)
- ML13330A745 + (ML13330A745)
- ML13330A746 + (ML13330A746)
- ML13330A747 + (ML13330A747)
- 05000206/LER-1979-011, Forwards LER 79-011/03L-0 + (ML13330A748)
- 05000206/LER-1979-011-03, /03L-0:on 790806,noted Loss of May 1979 Monthly Drinking Samples for Tri-Cities Municipal Water District. Caused by Personnel Error & Lack of Administrative Control. Procedures Revised & Personnel Informed of Changes + (ML13330A751)
- ML13330A752 + (ML13330A752)
- ML13330A754 + (ML13330A754)
- ML13330A756 + (ML13330A756)
- ML13330A757 + (ML13330A757)
- ML13330A758 + (ML13330A758)
- ML13330A759 + (ML13330A759)
- 05000206/LER-1979-013-01, /01T-0:on 790906,while Penetrant Testing Pipe Per IE Bulletin 79-17,six Cracks Up to 1 Inch Long Were Found in Heat Affected Zone of Welds in Suction Piping to Refueling Water Pumps.Probably Caused by Chloride Stress Corrosi + (ML13330A760)
- ML13330A761 + (ML13330A761)
- ML13330A762 + (ML13330A762)
- ML13330A763 + (ML13330A763)
- ML13330A764 + (ML13330A764)
- ML13330A765 + (ML13330A765)
- ML13330A766 + (ML13330A766)
- ML13330A767 + (ML13330A767)
- ML13330A768 + (ML13330A768)
- 05000206/LER-1979-014, Forwards LER 79-014/03L-0 + (ML13330A769)
- 05000206/LER-1979-014-03, /03L-0:on 790829,erratic Behavior of One of Two Subchannels of Sequencer 2 Was Observed.Caused by Failure of Voltage Regulating Transistor in Power Supply.Reactor Brought to Subcritical Condition & Power Supply Replaced + (ML13330A771)
- ML13330A772 + (ML13330A772)
- ML13330A773 + (ML13330A773)
- ML13330A774 + (ML13330A774)
- ML13330A775 + (ML13330A775)
- ML13330A776 + (ML13330A776)
- ML13330A777 + (ML13330A777)
- ML13330A778 + (ML13330A778)
- 05000206/LER-1979-015, Forwards LER 79-015/01T-0 + (ML13330A779)
- 05000206/LER-1979-015-01, /01T-0:on 790925,inadvertent short-term Breach of Containment Integrity Occurred While Performing Investigative Maint on Containment Personnel Air Lock.Caused by Failed Timing Cam Roller Die Due to Overtorquing + (ML13330A781)
- ML13330A782 + (ML13330A782)
- ML13330A783 + (ML13330A783)
- ML13330A784 + (ML13330A784)
- ML13330A785 + (ML13330A785)
- ML13330A786 + (ML13330A786)
- ML13330A787 + (ML13330A787)
- ML13330A788 + (ML13330A788)
- ML13330A790 + (ML13330A790)
- ML13330A791 + (ML13330A791)
- ML13330A792 + (ML13330A792)
- ML13330A796 + (ML13330A796)
- ML13330A797 + (ML13330A797)
- ML13330A798 + (ML13330A798)
- 05000206/LER-1979-017-01, /01T-1:on 791107,following Loss of Power to Several Electrical Sys & 4 Kv Room Fire alarm,480-volt Bus Supply Breaker 1 Automatically Tripped.Caused by Rodent Bridging Two Energized phases,short-circuiting Bus + (ML13330A801)
- 05000206/LER-1979-018, Forwards LER 79-018/01T-0 + (ML13330A802)
- 05000206/LER-1979-018-01, /01T-0:on 791109,support Discovered Missing on Liquid Radwaste Disposal Sys Piping Outside Containment. Caused by Failure to Install Support During Field Const. New Support Installed During 791110 Unrelated Outage + (ML13330A805)
- ML13330A806 + (ML13330A806)