Browse wiki
Jump to navigation
Jump to search
AR 01669062 + and AR 00 +
IWB-3410 +, IWC-3000 +, IWB-2500 +, IWB-3000 +, IWB-3132 +, IWB-3522 +, IWC-5220 +, IWC-1222 +, IWC-2500 +, IWB-3142 +, IWB-5222 +, IWC-3122 +, IWB-1220 +, IWC-1220 +, IWC-2430 +, IWB-2420 +, IWB-3612 +, IWB-2400 +, IWB-2430 +, IWC-2400 +, IWC-3132 +, IWB-3512 +, IWB-2411 +, IWC-2411 +, IWC-2420 +, IWC-1221 +, IWB-3100 +, IWB-241 +, IWC-241 +, IWC-3200 +...
ML15062A055 +
10 CFR 50.55a +, 10 CFR 50.2#v +, 10 CFR 50.55a#g +, 10 CFR 50.55a#g4 +, 10 CFR 50.55a#b +, 10 CFR 50.55a#a3ii +, 10 CFR 50.55a#b2 +, 10 CFR 50.55a#b2xiv +, 10 CFR 50.55a#b2ixB +, 10 CFR 50.55a#g4ii +, 10 CFR 50.55a#b2viii +, 10 CFR 50.55a#b2ix +, 10 CFR 50.55a#g6iiD +, 10 CFR 50.55a#b2xxiA +, 10 CFR 50.55a#g6iiE +, 10 CFR 50.55a#g6iiF +, 10 CFR 50.55a#b2xxB +, 10 CFR 50.55a#b2xix +, 10 CFR 50.55a#b2ii +, 10 CFR 50.55a#g4i +, 10 CFR 50.55a#b2x +, 10 CFR 50.55a#b2xviiiA +, 10 CFR 50.55a#b2xxii +, 10 CFR 50.55a#b2xxvii +, 10 CFR 50.55a#b2xxix +, 10 CFR 50.55a#3ii +, 10 CFR 50.55a#b2xxviii +, 10 CFR 50.55#a + and 10 CFR 50.55#a3ii +
L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2014-105, Inservice Inspection Plan - Fifth Inspection Interval, Unit 3 Relief Request No. 1 - Response to Follow-up Request for Additional Information +, L-2014-100, Inservice Inspection Plan - Fifth Inspection Interval Unit 3 Relief Request No. 1 - Response to Request for Additional Information +, L-2014-096, Inservice Inspection Plan - Fifth Inspection Interval Unit 3 Relief Request No. 1 +, PM 043358 + and PM 048453 +
05000313/LER-2002-003, For Arkansas Unit 1 Reactor Coolant System Pressure Boundary Leakage from a Crack in a Control Rod Drive Mechanism Nozzle Reactor Vessel Head Penetration Weld Due to Previous Weld Repair Method +, ML14106A050 +, Regulatory Guide 1.161 +, ML14122A268 +, ML050700431 +, ML11132A183 +, ML14120A152 +, ML050700433 +, ML041540237 +, L-2014-105, Inservice Inspection Plan - Fifth Inspection Interval, Unit 3 Relief Request No. 1 - Response to Follow-up Request for Additional Information +, L-2014-100, Inservice Inspection Plan - Fifth Inspection Interval Unit 3 Relief Request No. 1 - Response to Request for Additional Information +, ML14099A191 +, L-2014-096, Inservice Inspection Plan - Fifth Inspection Interval Unit 3 Relief Request No. 1 +, ML13141A595 +, ML011350195 +, ML010090434 +, ML13360526 +, ML012320135 + and 05000338/LER-2003-001, From North Anna, Unit 1 Regarding Reactor Vessel Head Penetration Nozzle Leakage +
November 22, 1999 +
68 FR 60422 + and 68 FR 37590 +
NextEra Energy + and Kiley M +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan + and L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +
March 11, 2015 +
L-2015-040, Submittal of Fifth 10 Year Interval Inservice Inspection (ISI) Program Plan +, L-2014-105, Inservice Inspection Plan - Fifth Inspection Interval, Unit 3 Relief Request No. 1 - Response to Follow-up Request for Additional Information +, L-2014-100, Inservice Inspection Plan - Fifth Inspection Interval Unit 3 Relief Request No. 1 - Response to Request for Additional Information + and L-2014-096, Inservice Inspection Plan - Fifth Inspection Interval Unit 3 Relief Request No. 1 +
L-2014-071, Response to Request for Additional Information License Amendment Request No. 216 - Transition 10 CFR 50.48(c)-NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Generating Plants(2001 Edition) +, L-2014-105, Inservice Inspection Plan - Fifth Inspection Interval, Unit 3 Relief Request No. 1 - Response to Follow-up Request for Additional Information +, L-2014-033, License Amendment Request LAR-229, Application for Technical Specification Change Regarding Risk-Informed Justifications for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program + and ML17128A275 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
19:04:41, 10 January 2025 +
NEI 04-05 +, NEI 97-06, Steam Generator Conditioning Monitoring Report + and NEI 03-08, Notification of Deviation from Electric Power Research Institute (EPRI) Materials Reliability Program (MRP) 2019-008, Materials Reliability Program: Interim Guidance for NEI 03-08 Needed Requirements for Us PWR Plants . +
147 +
11 +
Request +
March 11, 2015 +
Washington + and Florida +
Boric Acid +, Non-Destructive Examination +, Weld Overlay +, Operating Basis Earthquake +, Nondestructive Examination +, VT-2 +, Incorporated by reference +, Aging Management +, Stress corrosion cracking +, Eddy Current Testing +, License Renewal +, Liquid penetrant +, Dissimilar Metal Weld +, Operability Assessment +, Power Uprate +, Thermal fatigue + and Water hammer +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.