RS-24-001, Response to Request for Additional Information Regarding Relief Request I5R-26, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval | 3 January 2024 | Response to Request for Additional Information Regarding Relief Request I5R-26, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval | VT-2 |
RS-23-128, Response to Request for Additional Information for the Emergency License Amendment Request Increase Technical Specifications Completion Time in TS 3.8.1.B.4 from 7 Days to 30 Days | 15 December 2023 | Response to Request for Additional Information for the Emergency License Amendment Request Increase Technical Specifications Completion Time in TS 3.8.1.B.4 from 7 Days to 30 Days | High winds Mission time Tornado Missile B.5.b Surveillance Frequency Control Program Recently irradiated fuel Offsite Circuit |
RS-23-068, Response to Request for Additional Information for Quad Cities Relief Request I6R-11, Proposed Alternatives for a Temper Bead Weld Repair of the Mating Surfaces of the Reactor Pressure Vessel Head and Shell | 28 April 2023 | Response to Request for Additional Information for Quad Cities Relief Request I6R-11, Proposed Alternatives for a Temper Bead Weld Repair of the Mating Surfaces of the Reactor Pressure Vessel Head and Shell | Nondestructive Examination |
RS-23-005, Response to Request for Additional Information for Quad Cities Relief Request RV-04, Inservice Testing of High Pressure Coolant Injection Drain Pot Solenoid Valves | 17 January 2023 | Response to Request for Additional Information for Quad Cities Relief Request RV-04, Inservice Testing of High Pressure Coolant Injection Drain Pot Solenoid Valves | |
ML23012A083 | 12 January 2023 | Response to Request for Additional Information for Alternative I6R-09 to Permit Continued Application of Certain ASME Section XI 2013 Edition Non-Destructive Examination Requirements | Non-Destructive Examination Nondestructive Examination VT-2 Liquid penetrant Dissimilar Metal Weld |
RS-22-109, Response to Request for Additional Information License Amendments Related to Fuel Storage | 12 October 2022 | Response to Request for Additional Information License Amendments Related to Fuel Storage | |
RS-22-108, Response to Request for Additional Information LaSalle County Station, Units 1 and 2 and Quad Cities Nuclear Power Station, Units 1 and 2 License Amendments Related to Fuel Storage | 5 October 2022 | Response to Request for Additional Information LaSalle County Station, Units 1 and 2 and Quad Cities Nuclear Power Station, Units 1 and 2 License Amendments Related to Fuel Storage | |
RS-22-095, Response to Request for Additional Information Regarding Request to Expand Applicability of GNF Thermal Mechanical Analysis Methods to Framatome Fuel | 10 August 2022 | Response to Request for Additional Information Regarding Request to Expand Applicability of GNF Thermal Mechanical Analysis Methods to Framatome Fuel | Fuel cladding |
RS-22-096, Response to Request for Additional Information Related to Relief Request I6R-01 Associated with the Sixth Inservice Inspection Interval | 10 August 2022 | Response to Request for Additional Information Related to Relief Request I6R-01 Associated with the Sixth Inservice Inspection Interval | VT-2 |
RS-22-098, Response to Request for Additional Information for Quad Cities Relief Request RV-11, Code Case OMN-28 | 1 August 2022 | Response to Request for Additional Information for Quad Cities Relief Request RV-11, Code Case OMN-28 | Scram Discharge Volume |
RS-22-090, Response to Request for Additional Information Regarding Quad Cities New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies | 13 July 2022 | Response to Request for Additional Information Regarding Quad Cities New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies | Earthquake Fire Protection Program |
RS-22-078, Response to Request for Additional Information for Quad Cities Relief Request RV-09, MSSVs | 30 June 2022 | Response to Request for Additional Information for Quad Cities Relief Request RV-09, MSSVs | Grace period |
RS-22-077, Response to Request for Additional Information for Quad Cities Relief Requests RV-08, Safety Relief Valves | 30 June 2022 | Response to Request for Additional Information for Quad Cities Relief Requests RV-08, Safety Relief Valves | |
RS-22-040, Response to Request for Additional Information Related to the License Amendment Request to Transition to GNF3 Fuel | 11 April 2022 | Response to Request for Additional Information Related to the License Amendment Request to Transition to GNF3 Fuel | Anticipated operational occurrence Post Accident Monitoring Fuel cladding |
RS-22-027, Constellation, Response to Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated | 23 February 2022 | Constellation, Response to Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-541 Revision 2, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated P | Surveillance Frequency Control Program |
NMP1L3447, Constellation Energy Generation, LLC - Response to Request for Additional Information - Proposed Relief Request Associated with Reactor Pressure Vessel Water Level Instrumentation Partial Penetration Nozzle Repairs | 2 February 2022 | Constellation Energy Generation, LLC - Response to Request for Additional Information - Proposed Relief Request Associated with Reactor Pressure Vessel Water Level Instrumentation Partial Penetration Nozzle Repairs | Nondestructive Examination VT-2 Foreign Material Exclusion Through-Wall Leakage |
RS-22-005, Response to Request for Additional Information for the GNF3 Fuel Transition License Amendment Request | 11 January 2022 | Response to Request for Additional Information for the GNF3 Fuel Transition License Amendment Request | Anticipated operational occurrence |
RS-21-113, Response to Supplemental Request for Information Related to Request for Licensing Amendment Regarding Transition to GNF3 Fuel | 3 November 2021 | Response to Supplemental Request for Information Related to Request for Licensing Amendment Regarding Transition to GNF3 Fuel | Post Accident Monitoring |
JAFP-21-0087, Response to Request for Additional Information Regarding Request for Approval of Transfer of Licenses and Conforming Amendments | 16 September 2021 | Response to Request for Additional Information Regarding Request for Approval of Transfer of Licenses and Conforming Amendments | |
RS-21-078, Response to Request for Additional Information for Application to Revise Technical Specification to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements, and TSTF-583-T, TSTF-582 Diesel | 19 August 2021 | Response to Request for Additional Information for Application to Revise Technical Specification to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements, and TSTF-583-T, TSTF-582 Diesel | Water Inventory Control Recently irradiated fuel Offsite Circuit |
JAFP-21-0044, Response to Request for Additional Information Regarding Request for Approval of Transfer of Licenses and Conforming Amendments | 11 June 2021 | Response to Request for Additional Information Regarding Request for Approval of Transfer of Licenses and Conforming Amendments | |
JAFP-21-0032, Response to Request for Additional Information - Proposed Alternative Concerning ASME Section XI Repair/Replacement Documentation for Replacement of Pressure Retaining Bolting | 20 April 2021 | Response to Request for Additional Information - Proposed Alternative Concerning ASME Section XI Repair/Replacement Documentation for Replacement of Pressure Retaining Bolting | |
RS-20-112, Response to Request for Additional Information Related to License Amendment Request to Adopt TSTF-568 | 3 September 2020 | Response to Request for Additional Information Related to License Amendment Request to Adopt TSTF-568 | |
RS-20-008, Response to Request for Additional Information for the License Amendment Request to Change Technical Specifications to Increase Allowable MSIV Leakage Rates and Revise Secondary Containment. | 24 February 2020 | Response to Request for Additional Information for the License Amendment Request to Change Technical Specifications to Increase Allowable MSIV Leakage Rates and Revise Secondary Containment. | |
JAFP-19-0057, Response to Request for Additional Information - Proposed Alternative to Utilize Code Cases N-878 and N-880 | 4 June 2019 | Response to Request for Additional Information - Proposed Alternative to Utilize Code Cases N-878 and N-880 | |
NMP1L3279, Response to Request for Additional Information - Proposed Alternatives to Utilize Code Cases N-878 and N-880 for Plants | 1 May 2019 | Response to Request for Additional Information - Proposed Alternatives to Utilize Code Cases N-878 and N-880 for Plants | |
JAFP-19-0006, Response to Request for Additional Information - Proposed Alternative to Utilize Code Cases N-878 and N-880 | 8 January 2019 | Response to Request for Additional Information - Proposed Alternative to Utilize Code Cases N-878 and N-880 | Commercial Grade Dedication Nondestructive Examination |
RS-18-143, Supplemental Information Supporting License Amendment Requests for Approval of Changes to Emergency Plan Staffing Requirements | 29 November 2018 | Supplemental Information Supporting License Amendment Requests for Approval of Changes to Emergency Plan Staffing Requirements | Safe Shutdown Fitness for Duty Health Physics Network Nuclear Accident Reporting System Severe Accident Management Guideline Minimum staff |
RS-18-097, Response to Request for Additional Information and Supplemental Information-License Amendment. | 27 July 2018 | Response to Request for Additional Information and Supplemental Information-License Amendment. | Minimum staff |
RS-18-061, Response to Request for Additional Information Regarding Decommissioning Funding Plans for Independent Spent Fuel Storage Installations (Isfsis) | 2 May 2018 | Response to Request for Additional Information Regarding Decommissioning Funding Plans for Independent Spent Fuel Storage Installations (Isfsis) | Decommissioning Funding Plan Authorized possession limits |
RS-18-004, Additional Information Supporting Reactor Pressure Vessel Penetration N-11B Repair Relief Request I5R-11 | 4 January 2018 | Additional Information Supporting Reactor Pressure Vessel Penetration N-11B Repair Relief Request I5R-11 | Nondestructive Examination Dissimilar Metal Weld |
RS-17-130, Additional Information Regarding Request for License Amendment to Revise Technical Specifications Section 5.5.12 for Permanent Extension of Type a and Type C Leak Rate Test Frequencies | 28 September 2017 | Additional Information Regarding Request for License Amendment to Revise Technical Specifications Section 5.5.12 for Permanent Extension of Type a and Type C Leak Rate Test Frequencies | Probabilistic Risk Assessment FLEX Large early release frequency |
RS-17-111, Additional Information Regarding Request for License Amendment to Revise Technical Specifications Section 5.5.12 for Permanent Extension of Type a and Type C Leak Rate Test Frequencies | 27 July 2017 | Additional Information Regarding Request for License Amendment to Revise Technical Specifications Section 5.5.12 for Permanent Extension of Type a and Type C Leak Rate Test Frequencies | Safe Shutdown High winds Ultimate heat sink Tornado Missile Internal Flooding Probabilistic Risk Assessment Functionality Assessment FLEX Large early release frequency Moisture barrier Hardened vent |
RS-17-041, Response to Request for Additional Information Regarding Request for License Amendment to Revise Loss of Voltage Relay Settings | 24 April 2017 | Response to Request for Additional Information Regarding Request for License Amendment to Revise Loss of Voltage Relay Settings | Safe Shutdown Anticipated operational occurrence |
RS-17-044, Response to Request for Additional Information Regarding Proposed Alternative for the Use of Encoded Phased Array Ultrasonic Examination Techniques in Lieu of Radiography | 13 March 2017 | Response to Request for Additional Information Regarding Proposed Alternative for the Use of Encoded Phased Array Ultrasonic Examination Techniques in Lieu of Radiography | Hydrostatic Nondestructive Examination Incorporated by reference Dissimilar Metal Weld |
RS-16-254, Supplemental Information Regarding Request for License Amendment to Revise Technical Specifications Section 5.5.12 for Permanent Extension of Type a and Type C Leak Rate Test Frequencies | 15 December 2016 | Supplemental Information Regarding Request for License Amendment to Revise Technical Specifications Section 5.5.12 for Permanent Extension of Type a and Type C Leak Rate Test Frequencies | Mission time Internal Flooding Probabilistic Risk Assessment Maintenance Rule Program |
RS-16-244, Additional Information Regarding Request for License Amendment to Address Secondary Containment Access Openings | 12 December 2016 | Additional Information Regarding Request for License Amendment to Address Secondary Containment Access Openings | |
RS-16-229, Supplemental Information Regarding Request for License Amendment to Revise Loss of Voltage Relay Settings | 21 November 2016 | Supplemental Information Regarding Request for License Amendment to Revise Loss of Voltage Relay Settings | Grace period |
RS-16-159, County, and Quad Cities - Response to Request for Additional Information Regarding License Amendment to Address Secondary Containment Access Openings | 28 July 2016 | County, and Quad Cities - Response to Request for Additional Information Regarding License Amendment to Address Secondary Containment Access Openings | Maintenance Rule Program |
RS-16-131, Additional Information Regarding License Amendment Request for Spent Fuel Storage Pool Criticality Methodology for Fuel Channel Bow/Bulge | 1 June 2016 | Additional Information Regarding License Amendment Request for Spent Fuel Storage Pool Criticality Methodology for Fuel Channel Bow/Bulge | |
RA-16-049, Response to Request for Additional Information Regarding Requests to Withhold Emergency Preparedness Documents from Public Disclosure | 26 May 2016 | Response to Request for Additional Information Regarding Requests to Withhold Emergency Preparedness Documents from Public Disclosure | Safe Shutdown High winds Loop seal Ultimate heat sink Enforcement Discretion Probabilistic Risk Assessment Operating Basis Earthquake FLEX Design basis earthquake Severe Accident Management Guideline B.5.b Mitigating Strategies Earthquake Fire Watch Downpower |
RS-16-105, Supplemental Information in Support of Request for License Amendment Regarding Transition to Areva Fuel | 26 April 2016 | Supplemental Information in Support of Request for License Amendment Regarding Transition to Areva Fuel | |
RS-16-077, Response to Request for Additional Information Regarding Request for License Amendment to Reduce the Reactor Steam Dome Pressure Specified in the Technical Specification 2.1.1, Reactor Core Sls. | 14 April 2016 | Response to Request for Additional Information Regarding Request for License Amendment to Reduce the Reactor Steam Dome Pressure Specified in the Technical Specification 2.1.1, Reactor Core Sls. | Reactor Vessel Water Level Anticipated operational occurrence Fuel cladding |
RS-16-044, High Frequency Supplement to Seismic Hazard Screening Report, Response to NRC Request for Information, Per 10CFR50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima.. | 19 February 2016 | High Frequency Supplement to Seismic Hazard Screening Report, Response to NRC Request for Information, Per 10CFR50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima.. | Safe Shutdown Earthquake Probabilistic Risk Assessment Fukushima Dai-Ichi Earthquake |
RS-16-018, Response to Request for Additional Information Regarding Request for License Amendment Regarding Transition to Areva Fuel | 28 January 2016 | Response to Request for Additional Information Regarding Request for License Amendment Regarding Transition to Areva Fuel | Safe Shutdown Shutdown Margin Anticipated operational occurrence Feedwater Controller Failure Earthquake |
RS-15-274, Supplemental Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Flooding Aspects of Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident | 28 October 2015 | Supplemental Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Regarding the Flooding Aspects of Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accident | Fukushima Dai-Ichi |
RS-15-258, County, and Quad Cities - Response to Request for Additional Information Regarding License Amendment Request Adding Technical Specification for Inservice Leak and Hydrostatic Testing Operation | 29 September 2015 | County, and Quad Cities - Response to Request for Additional Information Regarding License Amendment Request Adding Technical Specification for Inservice Leak and Hydrostatic Testing Operation | Reactor Vessel Water Level Hydrostatic |
RS-12-149, Response to Request for Additional Information Regarding Relief Requests Associated with the Fifth Inservice Testing Interval | 13 September 2012 | Response to Request for Additional Information Regarding Relief Requests Associated with the Fifth Inservice Testing Interval | Stroke time Grace period |
ML17238A751 | 31 August 1973 | Quad-Cities Stations Units 1 and 2 - 10 CFR 50, Appendix J | |