Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML20217K97614 October 1999Amend 234 to License DPR-56,changing TS in Response to 990301 Application & Suppls ,1001 & 06,to Support PBAPS Mod P00507,which Will Install Digital Pr Neutron Monitoring SysShutdown Margin
High Radiation Area
Abnormal operational transient
Scram Discharge Volume
Fuel cladding
Power change
Coast down
ML20217B4265 October 1999Amend 233 to License DPR-56,changing Minimum Critical Power Ratio Safety Limit & Approved Methodologies Referenced in Core Operating Limits ReptsReactor Vessel Water Level
ML20216H68924 September 1999Amends 229 & 232 to Licenses DPR-44 & DPR-56,respectively, Delete SR Associated Only with Refueling Platform Fuel Grapple Fully Retracted Position Interlock Input,Currently Required by TSs SR 3.9.1.1
ML20211D54723 August 1999Amends 228 & 231 to Licenses DPR-44 & DPR-56,respectively, Revising TSs to Correct Typo & Editorial Errors Introduced in TSs by Previous Amends
ML20205K7377 April 1999Amends 227 & 230 to Licenses DPR-44 & DPR-56,respectively, Consisting of Changes to TS SRs Re Secondary Containment Doors in Response to 980204 Application,As Revised by
ML20155C60126 October 1998Amend 226 to License DPR-44,revising TSs for Safety Limit MCPR from Current Value of 1.11 to 1.10 for Two Recirculation Loop Operation & from 1.13 to 1.12 for Single Recirculation Loop OperationReactor Vessel Water Level
ML20154J2265 October 1998Amends 224 & 228 to Licenses DPR-44 & DPR-56,respectively, Revising TSs to Delete Requirements for Functional Testing of SRVs During Each Unit Startup
ML20154H4695 October 1998Amends 225 & 229 to Licenses DPR-44 & DPR-56,respectively, Revising TSs to Permit Incorporation of EOC-RPT Sys at Plant,Units 2 & 3Shutdown Margin
Post Accident Monitoring
Scram Discharge Volume
Pressure Boundary Leakage
Coast down
ML20154G6551 October 1998Amends 223 & 227 to Licenses DPR-44 & DPR-56,respectively, Revising Plant,Units 2 & 3 TSs to Exclude MSIV Leakage from Total Type B & Type C Local Leak Rate Test Results
ML20153B95814 September 1998Amend 9 to License DPR-12,adding Requirements for Control of Effluents & Annual Reporting Per 10CFR50.36a
ML20238F26124 August 1998Amend 222 to License DPR-44,revising Pbaps,Unit 2 TSs to Support Mod P00271,which Would Replace SRMs & IRMs W/Wrnms, During Forthcoming Outage 2R12,scheduled for Early Oct 1998Shutdown Margin
High Radiation Area
Post Accident Monitoring
Scram Discharge Volume
Fuel cladding
Power change
Coast down
ML20212G82624 October 1997Amends 221 & 226 to Licenses DPR-44 & DPR-56,respectively, Changing TSs to Eliminate Inconsistency Between ECCS Operability Requirements & Autostart & Protective Trip Bypass of EDGs on ECCS Initiation SignalOffsite Circuit
ML20217J5579 October 1997Amend 225 to License DPR-56,revising MCPR Safety Limit in Section 2.1 of TSs from 1.07 to 1.11 for Two Recirculation Loops in OperationReactor Vessel Water Level
ML20217D81030 September 1997Amend 224 to License DPR-56,revises TS to Support PBAPS Mod P00271,which Would Replace Source Range & Intermediate Range Monitors W/Wide Range Neutron Monitoring SystemShutdown Margin
Post Accident Monitoring
Scram Discharge Volume
Fuel cladding
Power change
Coast down
ML20216G5324 September 1997Amends 220 & 223 to Licenses DPR-44 & DPR-56,respectively, Revising TS to Extend Replacement Frequency for Inflatable Seat Seals for Primary Containment Purge & Vent Valves to 96 Months
ML20217M79619 August 1997Amends 219 & 222 to Licenses DPR-44 & DPR-56,respectively, Extending APRM Flow Bias Instrumentation Surveillance Interval from 18 Months to 24 MonthsScram Discharge Volume
ML20135B38519 February 1997Amends 218 & 221 to Licenses DPR-44 & DPR-56,respectively, Changing Min Allowable Charging Water Header Pressure from Value 955 Psig to Value of 940 Psig in TS 3.10.8Shutdown Margin
ML20062C04016 October 1978Amend 48 to License DPR-44,revising Tech Specs to Permit Plant Operation W/New 8x8R Reload Fuel for Cycle 4Shutdown Margin
Hydrostatic
Abnormal operational transient
Scram Discharge Volume
Fast acting solenoid valve
Overtravel
Fuel cladding
ML20062B05510 October 1978Amend 47 to License DPR-56,changing Tech Specs Re Fire Protection & Administrative ControlsShutdown Margin
High Radiation Area
Fire Barrier
ML20062B05210 October 1978Amend 47 to License DPR-44,changing Tech Specs Re Instrumentation That Initiates or Controls Core & Containment Cooling Sys,Administrative Controls & safety-related SnubbersShutdown Margin
High Radiation Area
Fire Barrier
ML20062B8623 October 1978Amend 46 to License DPR56,changing Tech Specs Re Surveillance of Suppression Pool Temp Logging,Controlled Bypass Heatup Line on HPCI Steam Supply & Identification of Valves to Reflect Plant Unique Designation
ML20062B8483 October 1978Amend 46 to License DPR-44,changing Tech Specs Re Surveillance of Suppression Pool Temp Logging,Controlled Bypass Heatup Line on HPCI Steam Supply & Identification of Valves to Reflect Plant Unique Designation
ML20210Q33925 October 1973Amend 1 to License DPR-44 & Amend to License DPR-56, Reflecting Change in Corporate Structure at Pse&GSafe Shutdown
Fire Protection Program