Text
..
ep+1 *ouq g
UNITED STATES NUCLEAR REGULATORY COMMISSION f
WASHINGTON, D.C. 2006M201 3 * * * *
- y/
d PECO ENERGY COMPANY PUBLIC SERVICE ELECTRIC AND GAS COMPANY DELMARVA POWER AND LIGHT COMPANY i
ATLANTIC CITY ELECTRIC COMPANY 4
DOCKET NO. 50-277 i
PEACH BOTTOM ATOMIC POWER STATION. UNIT NO. 2 1
AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 218 License No. DPR-44 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by PECO Energy Company, et al. (the licensee) dated August 27, 1996, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (th'.
Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I.
4 B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C(2) of Facility Operating License No. DPR-44 is hereby amended to read as follows:
9703030030 970219 PDR ADOCK 05000277 P
1 (2) Technical Soecifications The Technical Specifications contained in Appendices A and B, as revised through Amendwnt No. 218, are hereby incorporated in the license.
PECO Energy Company shall operate the facility in accordance with the Technical Specifications.
l 3.
This license amendment is effective es of its date of issuance and is to be implemented within 30 days.
FOR THE N'JCLEAR REGULATORY COMMISSION (L
f Johp F.' Stolz, Director /
Pr4 Ject Directorate I-2 Division of Reactor Drojects - I/II Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: February 19, 1997 i
i s
ATTACHMENT TO LICENSE AMENDMENT NO. 218 4
\\
i FACILITY OPERATING LICENSE NO. DPR-44 DOCKET NO. 50-277 4
Replace the following page of the Appendix A Technical Specifications with the j
enclosed page. The revised areas are indicated by marginal lines.
i Remove Insert 3.10-20 3.10-20 j
i i
l l
1 4
. ~.. _. -. _... _.. _
'l l.
SON Test-Refueling 3.10.8 l
3.10 SPECIAL OPERATIONS 3.10.8 SHUTDOWN MARGIN (SDM) Test-Refueling LC0 3.10.8 The reactor mode switch position specified in Table 1.1-1 for MODE 5 may be changed to include the startup/ hot standby position, and operation considered not to be in MODE 2, to allow SOM testing, provided the following requirements are l
met:
a.
LCO 3.3.1.1, " Reactor Protection System Instrumentation," MODE 2 requirements for Functions 2.a and 2.e of Table 3.3.1.1-1; b.
1.
LCO 3.3.2.1, " Control Rod Block Instrumentation,"
MODE 2 requirements for Function 2 of Table 3.3.2.1-1, with the banked position withdrawal sequence requirements of SR 3.3.2.1.8 changed to require the control rod sequence to conform to the SDM test sequence, DE 2.
Conformance to the approved control rod sequence for the SDM test is verified by a second licensed operator or other qualified member of the technical staff; c.
Each withdrawn control rod shall be coupled to the associated CRD; d.
All control rod withdrawals during out of sequence control rod moves shall be made in notch out mode; e.
No other CORE ALTERATIONS are in progress; and l
f.
CRD charging water header pressure a 940 psig.
4 APPLICABILITY:
MODE 5 with the reactor mode switch in startup/ hot standby position.
i f
l l
PBAPS UNIT 2 3.10-20 Amendment No, ett( 218 t
y-,, t UNITED STATES p
}
NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20666-0001
\\..... p/
i PECO ENERGY COMPANY PUBLIC SERVICE ELECTRIC AND GAS COMPANY DELMARVA POWER AND LIGHT COMPANY ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-278 l
i PEACH BOTTOM ATOMIC POWER STATION. UNIT NO. 3 4
i AMENDMENT TO FACILITY OPERATING LICENSE i
Amendment No. 221 i
License No. DPR-56 4
1.
The Nuclear Regulatory Commission (the Comission) has found that:
A.
The application for amendment by PECO Energy Company, et i
al. (the licensee) dated August 27, 1996, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I.
B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission;-
C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health or safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied..
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C(2) of Facility Operating License No. OPR-56 is hereby amended to read as follows:
. (2) Technict1 Soecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.221, are hereby incorporated in the liceriss.
PECO shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of its date of issuance and is to be implemented within 30 days.
FOR THE NUCLEAR REGULATORY COMMISSION L
40 n F. Stolz, Directo e oject Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: February 19, 1997 l
4
_. ~.
i i
l ATTACHMENT TO LICENSE AMENDMENT NO. 221 j
FACILITY OPERATING LICENSE NO. OPR-56 DOCKET NO. 50-278 i
Replace the fnllowing page of the Appendix A Technical Specifications with the j
enclosed page. The revised areas are indicated by marginal lines.
8 l
Remove Insert 3.10-20 3.10-20 1
SDM Test-Refueling 3.10.8 3.10 SPECIAL OPERATIONS 3.10.8 SHUTDOWN MARGIN (SDM) Test-Refueling LCO 3.10.8 The reactor mode switch position specified in Table 1.1-1 for MODE 5 may be changed to include the startup/ hot standby position, and operation considered not to be in MODE 2, to allow SDM testing, provided the following requirements are met:
l a.
LCO 3.3.1.1, " Reactor Protection System i
Instrumentation," MODE 2 requirements for Functions 2.a i
and 2.e of Table 3.3.1.1-1; b.
1.
LCO 3.3.2.1, " Control Rod Block Instrumentation,"
MODE 2 requirements for Function 2 of Table 3.3.2.1-1, with the banked position withdrawal i
sequence requirements of SR 3.3.2.1.8 changed to require the control rod sequence to conform to the SDM test sequence, E
i 2.
Conformance to the approved control rod sequence for the SDM test is verified by a second licensed operator or other qualified member of the technical i
staff; l
c.
Each withdrawn control rod shall be coupled to the associated CRD; d.
All control rod withdrawals during out of sequence control rod moves shall be made in notch out mode; e.
No other CORE ALTERATIONS are in progress; and l
f.
CRD charging water header pressure a 940 psig.
l APPLICABILITY:
MODE 5 with the reactor mode switch in startup/ hot standby l
position.
l l
PBAPS UNIT 3 3.10-20 Amendment No.X, 221