Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML23066A221 | 7 March 2023 | Velan, Inc. - Revised Part 21 Notification Re Butterfly Valves Found to Have a Number of Fasteners Loose | |
ML21225A081 | 4 August 2021 | Lake Engineering Co., Final Report Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 | |
ML20136A255 | 21 April 2020 | 10 CFR Part 21 Report Notification for Curtiss Wright Scientech Certain RTL500 and RTL851 Modules | |
ML19261A194 | 6 September 2019 | Final Report (Log # 2019-22-00) (Event# EN 54215) - Non-Destructive Examination (Liquid Penetrant) Performance of Components by an Un-Qualified Employee | Non-Destructive Examination Liquid penetrant |
ML19071A112 | 1 March 2019 | Lake Engineering Co., Corrected Potentially Degraded Snubber SF1154 Hydraulic Fluid Batch 11KLVS146 Final Report, Per 10 CFR Part 21 | |
ML17194A825 | 11 July 2017 | Part 21 Report Re Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valves with Threaded Stem to Upper Wedge Connections | Anchor Darling |
ML17081A453 | 20 March 2017 | Part 21 - Plastic Jar Dedication Sampling | |
ML17026A414 | 20 January 2017 | C&D Technologies, Inc. - Part 21 - Plastic Jar Dedication Sampling | |
ML16321A451 | 21 October 2016 | Part 21 Reporting of Defects and Noncompliance | Commercial Grade |
ML16251A098 | 2 September 2016 | Part 21 - Potential Failure of Battery System Connections | |
ML16243A472 | 25 August 2016 | Part 21 Reporting of Defects and Noncompliance | Commercial Grade |
ML16139A834 | 10 May 2016 | Electroswitch - Transmittal of 10CFR Part 21 Reporting of Defects and Noncompliance Regarding Vendor Inspection of Electroswitch Corporation Docket No. 99900833 | Commercial Grade |
ML16076A261 | 11 March 2016 | Part 21 - Commercial Grade Cap Screws Provided with Safety Related Fisher Type 3570 Positioners | Commercial Grade |
ML15205A289 | 24 July 2015 | Notification of Part 21 Report - Deviation in Nozzle Modeling Internal Reports | |
ML15188A066 | 25 June 2015 | Part 21 Report - Deviation in Nozzle Modeling Internal Reports | |
ML15155A575 | 29 May 2015 | C&D Technologies, Inc. - Interim Report - Inability to Complete 10CFR Part 21 Evaluation Regarding Cracking in KCR-13 Standby Battery Jars at Indian Point | |
ML15155A576 | 29 May 2015 | C&D Technologies, Inc., Interim Part 21 Report - Inability to Complete Evaluation Regarding Cracking in KCR-13 Standby Battery Jars at Indian Point | |
ML15103A485 | 7 April 2015 | Itt Engineered Valves - 2nd Interim Report to the NRC of 10 CFR 21 Event 50285, Reported by Itt 07/18/14 Concerning M I Diaphragms, Customer Testing | |
ML15089A437 | 20 March 2015 | Part 21 - Dual Alarm Modules That May Contain Faulty Diodes in Single State Relays | Exclusive Use |
ML14274A052 | 22 September 2014 | Final Report 10CFR Part 21 Evaluation Regarding Misaligned Separators in LCR-25 Standby Batteries, Revision 1 - Original Letter Did Not Include the List of Affected Utilities | |
ML14261A150 | 17 September 2014 | Interim Report to the NRC of 10 CFR 21 Event 50285, Reported by Itt 07/18/14 Concerning M1 Diaphragms, Customer Testing | |
ML14210A007 | 18 July 2014 | Part 21 Report - Cracking in KCR-13 Standby Battery Jars | |
ML14212A401 | 18 July 2014 | Final Report - 10 CFR Part 21 Evaluation Regarding Cracking in KCR-13 Standby Battery Jars | |
ML14134A122 | 9 May 2014 | Notification of Potential Part 21 Report - Cracking in KCR-13 Standby Battery Jars | |
ML14139A017 | 28 April 2014 | Updated Interim Report - Inability to Complete 10CFR Part 21 Evaluation Regarding Cracking in KCR-13 Standby Battery Jars | |
ML14303A526 | 28 March 2014 | Interim Part 21 Report - Misaligned Separators in LCR-25 Standby Batteries | |
ML14063A434 | 24 February 2014 | Part 21 Report - Cracking in KCR-13 Standby Battery Jars | |
ML14034A189 | 23 January 2014 | Part 21 - Loose Battery Vent Assemblies | Commercial Grade Dedication |
ML14006A005 | 20 December 2013 | Cracking in KCR-13 Standby Battery Jars | |
ML13358A306 | 20 December 2013 | Interim Report - Inability to Complete 10CFR Part 21 Evaluation Regarding Cracking in KCR-13 Standby Battery Jars | |
ML13238A253 | 21 August 2013 | Notification of Potential Part 21 Report - Foxboro Power Supply Potential Failures Due to Defective the Wraps and Holders | |
ML13165A342 | 12 June 2013 | 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers | |
ML13093A153 | 2 April 2013 | Part 21 Report - Foxboro Power Supply Potential Failures Due to Defective Tie Wraps and Holders | |
ML13095A011 | 25 March 2013 | Update to Event Number 48798: 10 CFR Part 21 Notification, Dual Alarm Modules and Single Alarm Modules | |
ML13063A443 | 1 March 2013 | 10 CFR Part 21 Report Notification, Dual Alarm Modules and Single Alarm Modules | |
ML13064A012 | 25 February 2013 | Notification of Potential Part 21 Report Re Wedge Pin Failure of an Anchor/Darling Double-Disc Gate Valve | Anchor Darling |
ML12352A123 | 13 December 2012 | 60-Day Interim Report Involving an Evaluation of a Design Change to Magne-Blast Circuit Breakers | |
ML12348A136 | 13 December 2012 | Part 21 60-Day Interim Report Notification: Adequacy of Design Change in Am Magne-Blast Circuit Breakers | |
ML12318A041 | 8 November 2012 | Part 21 Report - Commercial Grade Dedication Not Properly Applied to Butterfly Valves | Commercial Grade Dedication Condition Adverse to Quality |
ML12094A371 | 2 April 2012 | Part 21 Report - Rosemount Pressure Transmitters with Nonzero Based Calibrations | |
ML11228A086 | 1 August 2011 | Submittal of 10CFR21 Reporting of Defects and Non-Compliance - Engine Systems, Inc. Report No. 10CFR21-0102, Rev. 0, Air Start Motors with Friction-Clutch Inertia Drives | |
ML103060102 | 29 October 2010 | Notification of Potential Part 21 Transfer of Information Concerning Control Components Inc. (CCI) Drag Valves | Boric Acid |
ML101720486 | 16 June 2010 | Part 21 Notification - Tyco Electronic Relay Recall | |
ML092680246 | 23 September 2009 | Notification of Potential Part 21 on Reportable Occurrence Under 10 CFR Part 21: Firmware Anomaly in the Model RM-80 Radiation Monitoring System | Overexposure |
ML091490488 | 28 May 2009 | Notification of Potential Part 21 Report Re Air Circuit Breaker Deficiency | |
ML090410485 | 6 February 2009 | Notification of Potential Part 21 Report (Draft) Re Defective ASME SA-193, Grade 6 Cap Screw Material | |
ML090400748 | 5 February 2009 | Update to Part 21 Report Notification, Texas Instruments Operational Amplifier, P/N: OPA 2111 | |
ML090350217 | 27 January 2009 | Notification of Potential Part 21 Report from Fisher Controls International - Water Quality Deficiency | |
ML083190017 | 12 November 2008 | Notification of Potential Part 21 on All Dimensionally Verified Commercial Grade Items Processed Per Fisher Manufacture Procedure Fmp 2K28 | Commercial Grade |
ML082390106 | 25 August 2008 | Notification of Potential Part 21 on Failure of F and G Switches | Test box |