 Issue dateTitleTopic
ML18153A14310 June 1997Part 21 Rept Re Possible Machining Defect in Certain Stainless Steel Swagelok Tube Fitting Bodies.Facilities Have Been Notified About Possible Problem
ML20133E8008 January 1997Deficiency Rept Re Nonconformance Related to Masterflow 713 Grout,Which Master Builders,Inc Has Supplied as Nuclear SR Product to 18 Npps.Cause Unknown.Requests That Listed Info Be Provided to Gain Insight as to Scope & Possible Cause
ML20086A27527 June 1995Part 21 Rept Re Several Incidents of Instrument Drift in Excess of Specified Limits for Rosemount Pressure Transmitter Model 1154SH9.Other Licensees Advised to Be Alert to Differences in Pressure Indication
ML18153B08426 September 1994Suppl to 940902 Initial Part 21 Rept Re Defect W/Governor Valves Used in turbine-driven Pumps Mfg by Dresser-Rand to Formally Addresss Written 30 Day Rept Requirement of 10CFR21(c)(3)(ii)
ML18153B0602 September 1994Initial Part 21 Rept Re Steam Drive AFW Pump Governor Valve Mfg by Dresser-Rand.Maint Procedure to Stroke Governor Valve Stem Performed Weekly & Monitoring of Corrosion Build Up in Gland Seal Leakoff Area Performed Weekly
ML20059H77217 January 1994Part 21 Rept Re Virginia Power Notifying Fairbands Morse Via Failure Analysis Rept NESML-Q-058 of Defective Air Start Distributor cam,16104412
ML20059F2637 January 1994Part 21 Rept Re Air Start Distributor Cam Mfg by Fairbanks Morse.Mfg Suggests That Site Referenced in Encl App I Inspect Air Start Distributor Cam as Soon as Practical
ML18153D0813 August 1992Interim Part 21 Rept Re Analysis of Klockner-Moeller Model NZM6-63,480 Volt Circuit Breakers.Initially Reported on 920701.Lever Fracture Should Be Examined to Determine If Any Cleaning Sprays or Purifying Agents Have Been Used
ML18153C1012 February 1990Part 21 Rept Re Two of Three Pc Cards in GE Type SLV11A1 Over/Undervoltage Relays Failing to Produce Output.Short Between Leads Would Result in Damage to Component 1C5. Sketch of Threshold Detection Board Encl
ML20005G6835 January 1990Part 21 Rept Re Installation Instructions for Grommet Use Range for Patel Conduit Seal P/N 841206.Conduit Seals in Environ Qualification Applications Inspected for Proper Wire Use Range & Grommets Replaced
ML20247D30112 July 1989Part 21 Rept 10CFR21-0047 Re Control Wiring Insulation of Inner Jacket Used on General Motors Diesel Generator Sets Identified as 999 or MP Series.Encl List of Owners of Units Notified
ML20207N46412 October 1988Part 21 Rept Re Potential Problem W/Emd 20-645E4,Type 999 Excitation Sys Circuit Breaker & Wiring.Potential for Field Circuit Breaker to Trip Due to Combined Air Temps & Field Current Exists at All Plants W/Model 999 Sys
ML20205F32110 October 1988Part 21 Rept Re Potential Deviation from Tech Spec Concerning Ry Indicators Due to Operating Temp Effect on Analog Meter Movement.Initially Reported on 881006.Customers Verbally Notified on 881006-07
ML20207T80620 February 1987Part 21 & Deficiency Rept Re Defect in Recirculation Spray Hxs.Initially Reported on 870218.Original HX Design Did Not Consider External Pressurization of Diaphragm Seal Plate W/O Presence of Internal Pressure as Balance.Mods Scheduled
ML20214M3184 September 1986Potential Part 21 Rept Re Contromatics Actuator W/Jackscrew/ Handwheel Emergency Override Operator.Jackscrew/Handwheel Should Be Used for Emergency Manual Operation Only.Encl Ltr Also Sent to Listed Utils/Ae Firms
ML20206S08430 June 1986Part 21 Rept Re Possible Cut Wires in Wire Harness of Bbc Brown Boveri K600/K800 Circuit Breakers.Initially Reported on 860509.Safety Implications Listed.Gear Guard Designed to Prevent Cut Wires
ML20197J63712 May 1986Part 21 Rept Re Possibility of Power Supply hang-up When Energizing Slv Relays.Changes Made in Power Supply Circuitry.Slv Relays,W/Mods Incorporated in Latest Designs, Extensively Tested W/O Power Supply Failures
ML20137X38927 February 1986Part 21 Rept Re Possible Defect in Model KMG-HRH Noble Gas Radiation Monitor W/Enhanced Detector Model KDGM-HR. Initially Reported on 860222.Vendor Will Request Utils for Listed Plants to Determine If Monitors Defective
ML20125B1616 June 1985Supplemental Part 21 Rept Re Addl Circuit Breakers,Furnished as Spares,W/Overcurrent Trip Devices That May Have Short Time Delay Band Lever.Items Require Insp & Replacement If Link Found Incorrect
ML20127N06213 May 1985Part 21 Rept Re Incorrect Short Time Delay Band Lever Inadequately Installed in Low Voltage K-line Circuit Breaker Electromechanical Overcurrent Trip Device.Visual Insp to Determine If Correct Lever Installed Recommended
RBG-18701, Attachment of Final Deficiency Rept DR-138 Re ITE-Gould Type 2150 Overload Relays Out of Calibr.Relays Sent Back & Replaced w/L10 Overload Relays.Response to Request for Addl Info Re Surry & North Anna SPDS Encl20 August 1984Attachment of Final Deficiency Rept DR-138 Re ITE-Gould Type 2150 Overload Relays Out of Calibr.Relays Sent Back & Replaced w/L10 Overload Relays.Response to Request for Addl Info Re Surry & North Anna SPDS EnclSafe Shutdown
ML20088A62328 March 1984Part 21 Rept Re Abnormal Wear on Linear Converter Units Mfg & Furnished to Power Generating Facilities.Caused by Actuator Hunting.All Customers Provided Field Lubrication Procedure
ML20081C5119 March 1984Part 21 Rept Re Status Update Concerning Abnormal Wear on Linear Converters.Test Program Underway.Results of Investigation Indicate Excessive Wear Caused by Hunting of Control Circuitry
ML20087P7958 March 1984Interim Part 21 Rept Re Linear Converters Furnished by Pacific Air Products.Initially Reported on 840213.Vendor Investigation of Possible Causes of Excessive Wear Underway. Next Rept by 840730
ML20086L09230 January 1984Part 21 Rept Re Linear Converter Device W/Possible Generic Defect.Initially Reported on 840116.Written Notifications Issued.Customer Responses Should Be Received by 840331.Final Rept Will Be Submitted by 840430
ML20086L09817 January 1984Part 21 Rept Re Linear Converter Device W/Possible Generic Defect.Initially Reported on 840116.Preliminary Analysis Indicates Excessive Wear of Brass Shaft Guides.Next Rept Will Be Submitted within 90 Days.Supporting Info EnclBoric Acid
ML20072N9898 July 1983Interim Part 21 Rept Confirming 830705 Telcon Re Anomalies in Artificially Aged Apparatus (Using Ahrrenius Methodology W/Elevated Temp Aging).Deficiency Found During Qualification Testing for IEEE 323-1974.Draft Notices Encl
ML20010C73212 August 1981Part 21 Rept Re Incompatibility Between Crosby 6X10 & 8X10 Safety Relief Valve Solenoids.Vendor Will Inspect Assemblies Using Stricter Acceptance Criteria
ML18139B18311 March 1981Part 21 Rept,Originally Reported 790525,re Steam Generator Feet Bolt Hole Discrepancies.Corrosion Removed.Rusted & Galled Threads Cleaned by Running Helicoil Tap Into Bolt Holes Prior to New Helicoil Installation
ML18139A87319 November 1980Part 21 Rept Re S&W Notification That out-of-phase Transfer Might Occur When Emergency Buses Are Transferred from Offsite Power Source to Emergency Diesel Generators After Reaching Rated Speed & Voltage.Originally Reported 801114
ML19320D1952 July 1980Part 21 Rept Re Existence of Nonconservative Assumption in Cold Shutdown Design Basis Boron Dilution Accident Analysis in Fsar.Caused by Use of Incorrect Sys Vol.Review Will Be Performed to Identify & Analyze Addl Accidents
ML18114A69414 June 1979Failure of Solenoid Operated Valves to Meet IE Bulletin 79-01 Environ Qualification Requirements.Environmentally Unqualified Valves Have Been or Will Be Replaced